Download Print this page

Equipment Check - Flowserve Durametallic P-200 Installation Instructions Manual

Cartridge dual pusher seal for standard and big bore ansi pumps

Advertisement

Description
This P-200 seal is a dual, cartridge mounted, end face mechanical seal,
designed for ease of installation. No seal setting dimensions are
required. Removable setting devices provide proper alignment. Installa-
tion according to the following steps will ensure a long
of the P-200 seal.
1

Equipment Check

Follow plant safety regulations prior to equipment disassembly:
1.1
• Lock out motor and valves.
• Wear designated personal safety equipment.
• Relieve any pressure in the system.
• Consult plant MSDS files for hazardous material regulations.
Seal Chamber Requirements
Seal housing bore to have 3.2 m
(125 inch) R
Sleeve or shaft finish to be
0.8 m (32 inch) R
2
finish or better.
a
or better.
a
The images of parts shown in these instructions may differ visually from the actual
parts due to manufacturing processes that do not affect the part function or quality.
To first obstruction
Seal housing face to have surface finish
of 1.6 m (63 inch) R
Gland pilot can be at either
of these register locations.
Shaft or sleeve OD
+0.000 mm (+0.000 inch)
-0.050 mm (-0.002 inch)
+0.000 mm (+0.000 inch) API 610/682
-0.025 mm (-0.001 inch)
trouble-free life
Figure 1
finish or better.
a
ASME
DIN/ISO

Advertisement