Download Print this page
Flowserve BPO Installation Instructions Manual
Flowserve BPO Installation Instructions Manual

Flowserve BPO Installation Instructions Manual

Single inside pusher type seals

Advertisement

Quick Links

Single Inside Pusher Type Seals
BPO, BPT, BRO, BRT, PTO, PT, RO, RO-TT,
and others
1
Equipment Check
1.1
Follow plant safety regulations prior to equipment disassembly:
1.1.1
Wear designated personal safety equipment
1.1.2
Isolate equipment and relieve any pressure in the system
1.1.3
Lock out equipment driver and valves
1.1.4
Consult plant Safety Data Sheet (SDS) files for hazardous material regulations
1.2
Disassemble equipment in accordance with the equipment manufacturer's instructions
to allow access to seal installation area.
1.3
Remove existing sealing arrangement (mechanical seal or otherwise).
Clean seal chamber and shaft thoroughly.
1.4
Inspect surfaces under gaskets to ensure they are free from pits or scratches. Break all sharp
corners on shaft steps, threads, reliefs, shoulders, key ways, etc. over which gasket(s) must
pass and/or seal against.
1.5
Check shaft or sleeve OD, seal chamber bore, seal chamber depth, gland pilot, stud diameter,
stud bolt pattern and distance to first obstruction to ensure they are dimensionally the same
as shown in the seal assembly drawing.
1.6
Check seal assembly drawings for any modifications (reworks) to be made to the equipment
for mechanical seal installation and act accordingly.
1.7
The equipment must be earthed to prevent sparks due to static electricity discharge.
Experience In Motion
Installation
Instructions

Advertisement

loading

Summary of Contents for Flowserve BPO

  • Page 1 Installation Instructions Single Inside Pusher Type Seals BPO, BPT, BRO, BRT, PTO, PT, RO, RO-TT, and others Equipment Check Follow plant safety regulations prior to equipment disassembly: 1.1.1 Wear designated personal safety equipment 1.1.2 Isolate equipment and relieve any pressure in the system 1.1.3...
  • Page 2 0.10 - 0.15 mm (0.004 - 0.006 inch). If equipment is found outside the general range, contact the equipment manufacturer and your Flowserve representative to verify the equipment’s suitability for the seal. Seal chamber squareness to the shaft centerline should be within 0.0005 mm/mm (0.0005 inch/inch) of seal...
  • Page 3 Single Inside Pusher Type Seal Installation Single End Suction Vertical Split Case Pumps (1 box) Scribe mark A on the shaft or sleeve to line up with the face of the seal housing. Scribe mark B at the seal setting point shown enclosed in a rectangular box on the assembly drawing included with the seal.
  • Page 4 Double Suction and Multistage Horizontal Split Case Pumps (2 boxes) Scribe mark A on the shaft or sleeve to line up with the face of the seal housing. Scribe mark B at the seal setting point shown enclosed in a rectangular box on the assembly drawing included with the seal.
  • Page 5 Vertical In-line Pumps For back pullout designs and shaft designs not incorporating a rigid spacer coupling use procedure as for single end suction vertical split case pumps. For shaft designs incorporating a rigid spacer coupling: Scribe mark A on the shaft or sleeve to line up with the face of the seal housing. Some pump designs incorporate a shaft or sleeve with vertical or horizontal pins for setting and driving the seal.
  • Page 6: Operational Recommendations

    Do not allow the equipment to run for any extended time if the seal gets hot or squeals. For special problems encountered during installation, contact your nearest Flowserve Sales and Service Representative or Authorized Distributor.
  • Page 7 This product is a precision sealing device. The design and dimension tolerances are critical to seal performance. Only parts supplied by Flowserve should be used to repair a seal. To order replacement parts, refer to the part code and B/M number. A spare backup seal should be stocked to reduce repair time.
  • Page 8 Flowserve Corporation has established industry leadership in the design and manufacture of its products. Telephone: 31 765 028 200 When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products Telefax: 31 765 028 487 might be used in numerous applications under a wide variety of industrial service conditions.

This manual is also suitable for:

BptBroBrtPtoPtRo ... Show all