Download Print this page
Flowserve RO Installation Instructions Manual
Flowserve RO Installation Instructions Manual

Flowserve RO Installation Instructions Manual

Dual pressurized seals

Advertisement

Quick Links

Dual Pressurized Seals
Dual RO, RO-TT, PTO, PT, RO-PTT,
BRO, BRT, MRO, MRT, and other
component seals
1
Equipment Check
1.1
Follow plant safety regulations prior to equipment disassembly:
1.1.1
Wear designated personal safety equipment
1.1.2
Isolate equipment and relieve any pressure in the system
1.1.3
Lock out equipment driver and valves
1.1.4
Consult plant Safety Data Sheet (SDS) files for hazardous material regulations
1.2
Disassemble equipment in accordance with the equipment manufacturer's instructions
to allow access to seal installation area.
1.3
Remove existing sealing arrangement (mechanical seal or otherwise).
Clean seal chamber and shaft thoroughly.
1.4
Inspect surfaces under gaskets to ensure they are free from pits or scratches. Break all sharp
corners on shaft steps, threads, reliefs, shoulders, key ways, etc. over which gasket(s) must
pass and/or seal against.
1.5
Check shaft or sleeve OD, seal chamber bore, seal chamber depth, gland pilot, stud diameter,
stud bolt pattern and distance to first obstruction to ensure they are dimensionally the same
as shown in the seal assembly drawing.
1.6
Check seal assembly drawings for any modifications (reworks) to be made to the equipment
for mechanical seal installation and act accordingly.
1.7
The equipment must be earthed to prevent sparks due to static electricity discharge.
Experience In Motion
Installation
Instructions

Advertisement

loading

Summary of Contents for Flowserve RO

  • Page 1 Installation Instructions Dual Pressurized Seals Dual RO, RO-TT, PTO, PT, RO-PTT, BRO, BRT, MRO, MRT, and other component seals Equipment Check Follow plant safety regulations prior to equipment disassembly: 1.1.1 Wear designated personal safety equipment 1.1.2 Isolate equipment and relieve any pressure in the system 1.1.3...
  • Page 2 0.10 - 0.15 mm (0.004 - 0.006 inch). If equipment is found outside the general range, contact the equipment manufacturer and your Flowserve representative to verify the equipment’s suitability for the seal. Seal chamber squareness to the shaft centerline should be within 0.0005 mm/mm (0.0005 inch/inch) of seal...
  • Page 3 Be sure that the seal drive pins engage the drive slots in the rotating faces. The RO, PTO, and similar designs have buttoned seal assemblies that can most easily be installed on the shaft or sleeve as a unit with the rotating face gasket O-rings in place in the bore of the rotating faces.
  • Page 4 Be sure that the seal drive ring drive pins engage the drive slots in the seal rings. The RO, PTO, and similar designs have unitized seal assemblies, they can most easily be installed on the shaft or sleeve as a unit with the rotating face gasket O-rings in place in the bore of the rotating face.
  • Page 5 Reassemble the pump. 3. 1 0 See Section 5, Operational Recommendations, before starting pump. Ball Drive Seal Designs The drive ball replaces the set screws in the seal drive and provides the following features: • It compensates for axial shaft adjustment to reset the impeller •...
  • Page 6: Operational Recommendations

    This product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by Flowserve should be used to repair a seal. To order replacement parts, refer to the part code and B/M number. A spare backup seal should be stocked to reduce repair time.
  • Page 7 Recommended Barrier Supply System for Dual Pressurized Seals Figure 8 pressure source, Plan 53A normally open outlet pressure orifice transmitter seal end view reservoir liquid fill, inlet normally closed level level indicator transmitter cooling coils cooling in cooling out drain, normally closed Plan 54...
  • Page 8 Flowserve Corporation has established industry leadership in the design and manufacture of its products. Telephone: 31 765 028 200 When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products Telefax: 31 765 028 487 might be used in numerous applications under a wide variety of industrial service conditions.

This manual is also suitable for: