Display Power-Up (305); Resolver Reset-To-Preset (307) - Ametek Gemco 2120 Installation Manual

Plc interface module
Table of Contents

Advertisement

Spec Tech Industrial Electric
Chapter 4: Programming
Program Position Offset (302)
13. Select the function key.
(F)
The monitor displays "F----".
302
14. Select function number 302 (Position Offset Function). Select the enter key.
The monitor displays the current position.
Enter desired
reading
15. Enter the actual or desired machine position reading. Select the enter key.
After confi guring the encoder module for use with a resolver, you can proceed
to Section 4.3: Monitor Setup functions.
Display Power Up (305)
This function is used to set what will be displayed on Power Up.
16. Select the function key.
(F)
The monitor displays "F----".
305
17. Select function number 305 (Power Up Function). Select the enter key.
The monitor displays 0 or 1.
0 = Power Up Displaying Position
Enter 0 or 1
1 = Power Up Displaying RPM
18. Enter 0 or 1. Select enter key.

Resolver Reset-to-Preset (307)

The reset-to-preset input is an edge sensitive input that resets position data to a preprogrammed
value. An open collector sinking device or dry contact applied to these terminals activates
the input.
(F)
19. Select the function key.
The monitor displays "F----".
307
20. Select function number 307 (Resolver Reset-to-Preset). Select the enter key.
The monitor displays current value.
26
Spec Tech Industrial Electric
www.spectechind.com
Installation and Programming Manual
www.spectechind.com
888-773-2832
888-773-2832