ABB M22301 User Manual

ABB M22301 User Manual

4.3" video handset indoor station
Hide thumbs Also See for M22301:

Advertisement

VER:1.1 │
│ 20.10.2015
ABB-Welcome
Pos : 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.doc x @ 111084 @ @ 1
M22301-.
M22302-.
M22303-.
4.3" Video handset
indoor station
=== Ende der Liste fü r T extmar ke Cover ===

Advertisement

Table of Contents
loading

Summary of Contents for ABB M22301

  • Page 1 VER:1.1 │ │ 20.10.2015 ABB-Welcome Pos : 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.doc x @ 111084 @ @ 1 M22301-. M22302-. M22303-. 4.3" Video handset indoor station...
  • Page 2: Table Of Contents

    Pos : 4 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Inhal ts verz eic hnis (--> Fü r alle D okumente <--)/Inhalts verz eichnis @ 19\mod_1320649044386_15.doc x @ 109653 @ @ 1 Safety ......................3 Intended use ....................3 Environment ....................3 ABB devices ................. 3 Operations ..................... 5 Standard operations ..............5 4.1.1 Control elements ................
  • Page 3: Safety

    ABB devices Pos : 13 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Fü r alle D okumente <--)/Hinweis e/Hi nweis - U mwelt - ABB El ektr ogeräte @ 19\mod_1323162745839_15.doc x @ 110867 @ @ 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal.
  • Page 4 ABB-Welcome ABB products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS) (EU-REACH ordinance and law for the implementation of the ordinance (EG) No.1907/2006) — 4 —...
  • Page 5: Operations

    ABB-Welcome Pos : 18 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Bedi enung @ 18\mod_1302613924165_15.doc x @ 103365 @ 1 @ 1 Operations Pos : 19 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Nor maler Betrieb @ 18\mod_1302768820965_15.doc x @ 103540 @ 2 @ 1 Standard operations Pos : 20 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Bedi enel emente @ 20\mod_1323260220559_15.doc x @ 111647 @ 3 @ 1...
  • Page 6 1B In standby mode, pick up handset to enter the communication menu. 4.3" display 2A M22301-. , with B/W display. 2B M22302-. / M22303-., with color display. Unlock button 3A Open the door by pressing this button at any time.
  • Page 7 ABB-Welcome (default function). 6B In standby mode, long-press this button for 3 seconds to send SOS alarm to guard unit. If LED flashes slowly, SOS was successfully sent to guard unit. If LED flashes fast, SOS was not successful. 6C *Programmable for additional function, e.g. call guard unit, intercom , etc.
  • Page 8: Control Actions

    ABB-Welcome Pos : 26 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Bedi enaktionen @ 20\mod_1323262294281_15.doc x @ 111911 @ 2 @ 1 Control actions Pos : 27 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Sprec h- und Videover bindung @ 20\mod_1323262368700_15.doc x @ 111927 @ 3 @ 1 4.2.1...
  • Page 9 ABB-Welcome Hold this button to enter the brightness setttings. The rest time of the conversation. Number of outdoor stations Pos : 29 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1...
  • Page 10: Display And Volume Settings During A Call

    ABB-Welcome Pos : 30 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Tuer oeffnen @ 20\mod_1323263277453_15.doc x @ 111935 @ 3 @ 1 4.2.2 Display and volume settings during a call Pos : 31 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/T uer oeffnen - 83220- AP- xxx @ 20\mod_1323267958479_15.doc x @ 112109 @ @ 1...
  • Page 11: Communication Menu

    ABB-Welcome Pos : 33 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Stumm s chalten @ 20\mod_1323263607142_15.doc x @ 111951 @ 3 @ 1 Pos : 66 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1 4.2.3...
  • Page 12 ABB-Welcome 4.2.3.3 Call guard unit CALL GUARD UNIT Call Guard Unit Fig. 5: Call guard unit 4.2.3.4 Broadcast BROADCAST Long-pressing “√“ button to broadcast Fig. 6: Broadcast This funtion is available in M22302-. / M22303-., color video handset indoor station.
  • Page 13 ABB-Welcome 4.2.3.5 Switch actuator SWITCH ACTUATOR Actuator 1 (001) Fig. 7: Switch actuator First, set the actuator list in the “system settings-switch actuator” menu. After choosing a list, press button √ to enable the lock or light that is connected to the switch actuator.
  • Page 14: Settings

    ABB-Welcome Settings 4.3.1 Overview Press button to enter the system settings menu. The following functions are available: Functions Intercom settings -Set intercom lists among different apartments or within the same apartment Switch actuator -Set the actuator list in this menu...
  • Page 15: Intercom Call Settings

    ABB-Welcome 4.3.2 Intercom call settings Intercom 1 (001) Intercom 2 Add New Fig. 8: Intercom setting menu Functions Choose the previous selection or scroll up Choose the next selection or scroll down Confirm the selection or enter to edit it Return to the previous screen Add a new intercom list.
  • Page 16 ABB-Welcome Add a new list INTERCOM External Intercom Call Type Target Address Rename mike Save Cancel Fig. 9: Add new intercom Functions Enter to choose the call type: -an external intercom means a call from different apartments. -an internal intercom means a call from within the same apartment.
  • Page 17: Switch Actuator Settings

    ABB-Welcome 4.3.3 Switch actuator settings SWITCH ACTUATOR Actuator 1 (001) Add New Add a new list SWITCH ACTUATOR Target Address Rename light Save Cancel Fig. 10: Switch actuator settings Functions Existing switch actuator list: Press button √ to modify the settings.
  • Page 18: Program Button Settings

    ABB-Welcome 4.3.4 Program button settings PROGRAM BUTTON Button 1 Release 2nd-Lock Button 2 None Fig. 11: Program button settings Functions Set functions for the program button, e.g. releasing second lock, calling guard unit, intercom call, enabling the switch actuator. *second lock means the lock is connected with an outdoor station. (NC-NO-...
  • Page 19: Call Forward Settings

    ABB-Welcome 4.3.5 Call forward settings CALL FORWARD √ Call Forward Call Type Indoor Target Address Save Cancel Fig. 12: Call forward settings Functions Enable/disable the call forward function. Enter to choose a call type, including indoor or guard unit. Enter to change the target address if the call type is an indoor station.
  • Page 20: Auto Unlock Settings

    ABB-Welcome 4.3.6 Auto unlock settings AUTO UNLOCK √ Auto Unlock √ Time 1 Time 2 : : : : Fig. 13: Auto unlock settings Functions Enable/disable the auto unlock function. Enable/disable the auto unlock during Time 1. Set starting time and ending time for Time 1 Enable/disable auto unlock during Time 2.
  • Page 21: Outdoor Station Password Settings

    ABB-Welcome 4.3.7 Outdoor station password settings SET OS PASSWORD √ Enable Password 12345678 Enter Password (3-8 digits) Fig. 14: Outdoor station password settings Functions Enable/disable the password functions Enter a 3-8 digit password.. *Only available with the keypad. *This function only can be set in the master indoor station.
  • Page 22: Ringtone Settings

    ABB-Welcome 4.3.8 Ringtone settings RING TONE Ring Tone 1 Default Outdoor Ring Tone 2 Other Outdoors Ring Tone 3 Doorbell Ring Tone 4 Others Fig. 15: Ringtone Functions Select the bell sound for the default outdoor station. Select the bell sound for other outdoor stations.
  • Page 23: Volume Settings

    ABB-Welcome 4.3.9 Volume settings VOLUME Volume 3 Ringtone Volume √ Touchbutton Tone √ Repeated Tone Fig. 16: Volume settings Functions Set the volume of bell sound. Enable/disable the feedback tone that sounds when the touch button is pressed. The ringtone can be set as fixed or cycled.
  • Page 24: Date And Time Settings

    ABB-Welcome 4.3.10 Date and time settings DATE AND TIME 2013 Date(YYYY-MM-DD) : Time Summer Time √ Fig. 17: Date and time settings Functions Set the date. Set the time. Enable/disable the summertime function. *This funtion is available in M22302-. / M22303-., color video handset indoor station.
  • Page 25: Other Settings

    ABB-Welcome 4.3.11 Other settings OTHER SETTINGS Auto Full Screen √ √ Door Status Check √ Auto-snapshots √ Missed Call Fig. 18: Other settings Functions Enable/disable the auto full screen function. Enable/disable the door status check function. (Only available if the sensor is installed with an outdoor station;...
  • Page 26: Blacklist Settings

    ABB-Welcome 4.3.12 Blacklist settings BLACKLIST Blacklist 1 (001) Add New BLACKLIST Target Address Save Cancel Fig. 19: Blacklist settings Functions The existed blacklist. Press √ button to modify the setting. Add a new blacklist. A total of 32 blacklists can be added.
  • Page 27: History Review

    ABB-Welcome 4.3.13 History review HISTORY 1/63 2013-03-21 Outdoor - 1 ● 16:45 ● 2013-03-21 Outdoor - 1 16:45 ● 2013-03-21 Outdoor - 1 14:24 Outdoor -1 Fig. 20: History review Functions Up to 100 events can be recorded in the history menu.
  • Page 28 ABB-Welcome Press this button to view details of this event. Two photos are always made when a visitor rings the bell. Press this button to delete a recorded item *This funtion is available in M22302-. / M22303-., color video handset indoor station.
  • Page 29: Camera List

    ABB-Welcome 4.3.14 Camera List CAMERA LIST The list is disabled Outdoor1-1 Outdoor 1-2 Camera1 CAMERA LIST- Camera 1 Enable √ Front door Rename √ Visible doorbell Save Cancel — 29 —...
  • Page 30 ABB-Welcome Functions Display the status of camera list. Only when the list is enable, user can make a surveilliance according to this camera list, and user can also modify this camera list. Display the cameras from camera interface. Press this button to enable or disable camera list.
  • Page 31: Language Settings

    ABB-Welcome 4.3.15 Language settings LANGUAGE English Franç aise Italiano Español Português Fig. 21: Language settings 4.3.16 Information INFORMATION Flash Version: V2.07_150629 MCU Version: V2.07_150703 M/S: Master Indoor St. Add.: Default Outdoor: Fig. 22: Information Information for outdoor station. (Scan QR code to get detailed instructions for the indoor station.)
  • Page 32: Reset Factory Default

    ABB-Welcome 4.3.17 Reset factory default RESET FACTORY DEFAULT Are you sure to reset? Reset All Settings √ Clear All Data × Cancel Fig. 23: Reset factory default Functions Reset all settings: Reset the device and restore all default configurations. The operation does not delete the programmed data and history, such as intercom lists and switch actuator lists.
  • Page 33: Cleaning

    ABB-Welcome Pos : 67 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Rei nigung @ 19\mod_1310733980533_15.doc x @ 107853 @ 2 @ 1 Cleaning Pos : 68 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Rei nigung/Rei nigung Touc hscreenmonitor @ 19\mod_1310734108978_15.doc x @ 107862 @ @ 1 Caution Risk of damage to the screen surface.
  • Page 34: Adjusting The Device

    ABB-Welcome Pos : 70 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Geraeteei nstellungen @ 18\mod_1302768847744_15.doc x @ 103548 @ 2 @ 1 Adjusting the device Pos : 71 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Absc hlus s widerstand @ 19\mod_1321958079906_15.doc x @ 110083 @ 3 @ 1 Pos : 72 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Absc hl uss widerstand setzen 83220-AP- xxx @ 19\mod_1310723392369_15.doc x @ 107841 @ @ 1...
  • Page 35: Technical Data

    ABB-Welcome Pos : 76 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Tec hnisc he D aten @ 18\mod_1302615863001_15.doc x @ 103416 @ 1 @ 1 Technical data Pos : 77 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/T ec hnische D aten - 83220-AP- xxx @ 18\mod_1303212854559_15.doc x @ 103705 @ @ 1...
  • Page 36: Mounting/Installation

    ABB-Welcome Pos : 79 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Fü r alle D okumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.doc x @ 103373 @ 1 @ 1 Mounting/Installation Pos : 80 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 18 \mod_1302617821491_15.doc x @ 103465 @ @ 1...
  • Page 37: General Installation Instructions

    ABB-Welcome General installation instructions • Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station, system device). • Do not install the system controller directly next to the bell transformer and other power supplies (to avoid interference).
  • Page 38: Mounting

    ABB-Welcome Pos : 84 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Fü r alle D okumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.doc x @ 103424 @ 2 @ 1 Mounting Pos : 85.1 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/DoorEntr y/83220-AP- xxx/M ontag e - M odul e/Montage - Montagedose -- 83220-AP- xxx @ 19\mod_1323250406848_15.doc x @ 111098 @ @ 1 Recommended installation height 1.5 meters (4.9 feet)
  • Page 39 ABB-Welcome The bottom of the device has screw holes for fastening on the wall according to the illustrations above. In addition, the bottom of the device can be affixed to the existing flush-mounted box. The dimensions of the compatible flush-mounted box is shown in illustrations above.
  • Page 40 ABB-Welcome Mounted on the wall Affix the bottom of the device to the wall. Latch the upper part of the device onto its bottom part. Place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp.
  • Page 41 ABB-Welcome Mounted with desktop bracket Affix the bottom of the device to the desktop bracket. Latch the upper part of the device onto its bottom part. Place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until it is caught by the clamp.
  • Page 42 We reserve the right to, at any time, make technical changes or changes in the content of this document without prior notice. The detailed specifications agreed to at the time of ordering appl ies to all orders. ABB accepts no responsibility for possible errors or omissions in this document.

This manual is also suitable for:

M22303M22302

Table of Contents