PCG10 / K8016
Connection
Connect the unit to the printer port LPT1, LPT2 or LPT3.
A Velleman PC scope can be connected to the "To PC Scope" connector.
To select the LPT port address click Hardware Setup on Options menu of the
oscilloscope window, or run Pc-Lab2000 software.
Connect the mains voltage DC adapter to the unit : 12VDC / 800mA. (pin =
positive).
M
ATTENTION: Only use adapter with correct voltage otherwise the unit could
be damaged.
Using a wrong power supply could blow the internal fuse. The fuse is
soldered onto the PCB, please contact an experienced service center, to
replace the fuse. The best way is to cut the leads of the fuse , and to solder a
new (1A PICO) fuse onto the old leads.
After starting the software (see also getting started manual), the LED on the
front panel should lid.