DTA-SDH/155 Operating Manual 1. Instrument Profile 1.1. Physical Characteristics This chapter introduces various major parts of DTA-SDH/155 so that you can know the appearance and overall structure of the instrument. Façade Figure 1-1 DTA-SDH/155 Profile Shineway Technologies, Inc.
Page 5
DTA-SDH/155 Operating Manual Figure 1-2 Top View (1) Electrical adapter port; (2) BNC input joint for external clock; (3) Standard USB port; (4) BNC joint of output port; (5) BNC joint of input port; (6) SFP port for opticalinput/output. Shineway Technologies, Inc.
Page 6
DTA-SDH/155 Operating Manual Figure 1-3 Façade View (1) Fastening metal buckle of the belt; (2) Color LCD screen; (3)LED pointer light; : Instrumentation Power on instructions; : Instrumentation external power supply instructions; Note: In order to ensure the performance and battery life, please use the first three put the battery completely discharge and recharge 12-14 hours, After 4-6 hours per charge achieved.
Operating Manual Figure 1-4 Back View (1) Back bracket of the instrument; (2) Battery cabin. 1.2. Introduction to Graphical User Interface This chapter introduces the graphical user interface (GUI) of DTA-SDH/155. ⑴ ⑵ ⑶ Figure 1-5 Graphical User Interface (1) Information prompt area: including the error, alarm, insert error, running prompt and electric...
DTA-SDH/155 Operating Manual quantity of battery; (2) Main display area: the display of various functions, setup and test results of the instrument; (3) Function key area: different function keys in different interfaces to realize the operation of the instrument; (4)Language select.
DTA-SDH/155 Operating Manual “Load”—load a stored configuration file as in Figure 2-3 Configuration File: Figure 2-3 Configuration File Click ”Load” to pop up a stored configuration file, select a file name and confirm. In this case, configuration parameters are the contents of a selected configuration file. Press “Set” to make the configuration valid.
DTA-SDH/155 Operating Manual 2.1.1. SDH Path Mode (Default Mode of the Manufacturer) For the structure chart, see Figure 2-5 as follows: Figure 2-5 SDH Path Mode 2.1.2. SDH Demux Mode For the structure chart, see Figure 2-6 as follows: Figure 2-6 SDH Path Demux Mode 2.1.3.
DTA-SDH/155 Operating Manual 2.1.4. SDH Monitor Mode For the structure chart, see Figure 2-8 as follows: Figure 2-8 SDH Monitor Mode 2.1.5. SDH Through Mode For the structure chart, see Figure 2-9 as follows: Figure 2-9 SDH Through Mode 2.1.6. PDH Path Mode...
DTA-SDH/155 Operating Manual Figure 2-11 PDH Monitor Mode 2.1.8. PDH Span Mode For the structure chart, see Figure 2-12 as follows: Figure 2-12 PDH Span Mode 2.1.9. PDH Through Mode For the structure chart, see Figure 2-13 as follows: Figure 2-13 PDH Through Mode 2.2.
DTA-SDH/155 Operating Manual Figure 2-14 Physical Interface Setup 2.2.2. Receiving Gain The instrument supports receiving gain at two levels including 0dB and 18dB. See Figure 2-15 as follows: Figure 2-15 Receiving Gain Setup 2.2.3. Mapping The mapping and de-mapping modes: E1 (unframed, CCS, CCS/CRC, CAS & CAS/CRC), E3 (unframed/frame), E4 (unframed/frame), C-12 (KLM optional), C-3 (TUG3 optional), C-4.
DTA-SDH/155 Operating Manual Figure 2-18 Clock Setup 2.3. LED Interface LED interface comprises SDH interface and TCM interface, of which SDH interface includes all alarms and errors of PDH. 2.3.1. SDH Interface For the interface, see Figure 2-19 as follows:...
Page 16
DTA-SDH/155 Operating Manual LTC: loss of external clock RS: related to regenerator section LOF: loss of frame alignment (6) OOF: frame alignment (5) EFAS: frame alignment (1-4) TIM: trace identifying mark mismatch of regenerator section B1: error code monitoring of regenerator section, and BIP8 check error...
DTA-SDH/155 Operating Manual 3.1. Tests Summary For tests summary interface, see Figure 3-2 as follows: Figure 3-2 tests summary “Start time” refers the time of the system when ”Start” shortcut key is clicked on. “Duration” refers to the continual time keeping after “Start time”. Click the exit button to stop.
DTA-SDH/155 Operating Manual Figure 3-6 G.829 Analyzer Interface M.2101 including: MS, HOPOH, LOPOH; and interface indicators including EB, BE, BER, ES, ESR, SES, SESR, UAS, UASR, SEP, SEPR. See Figure 3-7 as follows: Figure 3-7 M.2101 Analyzer Interface 3.3.2. PDH Part Error performance analyser of PDH including: G.821, G.826, M.2100.
Page 22
DTA-SDH/155 Operating Manual Figure 3-8 G.821 Analyzer Interface G.826 interface indicators including EB, BBE, BBER, ES, ESR, SES, SESR, UAS, UASR as in Figure 3-9: Figure 3-9 G.826 Analyzer Interface M.2100 interface indicators including BE, BER, ES, ESR, SES, SESR, UAS and UASR. See Figure 3-10 as follows: Figure 3-10 M.2100 Analyzer Interface...
Page 23
DTA-SDH/155 Operating Manual In the performance analyzer interface in above, click on the “Chart” function key to display various results in a chart as in Figure 3-11: Figure 3-11 Result Chart In any interface, click on ”Start” shortcut key to start the synchronous counting and operation.
DTA-SDH/155 Operating Manual 4.2. Regular Overhead Test Including HOPOH and LOPOH. See Figure 4-3 as follows: Figure 4-3 Regular Overhead Test The contents include the transmission and receiption of S1, G1, H4, V5, K1, K2, K3, K4 and C2. The ”Set” shortcut key can set up an input value or parameter of “Transmit value”. “Receive value”...
DTA-SDH/155 Operating Manual “Receive value of pointer“: receive in real time. The ”Set” shortcut key can set up the input value or parameter for “Pointer type”, “NDF, “Setup SS BITS” and “Transmit value of pointer“. “Receive value of pointer“ is not controlled by the shortcut key and can receive in real time.
DTA-SDH/155 Operating Manual 4.5. Error Insert Test For error insert test, see Figure 4-6 as follows: Figure 4-6 Error Insert Test “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. After the running start, the start button changes to the exit button.
DTA-SDH/155 Operating Manual 4.6. Insert Alarm For insert alarm, see Figure 4-7 as follows: Figure 4-7 Insert Alarm “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the exit button to stop.
Page 29
DTA-SDH/155 Operating Manual Figure 4-8 Pointer Adjusting Test “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the “Start” shortcut key again to stop.
DTA-SDH/155 Operating Manual 5. Function Test Function test including: APS test, transparency test, TCM test, RTD test and tributary scan test. See Figure 5 -1 as follows: Figure 5 -1 Function Test 5.1. APS Test For APS test, eee Figure 5 -2 as follows: Figure 5 -2 APS Test “Trigger”: MS-AIS, AU-AIS, TU-AIS, B1, and B2, with a default value of MS-AIS.
DTA-SDH/155 Operating Manual 5.2. Data Path (Transparency) Test For data path test, see Figure 5 -3 as follows: Figure 5 -3 Transparency Test “Trans OH”: D1-D3, D4-D12, E1, E2, F1 and None, with a default value of None. “Trans Pat”: 2E11, 2E15, 2E20 and 2E23, with a default value of 2E11.
DTA-SDH/155 Operating Manual “Err Mode”: Rate (default parameter)—1.0E-3, 1.0E-4, 1.0E-5, 1.0E-6, 1.0E-7, 1.0E-8 and 1.0E-9, with a default value of 1.0E-3. Outburst—scope of setup 0-8000, with a default value of 2000. Repetitive burst—scope of setup 0-8000, with a default value of 2000.
DTA-SDH/155 Operating Manual “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the “Exit” shortcut key to stop. “Current”: indicating the measuring result of current RTD.
DTA-SDH/155 Operating Manual 6. Test Result The test result includes alarm test result, error code test result, pointer test result, overhead test result, TCM test result, transparency test result, frequency test result and tributary test result, with the interface as in Figure 6-1. All test result menus have a save function. Click on the “Save“...
DTA-SDH/155 Operating Manual Pat AIS and Pat LSS. (Only in E1 mode) SDH part: including LOS, LOF, RS TIM, MS AIS, MS RDI, AU AIS, AU LOP, HP UNEQ, HP RDI, HP TIM, HP PLM, LTI, Pat AIS, Pat LSS, TU AIS (grey when set up as C4), TU LOP (grey when set up as C4), LP UNEQ (grey when set up as C4), LP RDI (grey when set up as C4), RFI (grey when set up as C3 or C4), LP TIM (grey when set up as C4) and LP PLM (grey when set up as C4).
DTA-SDH/155 Operating Manual Figure 6-4 Pointer Test Result Pointer test result including: pointer value and SS BITS value of AU and TU, and counting and rate of +AUP JE, -AUP JE, AU NDF, AU INV, +TUP JE, -TUP JE, TU NDF and TU INV.
DTA-SDH/155 Operating Manual once in the interface. Click on the ”Stop” button to stop. 6.5. TCM Test Result For TCM test result interface, see Figure 6-6 as follows: Figure 6-6 TCM Test Result The display of the number, error code sec and rate of TC-REI, TC-OEI and IEC of N1 and N2 in the overhead of high-order &...
DTA-SDH/155 Operating Manual once in the interface. Click on the ”Stop” button to stop. 6.7. Frequency Test Result For frequency test result, see Figure 6-8 as follows: Figure 6-8 Frequency Test Result “Rev Pat”: PRBS code pattern of the receiving part in setup menu.
Page 39
DTA-SDH/155 Operating Manual The display of tributary scan results of VC12 (E1), VC3 (E3) and VC4 (E4) (specified according to setup mode of the receiving part in setup menu) is available. Real-time reception and display are available once in the interface. Click on the “Stop” button to stop.
DTA-SDH/155 Operating Manual 7. System Setup For the main item of system setup, see Figure 7-1 as follows: Figure 7-1 System Setup 7.1. File Management The file management includes configuration file and result file as in Figure 7-2. Figure 7-2 File Management 7.1.1.
DTA-SDH/155 Operating Manual Figure 7-3 Configuration File Result File 7.1.2. Ten test results are available as in Figure 7-4: Figure 7-4 Result Test Interface 7.2. Version Information View the version information of the current software and hardware as in Figure 7-5 as follows: Figure 7-5 Version information Shineway Technologies, Inc.
DTA-SDH/155 Operating Manual 7.3. Recover Default Recover the system to the default setup as in Figure 7-6: Figure 7-6 Default Recovery 7.4. Time Setup Set up the time of system as in Figure 7-7: Figure 7-7 Time Setup “Date”: YYYY—2000-2030, MM—1-12, DD—1-31.
DTA-SDH/155 Operating Manual Figure 7-8 Touch Screen Calibration Interface 7.6. Other Setup See Figure 7-9 as follows: Figure 7-9 Other Setup Interface “Save Mode”: manual save, save once error interval, and timing save, with a default value of ”Manual”. “Save duration”: 5 minute, 15 minute, 30 minute and 1 hour, with a default value of “5minute”.
Figure 7-11 as follows: Figure 7-11 Terminal Wiring Diagram Contacting Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service.
Page 45
DTA-SDH/155 Operating Manual THANK YOU FOR CHOOSING SHINEWAY TECHNOLOGIES! Shineway Technologies, Inc.