Technibel MCAF92R5TA Technical Data & Service Manual page 9

Split system air conditioner indoor unit
Table of Contents

Advertisement

MCAF122R5TA-
Controller PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ....... Dia. and lenght
Fan motor model...Q'ty
No. Of poles...rpm (230 V, Hi)
Nominal output
Coil resistance (Ambient temp. 20 °C )
Safety devices
Run capacitor
Flap Motor
Type
Model
Rating
Coil resistance (Ambient temp. 25 °C )
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
Type
Operating temp. Open
Close
mm
W
°C
µF
VAC
Aluminium plate fin / Copper tube
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE
9
WSA
Microprocessor
250 V - 3,15 A
RC-2 (RC)
Cross - flow
1.... Ø 95 / L 617
KFV4Q-11H5P-S...1
4...1250
10
BRN-WHT: 561,8
VLT-WHT: 197,4
VLT-ORG: 63,4
YEL-ORG: 155,7
YEL-PNK: 115,9
internal fuse
145 ± 5
-
1
450
Stepping motor
MP24GA1
DC 12 V
380 ± 7%
2
1,4
0,13