    DTA-SDH/155 Operating Manual Instrument Profile ..........................4 1.1. Physical Characteristics ......................4 1.2. Introduction to Graphical User Interface ................. 7 Test Configuration ..........................8 2.1. Test Mode ..........................9 2.1.1. SDH Path Mode (Default Mode of the Manufacturer) ............ 10 2.1.2.
  • Page 3 DTA-SDH/155 Operating Manual 7.2. Version Information ....................... 41 7.3. Recover Default........................42 7.4. Time Setup ..........................42 7.5. Touch Screen Calibration ...................... 42 7.6. Other Setup ........................... 43 7.7. Performance Objectives ......................43 7.8. USB Connection ........................44 Shineway Technologies, Inc.
  • Page 4: Instrument Profile

    DTA-SDH/155 Operating Manual 1. Instrument Profile 1.1. Physical Characteristics This chapter introduces various major parts of DTA-SDH/155 so that you can know the appearance and overall structure of the instrument. Façade Figure 1-1 DTA-SDH/155 Profile Shineway Technologies, Inc.
  • Page 5 DTA-SDH/155 Operating Manual Figure 1-2 Top View (1) Electrical adapter port; (2) BNC input joint for external clock; (3) Standard USB port; (4) BNC joint of output port; (5) BNC joint of input port; (6) SFP port for opticalinput/output. Shineway Technologies, Inc.
  • Page 6 DTA-SDH/155 Operating Manual Figure 1-3 Façade View (1) Fastening metal buckle of the belt; (2) Color LCD screen; (3)LED pointer light; : Instrumentation Power on instructions; : Instrumentation external power supply instructions; Note: In order to ensure the performance and battery life, please use the first three put the battery completely discharge and recharge 12-14 hours, After 4-6 hours per charge achieved.
  • Page 7: Introduction To Graphical User Interface

    Operating Manual Figure 1-4 Back View (1) Back bracket of the instrument; (2) Battery cabin. 1.2. Introduction to Graphical User Interface This chapter introduces the graphical user interface (GUI) of DTA-SDH/155. ⑴ ⑵ ⑶ Figure 1-5 Graphical User Interface (1) Information prompt area: including the error, alarm, insert error, running prompt and electric...
  • Page 8: Test Configuration

    DTA-SDH/155 Operating Manual quantity of battery; (2) Main display area: the display of various functions, setup and test results of the instrument; (3) Function key area: different function keys in different interfaces to realize the operation of the instrument; (4)Language select.
  • Page 9: Test Mode

    DTA-SDH/155 Operating Manual “Load”—load a stored configuration file as in Figure 2-3 Configuration File: Figure 2-3 Configuration File Click ”Load” to pop up a stored configuration file, select a file name and confirm. In this case, configuration parameters are the contents of a selected configuration file. Press “Set” to make the configuration valid.
  • Page 10: Sdh Path Mode (Default Mode Of The Manufacturer)

    DTA-SDH/155 Operating Manual 2.1.1. SDH Path Mode (Default Mode of the Manufacturer) For the structure chart, see Figure 2-5 as follows: Figure 2-5 SDH Path Mode 2.1.2. SDH Demux Mode For the structure chart, see Figure 2-6 as follows: Figure 2-6 SDH Path Demux Mode 2.1.3.
  • Page 11: Sdh Monitor Mode

    DTA-SDH/155 Operating Manual 2.1.4. SDH Monitor Mode For the structure chart, see Figure 2-8 as follows: Figure 2-8 SDH Monitor Mode 2.1.5. SDH Through Mode For the structure chart, see Figure 2-9 as follows: Figure 2-9 SDH Through Mode 2.1.6. PDH Path Mode...
  • Page 12: Pdh Span Mode

    DTA-SDH/155 Operating Manual Figure 2-11 PDH Monitor Mode 2.1.8. PDH Span Mode For the structure chart, see Figure 2-12 as follows: Figure 2-12 PDH Span Mode 2.1.9. PDH Through Mode For the structure chart, see Figure 2-13 as follows: Figure 2-13 PDH Through Mode 2.2.
  • Page 13: Receiving Gain

    DTA-SDH/155 Operating Manual Figure 2-14 Physical Interface Setup 2.2.2. Receiving Gain The instrument supports receiving gain at two levels including 0dB and 18dB. See Figure 2-15 as follows: Figure 2-15 Receiving Gain Setup 2.2.3. Mapping The mapping and de-mapping modes: E1 (unframed, CCS, CCS/CRC, CAS & CAS/CRC), E3 (unframed/frame), E4 (unframed/frame), C-12 (KLM optional), C-3 (TUG3 optional), C-4.
  • Page 14: Prbs Code Pattern

    DTA-SDH/155 Operating Manual Figure 2-16 Mapping Mode Setup 2.2.4. PRBS Code Pattern For the setup interface of test code pattern, see Figure 2-17 as follows: Figure 2-17 Test Code Pattern Setup Options for test code pattern: 2E23, 2E23 (INV), 2E20, 2E20 (INV), 2E15, 2E15 (INV), 2E11, 2E11 (INV), 2E9, 2E9 (INV), 1111 and 0101.
  • Page 15: Led Interface

    DTA-SDH/155 Operating Manual Figure 2-18 Clock Setup 2.3. LED Interface LED interface comprises SDH interface and TCM interface, of which SDH interface includes all alarms and errors of PDH. 2.3.1. SDH Interface For the interface, see Figure 2-19 as follows:...
  • Page 16 DTA-SDH/155 Operating Manual LTC: loss of external clock RS: related to regenerator section LOF: loss of frame alignment (6) OOF: frame alignment (5) EFAS: frame alignment (1-4) TIM: trace identifying mark mismatch of regenerator section B1: error code monitoring of regenerator section, and BIP8 check error...
  • Page 17: Tcm Interface

    DTA-SDH/155 Operating Manual REI: remote error indication of low-order path RDI: remote defect indication of low-order path PLM: payload mismatch alarm of low-order path TIM: trace identifying mark mismatch of low-order path LOM: loss of multiframe RFI: remote failure indication of low-order path...
  • Page 18: Error Performance Analyzer

    DTA-SDH/155 Operating Manual LTC: TCM frame loss alarm RDI: TCM remote defect alarm ODI: TCM output defect alarm TIM: TCM trace mismatch REI: TCM remote error alarm OEI: TCM output error alarm AIS: TCM alarm indication signal IEC: TCM input error counting...
  • Page 19: Tests Summary

    DTA-SDH/155 Operating Manual 3.1. Tests Summary For tests summary interface, see Figure 3-2 as follows: Figure 3-2 tests summary “Start time” refers the time of the system when ”Start” shortcut key is clicked on. “Duration” refers to the continual time keeping after “Start time”. Click the exit button to stop.
  • Page 20: Error Performance Analyser

    DTA-SDH/155 Operating Manual 3.3. Error Performance Analyser 3.3.1. SDH Part Error performance analyzer of SDH part including: G.826, G.828, G.829 and M.2101. G.826 including: MS, HOPOH, LOPOH; and interface indicators including EB, BBE, BBER, ES, ESR, SES, SESR, UAS, UASR. See Figure 3-4 as follows: Figure 3-4 G.826 Analyzer Interface...
  • Page 21: Pdh Part

    DTA-SDH/155 Operating Manual Figure 3-6 G.829 Analyzer Interface M.2101 including: MS, HOPOH, LOPOH; and interface indicators including EB, BE, BER, ES, ESR, SES, SESR, UAS, UASR, SEP, SEPR. See Figure 3-7 as follows: Figure 3-7 M.2101 Analyzer Interface 3.3.2. PDH Part Error performance analyser of PDH including: G.821, G.826, M.2100.
  • Page 22 DTA-SDH/155 Operating Manual Figure 3-8 G.821 Analyzer Interface G.826 interface indicators including EB, BBE, BBER, ES, ESR, SES, SESR, UAS, UASR as in Figure 3-9: Figure 3-9 G.826 Analyzer Interface M.2100 interface indicators including BE, BER, ES, ESR, SES, SESR, UAS and UASR. See Figure 3-10 as follows: Figure 3-10 M.2100 Analyzer Interface...
  • Page 23 DTA-SDH/155 Operating Manual In the performance analyzer interface in above, click on the “Chart” function key to display various results in a chart as in Figure 3-11: Figure 3-11 Result Chart In any interface, click on ”Start” shortcut key to start the synchronous counting and operation.
  • Page 24: Event Record

    DTA-SDH/155 Operating Manual 4. Event Record Event record interface including: trace overhead test, regular overhead test, pointer value test, pointer sequence test, error insert test, insert alarm, pointer adjusting test as in Figure 4-1. Figure 4-1 Event Record Interface 4.1. Trace Overhead Test Trace overhead test includes HOPOH (J0, J1) &...
  • Page 25: Regular Overhead Test

    DTA-SDH/155 Operating Manual 4.2. Regular Overhead Test Including HOPOH and LOPOH. See Figure 4-3 as follows: Figure 4-3 Regular Overhead Test The contents include the transmission and receiption of S1, G1, H4, V5, K1, K2, K3, K4 and C2. The ”Set” shortcut key can set up an input value or parameter of “Transmit value”. “Receive value”...
  • Page 26: Pointer Sequences Test

    DTA-SDH/155 Operating Manual “Receive value of pointer“: receive in real time. The ”Set” shortcut key can set up the input value or parameter for “Pointer type”, “NDF, “Setup SS BITS” and “Transmit value of pointer“. “Receive value of pointer“ is not controlled by the shortcut key and can receive in real time.
  • Page 27: Error Insert Test

    DTA-SDH/155 Operating Manual 4.5. Error Insert Test For error insert test, see Figure 4-6 as follows: Figure 4-6 Error Insert Test “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. After the running start, the start button changes to the exit button.
  • Page 28: Insert Alarm

    DTA-SDH/155 Operating Manual 4.6. Insert Alarm For insert alarm, see Figure 4-7 as follows: Figure 4-7 Insert Alarm “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the exit button to stop.
  • Page 29 DTA-SDH/155 Operating Manual Figure 4-8 Pointer Adjusting Test “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the “Start” shortcut key again to stop.
  • Page 30: Function Test

    DTA-SDH/155 Operating Manual 5. Function Test Function test including: APS test, transparency test, TCM test, RTD test and tributary scan test. See Figure 5 -1 as follows: Figure 5 -1 Function Test 5.1. APS Test For APS test, eee Figure 5 -2 as follows: Figure 5 -2 APS Test “Trigger”: MS-AIS, AU-AIS, TU-AIS, B1, and B2, with a default value of MS-AIS.
  • Page 31: Data Path (Transparency) Test

    DTA-SDH/155 Operating Manual 5.2. Data Path (Transparency) Test For data path test, see Figure 5 -3 as follows: Figure 5 -3 Transparency Test “Trans OH”: D1-D3, D4-D12, E1, E2, F1 and None, with a default value of None. “Trans Pat”: 2E11, 2E15, 2E20 and 2E23, with a default value of 2E11.
  • Page 32: Rtd Test

    DTA-SDH/155 Operating Manual “Err Mode”: Rate (default parameter)—1.0E-3, 1.0E-4, 1.0E-5, 1.0E-6, 1.0E-7, 1.0E-8 and 1.0E-9, with a default value of 1.0E-3. Outburst—scope of setup 0-8000, with a default value of 2000. Repetitive burst—scope of setup 0-8000, with a default value of 2000.
  • Page 33: Tributary Scan Test

    DTA-SDH/155 Operating Manual “Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is continual time keeping after “Start time”. Click on the “Exit” shortcut key to stop. “Current”: indicating the measuring result of current RTD.
  • Page 34: Test Result

    DTA-SDH/155 Operating Manual 6. Test Result The test result includes alarm test result, error code test result, pointer test result, overhead test result, TCM test result, transparency test result, frequency test result and tributary test result, with the interface as in Figure 6-1. All test result menus have a save function. Click on the “Save“...
  • Page 35: Error Code Test Result

    DTA-SDH/155 Operating Manual Pat AIS and Pat LSS. (Only in E1 mode) SDH part: including LOS, LOF, RS TIM, MS AIS, MS RDI, AU AIS, AU LOP, HP UNEQ, HP RDI, HP TIM, HP PLM, LTI, Pat AIS, Pat LSS, TU AIS (grey when set up as C4), TU LOP (grey when set up as C4), LP UNEQ (grey when set up as C4), LP RDI (grey when set up as C4), RFI (grey when set up as C3 or C4), LP TIM (grey when set up as C4) and LP PLM (grey when set up as C4).
  • Page 36: Overhead Test Result

    DTA-SDH/155 Operating Manual Figure 6-4 Pointer Test Result Pointer test result including: pointer value and SS BITS value of AU and TU, and counting and rate of +AUP JE, -AUP JE, AU NDF, AU INV, +TUP JE, -TUP JE, TU NDF and TU INV.
  • Page 37: Tcm Test Result

    DTA-SDH/155 Operating Manual once in the interface. Click on the ”Stop” button to stop. 6.5. TCM Test Result For TCM test result interface, see Figure 6-6 as follows: Figure 6-6 TCM Test Result The display of the number, error code sec and rate of TC-REI, TC-OEI and IEC of N1 and N2 in the overhead of high-order &...
  • Page 38: Frequency Test Result

    DTA-SDH/155 Operating Manual once in the interface. Click on the ”Stop” button to stop. 6.7. Frequency Test Result For frequency test result, see Figure 6-8 as follows: Figure 6-8 Frequency Test Result “Rev Pat”: PRBS code pattern of the receiving part in setup menu.
  • Page 39 DTA-SDH/155 Operating Manual The display of tributary scan results of VC12 (E1), VC3 (E3) and VC4 (E4) (specified according to setup mode of the receiving part in setup menu) is available. Real-time reception and display are available once in the interface. Click on the “Stop” button to stop.
  • Page 40: System Setup

    DTA-SDH/155 Operating Manual 7. System Setup For the main item of system setup, see Figure 7-1 as follows: Figure 7-1 System Setup 7.1. File Management The file management includes configuration file and result file as in Figure 7-2. Figure 7-2 File Management 7.1.1.
  • Page 41: Result File

    DTA-SDH/155 Operating Manual Figure 7-3 Configuration File Result File 7.1.2. Ten test results are available as in Figure 7-4: Figure 7-4 Result Test Interface 7.2. Version Information View the version information of the current software and hardware as in Figure 7-5 as follows: Figure 7-5 Version information Shineway Technologies, Inc.
  • Page 42: Recover Default

    DTA-SDH/155 Operating Manual 7.3. Recover Default Recover the system to the default setup as in Figure 7-6: Figure 7-6 Default Recovery 7.4. Time Setup Set up the time of system as in Figure 7-7: Figure 7-7 Time Setup “Date”: YYYY—2000-2030, MM—1-12, DD—1-31.
  • Page 43: Other Setup

    DTA-SDH/155 Operating Manual Figure 7-8 Touch Screen Calibration Interface 7.6. Other Setup See Figure 7-9 as follows: Figure 7-9 Other Setup Interface “Save Mode”: manual save, save once error interval, and timing save, with a default value of ”Manual”. “Save duration”: 5 minute, 15 minute, 30 minute and 1 hour, with a default value of “5minute”.
  • Page 44: Usb Connection

    Figure 7-11 as follows: Figure 7-11 Terminal Wiring Diagram Contacting Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service.