Attach Safety Cables

Each ColorBlaze TRX fixture is designed for use with safety cables to tether
fixtures to secure anchor points. When suspending or installing ColorBlaze TRX
fixtures overhead, or when dictated by local or state code or advised by a structural
engineer, loop safety cables through the restraining holes located at the either end of
the ColorBlaze TRX housing. Securely anchor the safety cables using a method that
follows code or engineer's requirements.

Connect Data and Power

Make sure the power is OFF before connecting ColorBlaze TRX fixtures.
1. Supply power to the first ColorBlaze TRX fixture in a series by plugging a power
cable with Neutrik PowerCon connector into the blue Power In port on the input
side of the fixture.
3
4
2
5
1
20
ColorBlaze TRX
Product Guide
(Optional)
From line power
Safety cable minimum requirements
Material
316 Stainless Steel
5/64 to 3/16 in (2 to 5 mm) nominal
Size
diameter. Minimum break load must be
greater than 400 lb (181 kg)
Construction
7 x 7 (49 wires) preformed stranded