Connection system

Advertisement

6
RayClic-PC, RayClic-PS, RayClic-PT Installation Instructions
End Seal Installation
1
1"
• Score around and down the outer
jacket 1-inch from the end.
• Remove the outer jacket.
• Do not cut or damage the inner jacket.
2A
• Using wire cutters, cut away aluminum wrap
close to braid and outer jacket.
IceStop and XL-Trace
HWAT
HWAT
HWAT
2
• Remove exposed braid.
3
• Push end seal completely onto heating cable.
H
W
A
T
Note: The end seal is designed to be
installed only once; it cannot be removed from the
heating cable once installed. Do not use until ready
for final installation.
IceStop and XL-Trace
IceStop and XL-Trace
H
W
A
T