5-8 Cold Draft Prevention (Heating)

This function controls indoor fan speed so a strong draft of cold air will not blow out before the indoor heat
exchange coil have sufficiently warmed up.
When 10 minutes has elapsed, the fan speed is automatically switched to set speed regardless of indoor heat
exchange coil temperature.
indoor heat exchange
coil temp. (°C)
NOTE
The operation temperature shown as Tc in the chart differ by models.
7H
Tc
32
max.10 minutes
Tc
indoor fan
9H
12H
32
34
off
25
set speed