Mixed-Signal Oscilloscope
MSO-2000E & MSO-2000EA
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER
800.561.8187
information@itm.com
www.
.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MSO-2000E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GW Instek MSO-2000E

  • Page 1 Mixed-Signal Oscilloscope MSO-2000E & MSO-2000EA USER MANUAL ISO-9001 CERTIFIED MANUFACTURER 800.561.8187 information@itm.com www. .com...
  • Page 2 September 2016 This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Good Will company. The information in this manual was correct at the time of printing. However, Good Will continues to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any time without notice.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Table of Contents SAFETY INSTRUCTIONS ..........7 GETTING STARTED ............12 MSO-2000E/2000EA Series Overview ... 14 Appearance .......... 18 Set Up ..........31 Built-in Help ........41 MEASUREMENT ............42 Basic Measurement ......43 Automatic Measurement ...... 50 Cursor Measurement ......
  • Page 4 MSO-2000E & 2000EA User Manual APPLICATIONS ............. 258 Introduction ........259 Go-NoGo application ......261 DVM application ........ 266 Data Log application ......268 Digital Filter application ....270 Mask application........ 272 SAVE/RECALL ............... 282 File Format/Utility ......283 Create/Edit Labels ......289 Save ...........
  • Page 5 TABLE OF CONTENTS Dimensions ........349 Declaration of Conformity ....350 INDEX ................351 800.561.8187 information@itm.com www. .com...
  • Page 6 800.561.8187 information@itm.com www. .com...
  • Page 7: Safety Instructions

    SAFETY INSTRUCTIONS AFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow during operation and storage. Read the following before any operation to insure your safety and to keep the instrument in the best possible condition. Safety Symbols These safety symbols may appear in this manual or on the Product name.
  • Page 8 MSO-2000E & 2000EA User Manual Do not dispose electronic equipment as unsorted municipal waste. Please use a separate collection facility or contact the supplier from which this instrument was purchased. Safety Guidelines Make sure the BNC input voltage does not General ...
  • Page 9  (Pollution Degree) EN 61010-1:2010 specifies the pollution degrees Note and their requirements as follows. The MSO-2000E/2000EA falls under degree 2. Pollution refers to “addition of foreign matter, solid, liquid, or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface resistivity”.
  • Page 10 MSO-2000E & 2000EA User Manual Location: Indoor Storage  environment Temperature: -10°C to 60°C  Humidity: Up to 93% RH (non-condensing) /  ≤40ºC, up to 65% RH (non-condensing) / 41ºC ~ 60 ºC Do not dispose this instrument as unsorted Disposal municipal waste.
  • Page 11 SAFETY INSTRUCTIONS Power cord for the United Kingdom When using the oscilloscope in the United Kingdom, make sure the power cord meets the following safety instructions. NOTE: This lead/appliance must only be wired by competent persons WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in this lead are coloured in accordance with the following code: Green/ Yellow:...
  • Page 12 Integrated instruments and series lineup ......14 Main Features ................. 15 Accessories................16 Appearance ..............18 MSO-2000E/2000EA 4-channel models Front Panel ... 18 MSO-2000E/2000EA 2-channel models Front Panel ... 19 MSO-2000E Rear Panel ............26 MSO-2000EA Rear Panel ............ 26 Display ..................
  • Page 13: Getting Started

    GETTING STARTED Built-in Help ..............41 800.561.8187 information@itm.com www. .com...
  • Page 14: Mso-2000E/2000Ea Series Overview

    ✓ ✗ MSO-2000EA ✓ ✓ The MSO-2000E/2000EA series consists of 6 models, divided into 2- channel and 4-channel versions. Note that throughout the user manual, the term “MSO-2000E/2000EA” refers to all models of the series, unless stated otherwise. Model name...
  • Page 15: Main Features

    GETTING STARTED Main Features 8 inch, 800 x 480, WVGA TFT display. Features  Available from 70MHz to 200MHz.  Real-time sampling rate of 1GSa/s (2 channel  models), 1GSa/s max. (4 channel models). Deep memory: 10M points record length. ...
  • Page 16: Accessories

    MSO-2000E & 2000EA User Manual USB host port: front panel, for storage devices. Interface  USB device port: rear panel, for remote control  or printing. Ethernet port as standard.  Probe compensation output with selectable  output frequency (1kHz ~ 200kHz).
  • Page 17 GETTING STARTED Creates shape templates for signal Mask comparison. Allows the scope to mount a network Remote Disk share drive. Optional Part number Description Accessories Demonstration mode that is used Demo mode with the GDB-03 demo board. Demo board. GDB-03 Drivers, others USB driver LabVIEW driver...
  • Page 18: Appearance

    MSO-2000E & 2000EA User Manual Appearance MSO-2000E/2000EA 4-channel models Front Panel Function Variable knob Autoset, Run/Stop, Single keys Hardcopy key and Select key and Default settings Horizontal controls Side menu keys Trigger Menu key controls Bottom Option key menu Vertical...
  • Page 19: Mso-2000E/2000Ea 2-Channel Models Front Panel

    GETTING STARTED MSO-2000E/2000EA 2-channel models Front Panel Function Variable knob Autoset, Run/Stop, Single keys Hardcopy key and Select key and Default settings Horizontal controls Side menu keys Trigger Bottom Menu key controls menu Option key keys Vertical controls Power button...
  • Page 20 MSO-2000E & 2000EA User Manual The side menu and bottom menu keys are used to Menu Keys make selections from the soft-menus on the LCD user interface. To choose menu items, use the 7 Bottom menu keys located on the bottom of the display panel.
  • Page 21 GETTING STARTED The Function keys are used to enter and configure Function Keys different functions on the MSO-2000E/2000EA. Configures and runs automatic Measure Measure measurements. Configures and runs cursor Cursor Cursor measurements. Configures and runs GW Instek applications. Configures the acquisition mode,...
  • Page 22 MSO-2000E & 2000EA User Manual Press to Freeze (Stop) or continue Run/Stop Key Run/Stop (Run) signal acquisition (page 46). The run stop key is also used to run or stop Segmented Memory acquisition (page 95). Sets the acquisition mode to single...
  • Page 23 GETTING STARTED The Play/Pause key allows you to Play/Pause view each search event in succession – to effectively “play” through each search event. It is also used to play through a waveform/trace in zoom mode. The Search key accesses the search Search Search function menu to set the search...
  • Page 24 MSO-2000E & 2000EA User Manual Sets the vertical position of the Vertical POSITION waveform/trace. Push the knob to POSITION reset the vertical position to zero. PUSH TO ZERO Press the CH1~4 key to set and Channel Menu configure the corresponding channel.
  • Page 25 GETTING STARTED Accepts input signals. Channel Inputs Input impedance: 1MΩ. Capacitance: 16pF CAT I Type A, 1.1/2.0 compatible. Used USB Host Port for data transfer. Accepts the DUT ground lead for Ground Terminal common ground. The probe compensation output is Probe used for probe compensation.
  • Page 26: Mso-2000E Rear Panel

    MSO-2000E & 2000EA User Manual MSO-2000E Rear Panel USB Device port LAN port Calibration output Go/No Go output Ser. No. Label LINE VOLTAGE AC 100 240V RANGE CAUTION FREQUENCY 60Hz TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND.
  • Page 27 GETTING STARTED The USB Device port is used for USB Device Port remote control. The LAN port is used for remote LAN (Ethernet) control over a network or when Port combined with the Remote Disk app, allows the scope to be mounted to a share disk.
  • Page 28: Display

    MSO-2000E & 2000EA User Manual Display Below is a general description of the main display. As the display changes while activating the different functions of the MSO- 2000E/2000EA, please refer to each function sub-chapters of this user manual for more details.
  • Page 29 GETTING STARTED Bus indicator(B) Reference waveform indicator Math indicator Shows the position of the trigger. Trigger Position Horizontal Status Shows the horizontal scale and position. Date and Time Current date and time (page 204). Shows the trigger level on the graticule. Trigger Level Memory Bar The ratio and the position of the displayed...
  • Page 30 MSO-2000E & 2000EA User Manual Trigger source, slope, Trigger voltage and coupling. Configuration Horizontal scale, Horizontal Status horizontal position. For trigger details, see page 151. Channel 1, DC coupling, Channel Status 2V/Div. For channel details, see page 116. 800.561.8187 information@itm.com www.
  • Page 31: Set Up

    GETTING STARTED Set Up Tilt Stand To tilt, pull the legs forward, as shown below. Tilt To stand the scope upright, push the legs back Stand under the casing as shown below. 800.561.8187 information@itm.com www. .com...
  • Page 32: Power Up

    MSO-2000E & 2000EA User Manual Power Up The MSO-2000E/2000EA accepts line voltages of Requirements 100 ~ 240V at 50 or 60Hz. 1. Connect the power cord to Step the rear panel socket. 2. Press the POWER key. The POWER display becomes active in ~ 30 seconds.
  • Page 33: First Time Use

    This section describes how to connect, adjust the Background scale and compensate the probe. Before operating the MSO-2000E/2000EA in a new environment, run these steps to make sure the instrument performs at its full potential. Follow the procedures on the previous page.
  • Page 34 MSO-2000E & 2000EA User Manual VARIABLE HORIZONTAL SCALE POSITION PUSH TO ZERO VERTICAL TRIGGER POSITION POSITION LEVEL POSITION POSITION MATH PUSH TO PUSH TO PUSH TO PUSH TO PUSH TO ZERO ZERO ZERO ZERO ZERO SCALE SCALE SCALE SCALE POWER 16pF 300Vrms MAX.
  • Page 35 GETTING STARTED Under Over Normal Compensation Compensation 9. Start operations Continue with the other operations. Measurement: page 42 Configuration: page 83 Using the Logic Using the Arbitrary Analyzer: page 207. Wave Generator (MSO- 2000EA only): page 223. Applications: page 258 Save/Recall: page 282 File Utilities: page 308 Hardcopy key: page 315...
  • Page 36: How To Use This Manual

    MSO-2000E & 2000EA User Manual How to Use This Manual This section describes the conventions used in this Background manual to operate the MSO-2000E/2000EA. Throughout the manual any reference to pressing a menu key refers to the keys directly below or beside any menu icons or parameters.
  • Page 37 GETTING STARTED Example 1 1. Press a bottom menu key to access the side menu. 2. Press a side menu key to either set a parameter or to access a sub menu. 3. If accessing a sub menu or setting VARIABLE a variable parameter, use the Variable knob to scroll through...
  • Page 38 MSO-2000E & 2000EA User Manual 5. Press the desired menu key to select it. The circular arrow will become highlighted. 6. Use the Variable knob to edit the value. Toggling a Menu Parameter 7. Press the bottom menu key to toggle the parameter.
  • Page 39 GETTING STARTED 8. To reduce the side menu, press the corresponding bottom menu that brought up the side menu. For example: Press the Source soft-key to reduce the Source menu. Reduce Lower Menu VARIABLE Measure Cursor Test Acquire Autoset Display Help Save/Recall Utility...
  • Page 40 MSO-2000E & 2000EA User Manual VARIABLE Measure Cursor Test Acquire Autoset Display Help Save/Recall Utility Run/Stop HORIZONTAL Single SCALE 10. Press the Menu Off key to POSITION Select Search Zoom Default Set/Clear PUSH TO reduce the side menu, press ZERO...
  • Page 41: Built-In Help

    GETTING STARTED Built-in Help The Help key accesses a context sensitive help menu. The help menu contains information on how to use the front panel keys. Panel Operation 1. Press the Help key. The Help display changes to Help mode. 2.
  • Page 42: Measurement

    MSO-2000E & 2000EA User Manual EASUREMENT Basic Measurement......43 Channel Activation ..............43 Autoset ..................44 Run/Stop ................46 Horizontal Position/Scale ............ 47 Vertical Position/Scale ............49 Automatic Measurement ...... 50 Measurement Items ............... 50 Add Measurement ..............54 Remove Measurement ............57 Gated mode ................
  • Page 43: Basic Measurement

    MEASUREMENT Basic Measurement This section describes the basic operations required in capturing, viewing and measuring the input signal. For more detailed or more specific operations, see the following chapters. Advanced Configuration → from page 83  Logic Analyzer→ from page 207 ...
  • Page 44: Autoset

    MSO-2000E & 2000EA User Manual To de-activate a channel, press De-activate the corresponding channel key Channel again. If the channel menu is not open, press the channel key twice (the first press shows the Channel menu). To activate the default state,...
  • Page 45 MEASUREMENT Before After 3. To undo Autoset, press Undo Autoset from the bottom menu. 4. Choose between Fit Screen Mode Change modes and AC Priority Mode from the bottom menu. 5. Press the Autoset key again to use Autoset Autoset in the new mode. Fit Screen Mode AC Priority Autoset does not work in the following situations:...
  • Page 46: Run/Stop

    MSO-2000E & 2000EA User Manual Run/Stop By default, the waveform on the display is Background constantly updated (Run mode). Freezing the waveform by stopping signal acquisition (Stop mode) allows flexible observation and analysis. To enter Stop mode, two methods are available: pressing the Run/Stop key or using the Single Trigger mode.
  • Page 47: Horizontal Position/Scale

    MEASUREMENT Horizontal Position/Scale For more detailed configuration, see page 108. The horizontal position knob Set Horizontal POSITION Position moves the waveform left and right. PUSH TO ZERO Pressing the horizontal position Set Horizontal POSITION knob will reset the horizontal Position to 0 position to 0.
  • Page 48 MSO-2000E & 2000EA User Manual Range 1ns/div ~ 100s/div, 1-2-5 increments The scale is displayed to the left of the H icon at the bottom of the screen. The display bar indicates how much Display bar of the waveform is displayed on the screen at any given time.
  • Page 49: Vertical Position/Scale

    MEASUREMENT Vertical Position/Scale For more detailed configuration, see page 116. To move the waveform up or down, turn Set Vertical POSITION the vertical position knob for each channel. Position PUSH TO ZERO Push the vertical position knob to POSITION reset the position to 0. As the waveform moves, the vertical position of the cursor PUSH TO...
  • Page 50: Automatic Measurement

    MSO-2000E & 2000EA User Manual Automatic Measurement The automatic measurement function measures and updates major items for Voltage/Current, Time, and Delay type measurements. Measurement Items V/I Measurements Time Meas. Delay Meas. Overview Frequency Pk-Pk Period RiseTime Amplitude FallTime High +Width...
  • Page 51 MEASUREMENT Difference between the Amplitude global high value and the global low value, measured over the entire waveform or gated region. (=high − low) Global high voltage. See High page 59 for details. Global low voltage. See page 59 for details. The arithmetic mean value is Mean calculated for all data...
  • Page 52 MSO-2000E & 2000EA User Manual Rise overshoot ROVShoot Fall overshoot FOVShoot Rise preshoot RPREShoot Fall preshoot FPREShoot Frequency of the waveform. Time Frequency Measurement Waveform cycle time. Period (=1/Freq) The time required for the RiseTime leading edge of the first...
  • Page 53 MEASUREMENT Ratio of signal pulse Duty Cycle compared with whole cycle. =100x (Pulse Width/Cycle) Measures the number of +Pulses positive pulses. Measures the number of -Pulses negative pulses. Measures the number of +Edges positive edges. Measures the number of -Edges negative edges.
  • Page 54: Add Measurement

    MSO-2000E & 2000EA User Manual Time between: Source 1 first rising edge and Source 2 last falling edge. Time between: Source 1 first falling edge and Source 2 last rising edge. Time between: Source 1 first falling edge and Source 2 last falling edge.
  • Page 55 MEASUREMENT 3. Choose either a V/I, Time or Delay measurement from the side menu and choose the type of measurement you wish to add. Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, (Voltage/ Current) Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot Frequency, Period, RiseTime,...
  • Page 56 MSO-2000E & 2000EA User Manual 5. To set the source, press either the Source1 or Source2 key from the side menu and choose the source. Source1: CH1~CH4, Math, D0~D15 Range Source2: CH1~CH4, Math Source 2 is only applicable to Delay (Note) measurements.
  • Page 57: Remove Measurement

    MEASUREMENT Remove Measurement Individual measurements can be removed at any time using the Remove Measurement function. 1. Press the Measure key. Remove Measure Measurement Item 2. Press Remove Measurement from the bottom menu. 3. Press Select Measurement and select the item that you want to remove from the measurement list.
  • Page 58: Display All Mode

    MSO-2000E & 2000EA User Manual 3. Choose one of the gating modes from the side menu: Off (full record), Screen, Between Cursors. If Between Cursors is selected, the Page 65 Cursors On cursor positions can be edited by Screen using the cursor menu.
  • Page 59: High Low Function

    MEASUREMENT To remove the measurement results, Remove Measurements press OFF. Delay type measurements are not available in this Delay mode as only one channel is used as the source. Measurements Use the individual measurement mode (page 54) instead. Only Frequency, Period, +Width, -Width and Duty Digital channels Cycle measurements are supported for the digital channels D0~D15.
  • Page 60 MSO-2000E & 2000EA User Manual Uses histograms to determine the Histogram high-low values. This mode ignores any pre-shoot or overshoot values. This mode is particularly useful for pulse-type waveforms high Sets the high-low values as the Min-max minimum or maximum measured values.
  • Page 61: Statistics

    MEASUREMENT To return to the default High-Low Restore Default High-Low settings, press Set to Defaults. Settings Statistics The Statistics function can be used to view a Background number of statistics for the selected automatic measurements. The following information is displayed with the Statistics function: Currently measured value Value The mean value is calculated from...
  • Page 62 MSO-2000E & 2000EA User Manual The variance of the currently Standard Deviation measured value from the mean. The standard deviation equals the squared root of the variance value. Measuring the standard deviation can, for example, determine the severity of jitter in a signal.
  • Page 63: Reference Levels

    MEASUREMENT To reset the standard deviation Reset Statistics calculations, press Reset Statistics. Reference Levels The reference level settings determine the Background measurement threshold levels for some measurements like the Rise Time measurement. High Ref: Sets the high reference level. Mid Ref: Sets the middle reference for the first and second waveforms.
  • Page 64 MSO-2000E & 2000EA User Manual 0.0% ~ 100% High Ref 0.0% ~ 100% Mid Ref 0.0% ~ 100% 0.0% ~ 100% Low Ref 4. Press Set to Defaults to set the Default Settings reference levels back to the default settings.
  • Page 65: Cursor Measurement

    MEASUREMENT Cursor Measurement Horizontal or vertical cursors are used to show the position and values of waveform measurements and math operation results. These results cover voltage, time, frequency and other math operations. When the cursors (horizontal, vertical or both) are activated, they will be shown on the main display unless turned off.
  • Page 66 MSO-2000E & 2000EA User Manual 4. The cursor position information appears on the top left hand side of the screen Hor. position, Voltage/Current Cursor Hor. position, Voltage/Current Cursor Delta (difference between cursors) dV/dt or dI/dt 5. Use the Variable knob to move the VARIABLE movable cursor(s) left or right.
  • Page 67 MEASUREMENT Example Horizontal cursors FFT cursors can use different units. For FFT details, see page Hor. position, dB/Voltage Cursor Hor. Position, dB/Voltage Cursor Delta (difference between cursors) dV/dt or d/dt Example Horizontal cursors XY mode cursors measure a number of X by Y XY Mode measurements.
  • Page 68 MSO-2000E & 2000EA User Manual Time, rectangular, polar co- Cursor ordinates, product, ratio. Time, rectangular, polar co- Cursor ordinates, product, ratio. Delta (difference between cursors) Example Horizontal cursors 800.561.8187 information@itm.com www. .com...
  • Page 69: Use Vertical Cursors

    MEASUREMENT Use Vertical Cursors 1. Press the Cursor key twice. Panel Operation/ Cursor Range 2. Press V Cursor from the bottom menu if it is not already selected. 3. When the V Cursor is selected, repeatedly pressing the V Cursor key or the Select key will toggle which vertical cursor is selected.
  • Page 70 MSO-2000E & 2000EA User Manual 6. To change the units of the vertical Select Units position, press V Unit. Base (source wave units), % (ratio) Units 7. To set the 0% and 100% ratio Base or Ratio references for the current cursor...
  • Page 71 MEASUREMENT Example Horizontal Vertical cursors cursors XY mode cursors measure a number of X by Y XY Mode measurements. See page 87. Rectangular, polar co-ordinates, Cursor product, ratio. Rectangular, polar co-ordinates, Cursor product, ratio. Delta (difference between cursors) 800.561.8187 information@itm.com www.
  • Page 72 MSO-2000E & 2000EA User Manual Example Horizontal cursors Vertical cursors 800.561.8187 information@itm.com www. .com...
  • Page 73: Math Operation

    MEASUREMENT Math Operation Basic Math Overview & Operators The Math function performs basic math functions Background (addition, subtraction, multiplication, division) on the input signals or the reference waveforms. The resultant waveform will be shown on the screen in real-time. Adds the amplitude of two signals. Addition (+) CH1~4, Ref1~4 Source...
  • Page 74 MSO-2000E & 2000EA User Manual 4. Press Operator to choose the math operation. +, -, ×, ÷ Range 5. Select Source 2 from the side menu. CH1~4, Ref1~4 Range 6. The math measurement result appears on the display. The vertical scale of the math waveform appears at the bottom of the screen.
  • Page 75: Fft Overview & Window Functions

    MEASUREMENT To change the unit/div settings, press Unit/div, then use the Variable knob to change the unit/div. The units that are displayed depend on which operator has been selected, and whether the probe for the selected channel has been set to voltage or current.
  • Page 76: Fft Operation

    MSO-2000E & 2000EA User Manual Frequency resolution Good Hamming Amplitude resolution Not good Frequency measurement on Suitable for..periodic waveforms Frequency resolution Very good Rectangular Amplitude resolution Bad Single-shot phenomenon Suitable for..(this mode is the same as having no window at all)
  • Page 77 MEASUREMENT 5. Press the Window key from the side menu and select the window type. Hanning, Hamming, Rectangular, Range and Blackman. 6. The FFT result represents the frequency- domain representation of a signal. Hence, the horizontal scale changes from time to frequency, and the vertical scale from voltage/current to dB/RMS.
  • Page 78: Advanced Math Overview

    MSO-2000E & 2000EA User Manual To move the FFT waveform Horizontal horizontally, press Horizontal until the Position and Scale Frequency parameter is highlighted and then use the Variable knob. 0Hz ~ half of the sampling Range frequency To select the horizontal scale of the...
  • Page 79: Advanced Math Operation

    MEASUREMENT Adds an operator or parenthesis to the function Operator expression. +, -, *, /, (, ), !(, <, >, <=, >=, ==, !=, Operator ||, && Adds a value to the expression. Figure Integers, floating point, or floating Figure point with exponent values.
  • Page 80 MSO-2000E & 2000EA User Manual 5. Press Clear to clear the expression entry area. 6. Use the Variable knob and the Select VARIABLE key to create an expression. Use the Variable knob to highlight a source, function, variable, operator, figure or measurement in orange.
  • Page 81 MEASUREMENT Example: CH1 + CH2 Source1 Advanced Math Source2 9. Press VAR1 or VAR2 to set Set the VAR1 & VAR1/VAR2 if they were used in VAR2 the expression created previously. 10. Press Mantissa. Use the Left and Right arrow keys to select a digit and use the variable knob to set the value of the selected digit.
  • Page 82 MSO-2000E & 2000EA User Manual To clear the advanced math result Clear Advanced MATH from the display, press the Math key Math again. 800.561.8187 information@itm.com www. .com...
  • Page 83: Advanced Configuration

    ADVANCED CONFIGURATION DVANCED CONFIGURATION Acquisition .......... 86 Select Acquisition Mode............86 Show Waveform in XY Mode ..........87 Set the Record Length ............89 Segmented Memory Acquisition ..91 Segments Display ..............93 Set the Number of Segments ..........94 Run Segmented Memory............95 Navigate Segmented Memory ..........97 Play Through Each Segment ..........97 Measurement on Segments ...........98 Segment Info ................
  • Page 84 MSO-2000E & 2000EA User Manual Limit Bandwidth ..............119 Expand by Ground/Center ..........120 Select Probe Type ..............121 Select Probe Attenuation Level ......... 122 Set the Deskew ..............122 Bus Key Configuration ......124 Bus Display ................124 Serial Bus Overview ............126 UART Serial Bus Configuration ........
  • Page 85 ADVANCED CONFIGURATION Copying Search Event To/From Trigger Events ..195 Search Event Navigation ........... 195 Save Search Marks ............... 196 Setting/Clearing Single Search Events ......197 FFT Peak ................198 System Settings and Miscellaneous Settings ............202 Select Menu Language ............202 View System Information ..........
  • Page 86: Acquisition

    MSO-2000E & 2000EA User Manual Acquisition The Acquisition process samples the analog input signals and converts them into digital format for internal processing. Select Acquisition Mode The acquisition mode determines how the samples Background are used to reconstruct a waveform.
  • Page 87: Show Waveform In Xy Mode

    ADVANCED CONFIGURATION 3. Select an acquisition mode from the side menu. 4. If Average was chosen, set the number of samples to be used for the average function. Mode Sample, Peak Detect, Average Average 2, 4, 8, 16, 32, 64, 128, sample Example Sample...
  • Page 88 MSO-2000E & 2000EA User Manual 1. Connect the signals to Connection Channel 1 (X-axis) and Channel 2 (Y-axis) or Channel 3 (X2-axis) and Channel 4 (Y2-axis). 2. Make sure a channel pair is active (CH1&CH2 or CH3&CH4). Press the Channel key if necessary. A channel is active if the channel key is lit.
  • Page 89: Set The Record Length

    ADVANCED CONFIGURATION To move the XY waveform position, use the vertical position knob: Channel 1 knob moves the XY waveform horizontally and Channel 2 knob moves the XY waveform vertically. Similarly, the X2 and Y2 axis can be positioned using the channel 3 and channel 4 vertical position knobs.
  • Page 90 MSO-2000E & 2000EA User Manual ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 100k ✓ ✓ ✓ ✗ ✓ ✓ ✗ ✗ Panel Operation 1. Press the Acquire key. Acquire 2. Press the Record Length key on the bottom menu and choose the record length.
  • Page 91: Segmented Memory Acquisition

    ADVANCED CONFIGURATION Segmented Memory Acquisition The advanced segmented memory utility allows the scope memory to be divided into different segments. Each time the scope is triggered, it only acquires data for one segment of memory at a time. This allows you to optimize the scope memory to only perform signal acquisition during important signal events.
  • Page 92 MSO-2000E & 2000EA User Manual Segmented memory acquisition example: Segment Segment Segment Segment Segment Segment As shown above, the memory is divided into segments to increase the number of events that can be effectively captured with the same acquisition memory. Also notice that the scope doesn’t need to rearm the trigger between each segment, this makes the segmented memory function especially useful for high speed signals.
  • Page 93: Segments Display

    ADVANCED CONFIGURATION Segments Display Progress Indicator Run/Stop Indicator Progress Indicator Indicates the number of segments that have to been captured relative to the set number of segments. Stop: The segments have finished Run/Stop Indicator acquiring or have been stopped. Run: The scope is ready to acquire segments.
  • Page 94: Set The Number Of Segments

    MSO-2000E & 2000EA User Manual Set the Number of Segments Before the Segment function can be used, set the Note trigger settings as appropriate for the signal you wish to use. The number of segments that can be used depends wholly on the record length. See page 89 to set the record length.
  • Page 95: Run Segmented Memory

    ADVANCED CONFIGURATION Run Segmented Memory Before the Segmented Memory function can be Background used, set the trigger settings as appropriate for the signal you wish to use. See page 151 for configuring the trigger settings. 1. Toggle Segments On from the bottom menu. Run Segments ...
  • Page 96 MSO-2000E & 2000EA User Manual  Alternatively, the Run/Stop key can Run/Stop be pressed. 5. The Stop Indicator will be shown when in the Stop mode. Progress Indicator Stop Indicator Segment (Stop )icon The scope is now ready to navigate or analyze the acquired segments.
  • Page 97: Navigate Segmented Memory

    ADVANCED CONFIGURATION Navigate Segmented Memory After the segmented memory acquisitions have Background been captured you can navigate through each segment one at a time. 1. Press Select Segments from the Operation bottom menu. This key will be available in the Stop mode. 2.
  • Page 98: Measurement On Segments

    MSO-2000E & 2000EA User Manual 2. Press the Play/Pause key to run through the acquired segments in numerical order. Press the Play/Pause key again  to pause the playback. When the scope has played  through to the last segment,...
  • Page 99 ADVANCED CONFIGURATION This function will bin the Statistics measurement results of a single automatic measurement into a user-defined number of bins. This allows you to easily view statistics for a large number of segments. For example, the statistics function will display the number of results for each bin and the measurement range of each bin for the selected...
  • Page 100 MSO-2000E & 2000EA User Manual 1. Press Analyze Segments from the Operation Segments menu. Note: This key will only be available in the Stop mode. 2. Press Segments Measure. 3. Select either the statistics or the measurement list from the side menu.
  • Page 101 ADVANCED CONFIGURATION Statistics Results This function will bin the measurement results of the selected automatic measurement into a user- defined number of bins. 7. To select the number of bins for the Setup statistics, press Divided by and select the number of bins with the Variable knob.
  • Page 102: Segment Info

    MSO-2000E & 2000EA User Manual Example: Measurement Measurement types List Select cursor Measurement results Segment Info 1. Press Analyze Segments from the Operation bottom menu. Note: This key will only be available in the Stop mode. 2. Press Segments Info.
  • Page 103: Display

    ADVANCED CONFIGURATION Display The Display menu defines how the waveforms and parameters appear on the main LCD display. Display Waveform as Dots or Vectors When the waveform is displayed on the screen, it Background can be displayed as dots or vectors. Panel Operation 1.
  • Page 104: Set The Intensity Level

    MSO-2000E & 2000EA User Manual 2. To set the persistence time, press the Persistence menu button on the bottom bezel. 3. Use the Variable knob to select a persistence time. 16ms, 30ms, 60ms, 120ms, 240ms, Time 0.5s, 1s, 2s,~4s, Infinite, Off...
  • Page 105: Select Display Graticule

    ADVANCED CONFIGURATION 4. To set the graticule intensity, press Graticule Graticule Intensity from the side menu and edit the Intensity intensity value. 10~100% Range Example Graticule Intensity 100% Graticule Intensity 10% 5. To set the LCD backlight intensity, press Backlight Backlight Intensity from the side menu and edit Intensity the intensity value.
  • Page 106: Freeze The Waveform (Run/Stop)

    MSO-2000E & 2000EA User Manual 3. From the side menu choose the graticule display type. Full : Shows the full grid; X and Y axis for each division. Grid : Show the full grid without the X and Y axis.
  • Page 107: Turn Off Menu

    ADVANCED CONFIGURATION POSITION Turn Off Menu PUSH TO ZERO Panel Operation 1. Press the Menu Off key below the side menu keys to reduce a menu. The menu SCALE key needs to be pressed each time to reduce one menu. See page 36 for more information.
  • Page 108: Horizontal View

    MSO-2000E & 2000EA User Manual Horizontal View This section describes how to set the horizontal scale, position, and waveform display mode. Move Waveform Position Horizontally POSITION Panel Operation The horizontal position knob moves the waveform left/right. PUSH TO ZERO As the waveform moves, a position indicator on the on the top of the display indicates the horizontal position of the waveform in memory.
  • Page 109: Select Horizontal Scale

    ADVANCED CONFIGURATION Select Horizontal Scale SCALE To select the timebase (time/div), turn Select Horizontal the horizontal Scale knob; left (slow) Scale or right (fast). Range 1ns/div ~ 100s/div, 1-2-5 increment The timebase indicator updates as the horizontal scale is adjusted. Horizontal Timebase position...
  • Page 110: Select Waveform Update Mode

    MSO-2000E & 2000EA User Manual Select Waveform Update Mode The display update mode is switched Background automatically or manually according to the timebase and trigger. Updates the whole displayed waveform at Normal once. Automatically selected when the timebase (sampling rate) is fast.
  • Page 111: Zoom Waveform Horizontally

    ADVANCED CONFIGURATION 2. Press Mode from the bottom menu and select Auto (Untriggered Roll) to let the equipment choose between Normal and Roll mode or Normal to force the update mode to Normal at all times. Zoom Waveform Horizontally When in Zoom mode, the screen is split into 2 Background sections.
  • Page 112 MSO-2000E & 2000EA User Manual Variable Position knob. VARIABLE The horizontal position will be shown on the Horizontal Position icon. Horizontal Scale To change the horizontal scale, press Horizontal Time/Div and use the Variable Position knob. VARIABLE The scale will be shown on the Horizontal Time/Div icon.
  • Page 113: Play/Pause

    ADVANCED CONFIGURATION Sensitivity Fine, Coarse To reset both the zoom and horizontal Reset the Zoom position, press Reset Zoom & H POS to & Horizontal Position To go back to the original view, press Exit Zoom the Zoom key again. Play/Pause The Play/Pause key can be used to play through Background...
  • Page 114 MSO-2000E & 2000EA User Manual 2. The scope will go into the Zoom Play mode and begin to scroll through the acquisition (from left to right). The full-record length waveform will be shown at the top and the zoomed section will be shown at the bottom.
  • Page 115 ADVANCED CONFIGURATION Speed Speed POSITION Right Left PUSH TO ZERO To reset both the zoom position and Reset the Zoom horizontal position, press Reset Zoom Position & H POS to 0s. Press the Play/Pause key to pause or Pause resume playing the waveform. Reverse Direction Press the Play/Pause key when at the end of the record length to play back through the waveform in reverse.
  • Page 116: Vertical View (Channel)

    MSO-2000E & 2000EA User Manual Vertical View (Channel) This section describes how to set the vertical scale, position, and coupling mode. Move Waveform Position Vertically POSITION Panel Operation 1. To move the waveform up or down, turn the vertical position knob for each channel.
  • Page 117: Select Vertical Scale

    ADVANCED CONFIGURATION Select Vertical Scale SCALE Panel Operation To change the vertical scale, turn the vertical SCALE knob; left (down) or right (up). The vertical scale indicator on the bottom left of the display changes accordingly for the specific channel. 1mV/div ~ 10V/div.
  • Page 118: Input Impedance

    Observing the AC portion of the waveform using AC coupling DC coupling AC coupling Input Impedance The input impedance of the MSO-2000E/2000EA is Background fixed at 1MΩ. The impedance is displayed in the channel menu. View Impedance 1. Press the Channel key.
  • Page 119: Limit Bandwidth

    ADVANCED CONFIGURATION Limit Bandwidth Bandwidth limitation puts the input signal into a Background selected bandwidth filter. This function is useful for cutting out high frequency noise to see a clear waveform shape. The bandwidth filters available are dependent on the bandwidth of the oscilloscope model. Also refer to the digital filter application, page 270.
  • Page 120: Expand By Ground/Center

    MSO-2000E & 2000EA User Manual Expand by Ground/Center When the voltage scale is changed, the Expand Background function designates whether the signal expands from the center of the screen or from the signal ground level. Expand by center can be used to easily see if a signal has a voltage bias.
  • Page 121: Select Probe Type

    ADVANCED CONFIGURATION Expand by Ground Expand by Ground Expand by Center Expand by Center Select Probe Type A signal probe can be set to voltage or current. Background Panel Operation 1. Press the Channel key. 2. Press Probe from the bottom menu. 3.
  • Page 122: Select Probe Attenuation Level

    MSO-2000E & 2000EA User Manual Select Probe Attenuation Level An oscilloscope probe has an attenuation switch to Background lower the original DUT signal level to the oscilloscope input range, if necessary. The probe attenuation selection adjusts the vertical scale so that the voltage level on the display reflects the real value on a DUT.
  • Page 123 ADVANCED CONFIGURATION 3. Press Deskew on the side menu and use the Variable knob to set the deskew time. Alternatively, press Set to 0s to reset the deskew time. -50ns~50ns, 10ps increments Range 4. Repeat the procedure for another channel if necessary.
  • Page 124: Bus Key Configuration

    MSO-2000E & 2000EA User Manual Bus Key Configuration The Bus key is used to configure the Serial bus and parallel bus inputs. The bus inputs can be either analog or digital. The Bus menu also features event tables to track and save your bus data.
  • Page 125 ADVANCED CONFIGURATION Parallel All read words are shown in purple (no clock) or white (a clock is defined among the channels). CAN: Purple = Error frame, Data length control (DLC), Overload. Yellow = Identifier. Cyan = Data. Orange = CRC. Red = Bit stuffing error LIN: Purple = Break, Sync and Checksum...
  • Page 126: Serial Bus Overview

    MSO-2000E & 2000EA User Manual Serial Bus Overview The Serial Bus includes support for 5 common serial interfaces UART, I C, SPI, Parallel, CAN and LIN. Each interface is fully configurable to accommodate variations in the basic protocols. Each input can be displayed as binary, hexadecimal or ASCII. An event table can also be created to aid in debugging.
  • Page 127 ADVANCED CONFIGURATION The SPI (Serial Interface Peripheral) bus is fully configurable to accommodate the wide variety of SPI interfaces. This bus is only available on 4 channel models. SCLK, SS, MOSI, MISO Inputs SCLK, SS, MOSI, MISO Threshold Configuration SCLK edge, SS logic level, Word size, Bit order SS Active, MOSI, MISO, Trigger On...
  • Page 128: Uart Serial Bus Configuration

    MSO-2000E & 2000EA User Manual UART Serial Bus Configuration The UART bus menu is designed to decode RS-232 and other common RS-232 variants such as RS-422, RS-485. The software configuration is also flexible enough to decode the many proprietary protocols based on RS-232.
  • Page 129 ADVANCED CONFIGURATION 3. Press Bus from the bottom menu and choose the UART serial bus on the side menu. 4. Press either Analog Source or Digital Source to choose whether the sources for the UART bus are analog or digital. 5.
  • Page 130: C Serial Bus Interface

    MSO-2000E & 2000EA User Manual Baud Rate 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2000, 2400, 3600, 4800, 7200, 9600, 14400, 15200, 19200, 28800, 31250, 38400, 56000, 57600, 76800, 115200, 128000, 230400, 460800, 921600, 1382400, 1843200, 2764800 Data Bits 8 (fixed)
  • Page 131 ADVANCED CONFIGURATION Analog SCLK Digital 2. Press the Bus key. 3. Press Bus from the bottom menu and choose I C from the side menu. 4. Press either Analog Source or Digital Source to choose whether the sources for the I C bus are analog or digital.
  • Page 132: Spi Serial Bus Interface

    MSO-2000E & 2000EA User Manual SPI Serial Bus Interface The serial peripheral interface (SPI) is a full duplex 4 wire synchronous serial interface. The 4 signals lines: Serial clock line (SCLK), slave select (SS), Master output/slave input (MOSI, or SIMO) and the Master input/slave output (MISO, or SOMI). The word size is configurable from 4 to 32 bits.
  • Page 133 ADVANCED CONFIGURATION 5. Press Define Inputs from the lower Define Inputs menu. 6. From the side menu choose the SCLK, SS, MOSI and MISO inputs. CH1~CH4 or D0~D15 * SCLK CH1~CH4 or D0~D15 * OFF, CH1~CH4 or OFF, D0~D15 * MOSI OFF, CH1~CH4 or OFF, D0~D15 * MISO...
  • Page 134: Can Serial Bus Interface

    The CAN bus is a multi-master communication system that relies on arbitration to solve contention issues. The MSO-2000E supports both CAN 2.0A and 2.0B. The CAN bus uses two wires, CAN-High and CAN-Low. These wires are voltage inverted, and as such, the MSO-2000E/2000EA only needs one wire, CAN-High or CAN-Low for decoding.
  • Page 135 ADVANCED CONFIGURATION 5. Press Define Inputs from the lower Define Inputs menu. 6. From the side menu choose the CAN Input inputs and the signal type. CAN Input CH1~CH4 or D0~D15 * CAN_H, CAN_L, Tx, Rx. Signal Type *Depending on your choice at step 4 above. The Sample Point soft-key indicates the sampling Note position of each bit.
  • Page 136: Lin Serial Bus Interface

    MSO-2000E & 2000EA User Manual LIN Serial Bus Interface The local interconnect network (LIN) bus is a single wire interface. 1. Connect the bus signal (LIN Input) to one of the Panel operation oscilloscope’s analog or digital channels. Connect the ground potential to one of the probes’...
  • Page 137 ADVANCED CONFIGURATION LIN Input CH1~CH4 or D0~D15 * Normal (High = 1), Polarity Inverted(High = 0) *Depending on your choice at step 4 above. The Sample Point soft-key indicates the sampling Note position of each bit. This parameter is fixed. The Configure menu sets the bit rate, the LIN Configuration standard and the parity options for the Id frame.
  • Page 138: Parallel Bus

    MSO-2000E & 2000EA User Manual Parallel Bus The digital channels can be configured as a parallel bus. The number of bits that defines the bus as well as which bit is used as the bus clock can also be configured. The trigger should also be set to parallel bus.
  • Page 139 ADVANCED CONFIGURATION 5. Press Number of Bits from the side menu and select the number of bits for the data bus. By default the bus will assign bit 0 to D0, bit 1 to D1, and so on up to the last bit.
  • Page 140: Bus Decoding

    MSO-2000E & 2000EA User Manual Bus Decoding The bus that is displayed on the screen or in the Background event tables can be set to either hex or binary formats. Press Bus Display from the Bus Operation menu and choose either Hex or Binary from the side menu.
  • Page 141 ADVANCED CONFIGURATION 1.4V 2.5V 5.0V CMOS 1.65V 3.3V CMOS 1.25V 2.5V CMOS -1.3V 3.7V PECL 4. Press Threshold to set a user defined threshold for the currently selected input. For the analog channels, the threshold level depends on the vertical scale : Scale Range Scale...
  • Page 142: Serial Or Parallel Bus Event Tables

    MSO-2000E & 2000EA User Manual Serial or Parallel Bus Event Tables The serial bus event tables list when each data Background event on the bus occurred. The data is displayed as either hex or binary, depending on the bus display settings.
  • Page 143 ADVANCED CONFIGURATION Save Event Table 4. To save the event table, press Save Event Table. The Event table will be saved to the current file path in a CSV format. See page 146 for details. Use the variable knob to scroll through the event table.
  • Page 144 MSO-2000E & 2000EA User Manual Example: Time of trigger Address C Data Detail Select cursor Data at cursor position Note Data Detail is only available with the I C bus. Example: MOSI MISO Time of trigger SPI Event table Select cursor...
  • Page 145 ADVANCED CONFIGURATION Example: Identifier Data Errors Time of trigger Parity Checksum LIN Event table Select cursor Example: Time of event Parallel Bus Event table Event data 800.561.8187 information@itm.com www. .com...
  • Page 146: Event Tables Format

    MSO-2000E & 2000EA User Manual Event Tables Format Each bus type (UART, I C, SPI, Parallel, CAN and LIN) can have an event table saved containing each bus event as a .CSV file. An event is defined as a packet/frame/word or associated set of data being successfully read according to the specific operating conditions of each bus (Start of frame, acknowledgements, checksums, etc …).
  • Page 147: Adding A Label To A Bus

    ADVANCED CONFIGURATION Example Below shows the data associated with an SPI event table in a spreadsheet. Time MOSI MISO -11.60us 0D87 0D87 -10.16us 06C0 06C0 -8.720us 8343 -7.282us 243 -5.840us 0C88 0C88 Adding a Label to a Bus A Label can be added to the buses. This label will Background appear next to the bus indicator on the left hand- side of the display.
  • Page 148 MSO-2000E & 2000EA User Manual 4. The Edit Label window appears. 5. Use the Variable knob to highlight a character. VARIABLE Press Enter Character to select a number or letter. Press Back Space to delete a character. Press Editing Completed to create the new label and return to the previous menu.
  • Page 149: Using Cursors With The Serial Or Parallel Bus

    ADVANCED CONFIGURATION 6. The label will appear next to the bus indicator. Below, the label “ACK” was created for the bus. The bus is labeled as ACK Press Label Display to toggle the label Remove Label on or off. Using Cursors with the Serial or Parallel Bus The cursors can be used to read bus values at any Background position.
  • Page 150 MSO-2000E & 2000EA User Manual 3. The cursor position information appears on the top left hand side of the screen. Example: I C cursors. Hor. position, Bus value(s) Cursor Hor. position, Bus value(s) Cursor 4. Use the Variable knob to move the VARIABLE movable cursor(s) left or right.
  • Page 151: Trigger

    ADVANCED CONFIGURATION Trigger The trigger configures the conditions for when the MSO- 2000E/2000EA captures a waveform. Trigger Type Overview The edge trigger is the simplest trigger type. An Edge edge trigger triggers when the signal crosses an amplitude threshold with either a positive or negative slope.
  • Page 152 MSO-2000E & 2000EA User Manual Delay trigger example (by time) Edge trigger Delay Source Delay time length First triggering point Triggers when the pulse width of the signal is less Pulse Width than, equal, not equal or greater than a specified pulse width.
  • Page 153: Trigger: Types And Sources

    ADVANCED CONFIGURATION Triggers when the signal stays high, low or either Timeout for a designated amount of time. The trigger level determines when a signal is high or low. Trigger level threshold Timer Triggering point Triggers on SPI, UART, I2C, Parallel, CAN or LIN bus events.
  • Page 154: Trigger Parameter Overview

    MSO-2000E & 2000EA User Manual *Only for two channels model. **The source (analog or digital) is assigned from the Bus menu. Trigger Parameter Overview All the following parameters are common for all the trigger types unless stated otherwise. Channel 1 ~ 4 input signals...
  • Page 155 The Source Bus is not configurable from the Trigger Note menu. The field is automatically filled according to the Bus menu configuration (see page 124). The MSO-2000E/2000EA generates an Trigger Mode Auto (un- internal trigger if there is no trigger...
  • Page 156 MSO-2000E & 2000EA User Manual DC coupling. Coupling (Edge, Delay, AC coupling. Blocks DC components Timeout) from the trigger circuits *. High frequency filter, above 70kHz *. HF reject Low frequency filter, below 70kHz *. LF reject Reject noise DC coupling with low sensitivity to reject noise.
  • Page 157 ADVANCED CONFIGURATION Press Choose Preset to Choose select a pre-set logic Preset threshold. Threshold Logic Type 1.4V 2.5V 5.0V CMOS 1.65V 3.3V CMOS 1.25V 2.5V CMOS -1.3V 3.7V PECL Setting the trigger levels for the digital sources will Note also change the threshold levels set in the Logic Analyzer menu (page 217).
  • Page 158 MSO-2000E & 2000EA User Manual Sets the amplitude threshold level for the pulse Threshold widths. (Pulse Width) –XXV ~ +XXV, user-set level Threshold 1.4V Set to TTL -1.3V Set to ECL Set to 50% Sets the threshold to 50% (Only when the trigger source is digital):...
  • Page 159 ADVANCED CONFIGURATION SEquential Couleur A Memoire SECAM Positive polarity (triggered on the high Polarity to low transition) (Pulse Width, Negative polarity (triggered on the low Video) to high transition) Positive polarity (positive runt) Polarity (Pulse Runt) Negative polarity (negative runt) Either (either negative or positive runt) Selects the trigger point in the video signal.
  • Page 160 MSO-2000E & 2000EA User Manual Selects the conditions for the parallel bus trigger. Data (Bus) A Binary or Hexadecimal word. Parallel Sets the upper threshold limit. Threshold (Pulse Runt) Sets the lower threshold limit. Sets the High threshold. Threshold (Rise & Fall) Sets the Low threshold.
  • Page 161: Setup Holdoff Level

    Setup Holdoff Level The holdoff function defines the waiting period Background before the MSO-2000E/2000EA starts triggering again after a trigger point. The holdoff function ensures a stable display if there are a number of points in a periodic waveform that can be triggered.
  • Page 162: Setup Trigger Mode

    MSO-2000E & 2000EA User Manual Setup Trigger Mode The trigger mode can be set to Normal or Auto Background (untriggered roll). The triggering mode applies to all the trigger types. Panel Operation 1. Press the Trigger menu key. Menu 2. Press Mode from the bottom menu to change the triggering mode.
  • Page 163 ADVANCED CONFIGURATION Channel 1 ~ 4 (Alternate On/Off), Range EXT (Ext Probe: Volt/Current, Attenuation: 1mX~1kX, CH2 models only), AC Line, D0 ~ D15. 6. Press Coupling from the bottom bezel menu to select the trigger coupling or frequency filter settings. Choose the coupling from the side menu.
  • Page 164: Using Advanced Delay Trigger

    MSO-2000E & 2000EA User Manual 10. Set the external trigger level using the side menu. 00.0V~ 5 screen divisions Analog channel Set to TTL 1.4V Range Set to ECL -1.3V Set to 50% -5.00V~ +5.00V Digital channel 1.4V Range 5.0V CMOS 2.5V...
  • Page 165 ADVANCED CONFIGURATION 4. Select Delay from the side menu. The delay trigger indicator appears at the bottom of the display. From left: Delay trigger indicator (D), edge trigger (A), edge slope, edge level, edge coupling, delay trigger (B), delay slope, delay trigger level, delay coupling.
  • Page 166: Using Pulse Width Trigger

    MSO-2000E & 2000EA User Manual 8. To Delay by Time (Duration), press Time from the side menu and set the delay time. 4ns ~ 10s (by time) Range Set to minimum 9. To Delay by Event, press Event from the side menu and set the number of events.
  • Page 167 ADVANCED CONFIGURATION 5. Use the side menu to select the pulse width trigger source. Channel 1 ~ 4 (Alternate On/Off), Range EXT (Ext Probe: Volt/Current, Attenuation: 1mX~1kX, CH2 models only), AC Line, D0 ~ D15. 6. Press Polarity to toggle the polarity type.
  • Page 168 MSO-2000E & 2000EA User Manual 9. Set the threshold level using the side menu. 00.0V~ 5 screen divisions Analog channel Set to TTL 1.4V Range Set to ECL -1.3V Set to 50% -5.00V~ +5.00V Digital channel 1.4V Range 5.0V CMOS 2.5V...
  • Page 169: Using Video Trigger

    ADVANCED CONFIGURATION Using Video Trigger Panel Operation 1. Press the trigger Menu key. Menu 2. Press the Type key from the lower bezel menu. 3. Select Video from the side menu. The video trigger indicator appears at the bottom of the display. From left: source, video standard, field, line, coupling 4.
  • Page 170: Pulse Runt Trigger

    MSO-2000E & 2000EA User Manual 7. Press Trigger On to edit the video field and line. Use the side menu to select the field and line. Odd Field NTSC: 1 ~ 263 PAL/SECAM: 1 ~ 313 EDTV: 1~525(480P), 1~625(576P) HDTV: 1~750(720P), 1~563(1080i),...
  • Page 171 ADVANCED CONFIGURATION From left: polarity, source, high/low threshold, threshold level, coupling 4. Press Source from the lower menu. Use the side menu to select a source. Channel 1 ~ 4(Alternate On/Off) Range 5. Press Polarity to toggle the polarity. Rising edge, falling edge, either. Range 6.
  • Page 172: Using Rise And Fall Trigger

    MSO-2000E & 2000EA User Manual Using Rise and Fall Trigger Panel Operation 1. Press the trigger Menu key. Menu 2. Press the Type key from the lower bezel menu. 3. Select Others  Rise and Fall from the side menu.
  • Page 173: Using The Timeout Trigger

    ADVANCED CONFIGURATION 4ns ~ 10s Width 7. Press Threshold from the lower bezel to edit the High and Low threshold. High: -XXV~XXV Range Low: -XXV~XXV Using the Timeout Trigger Panel Operation 1. Press the trigger Menu key. Menu 2. Press the Type key from the lower bezel menu.
  • Page 174 MSO-2000E & 2000EA User Manual 5. Press Coupling from the bottom bezel menu to select the trigger coupling or frequency filter settings. Choose the coupling from the side menu. DC, AC, HF Reject, LF Reject Range 6. Toggle Noise Rejection On or Off from the Coupling side menu.
  • Page 175 ADVANCED CONFIGURATION 9. Set the level using the side menu. 00.0V~ 5 screen divisions Analog channel Set to TTL 1.4V Range Set to ECL -1.3V Set to 50% -5.00V~ +5.00V Digital channel 1.4V Range 5.0V CMOS 2.5V 3.3V CMOS 1.65V 2.5V CMOS 1.25V -1.3V...
  • Page 176: Using The Bus Trigger

    MSO-2000E & 2000EA User Manual Using the Bus Trigger The Bus trigger is used to trigger the oscilloscope on UART, I2C, SPI, CAN or LIN serial bus signals or on parallel bus data. UART BUS Trigger Settings The UART bus trigger conditions can be set at any time after the bus settings have been set to UART.
  • Page 177: I 2 C Bus Trigger Settings

    ADVANCED CONFIGURATION If Tx Data or Rx Data was configured for the Trigger On – Tx Trigger On setting, then the number of bytes and Data, Rx Data data can also be configured. 6. Press Data from the bottom menu. 7.
  • Page 178 MSO-2000E & 2000EA User Manual 3. Press Type from the bottom menu. 4. Press Others from the side menu and select Bus. The Trigger on settings will be reflected on the Trigger Configuration icon. From left: Bus trigger, Trigger source 5.
  • Page 179 ADVANCED CONFIGURATION 9. Press Data from the side menu to edit the triggering data. To edit the data, use the Variable VARIABLE knob to highlight a binary or hex digit and press Select. Use the Variable knob to choose a value for the digit and press Select to confirm.
  • Page 180 MSO-2000E & 2000EA User Manual 12. To choose a preset address as the default address, press Choose Preset and select a preset address. Description Address General Call 0000 000 0 START Byte 0000 000 1 Hs-mode 0000 1XX X EEPROM...
  • Page 181: Spi Bus Trigger Settings

    ADVANCED CONFIGURATION SPI Bus Trigger Settings The SPI bus trigger conditions can be set at any time after the bus setting has been set to SPI. Panel Operation 1. Set the Bus to SPI in the bus menu. Page 132 2.
  • Page 182: Can Bus Trigger

    MSO-2000E & 2000EA User Manual 7. Press Number of Words from the side menu and choose the number of words for the data. 1~32 Words 8. Press MOSI or MISO from the side menu to edit the triggering data. To edit the data, use the Variable...
  • Page 183 ADVANCED CONFIGURATION The Trigger on settings will be reflected on the Trigger Configuration icon. From left: Bus trigger, Trigger source 5. Press Trigger On and select the triggering condition for the selected bus. Trigger On Start of Frame, Type of Frame, Identifier, Data, Id &...
  • Page 184 MSO-2000E & 2000EA User Manual 9. Press Direction on the bottom menu and select the CAN Direction from the side menu. CAN Direction Write, Read, Read or Write If Data/Id and Data was configured for the Trigger On - Data Trigger On setting, then the triggering data must be configured.
  • Page 185: Lin Bus Trigger

    ADVANCED CONFIGURATION 14. The oscilloscope will now trigger when the specified bus data matches the Trigger When conditions. LIN Bus Trigger The LIN bus trigger conditions can be set at any time after the bus setting has been set to LIN. Panel Operation 1.
  • Page 186 MSO-2000E & 2000EA User Manual 7. Press Identifier from the side menu to set the identifier data. To edit the identifier, use the VARIABLE Variable knob to highlight a binary or hex digit and press Select. Use the Variable knob to choose a value for the digit and press Select to confirm.
  • Page 187: Parallel Bus Trigger

    ADVANCED CONFIGURATION 11. Press Trigger When from the side menu to choose the triggering condition for the data. When =, ≠, <, >, ≤, ≥ 12. The oscilloscope will now trigger when the specified bus data matches the Trigger When conditions.
  • Page 188: Using The Logic Trigger

    MSO-2000E & 2000EA User Manual 6. Press Data from the side menu to edit the triggering data. To edit the data, use the Variable VARIABLE knob to highlight a binary or hex digit and press Select. Use the Variable knob to choose a value for the digit and press Select to confirm.
  • Page 189 ADVANCED CONFIGURATION From left: Bits D15~D0 4. Press Define inputs from the bottom menu. 5. Press Select on the side menu and select a channel. 6. Next, select a logic level for the selected channel, or set the selected channel as the clock signal.
  • Page 190 MSO-2000E & 2000EA User Manual If a channel was selected as a clock signal, then the Logic Trigger clock edge determines when the logic comparison Timing is made. If a clock was not defined then the When menu determines the triggering timing conditions.
  • Page 191 ADVANCED CONFIGURATION 10.0ns ~ 9.99s. Triggers when Is True ≠ the defined logic is not true for the defined amount of time ±5% (falling edge). 11. The oscilloscope will now trigger when the specified logic appears among the digital channels. The trigger threshold levels for the digital channels Trigger Threshold can be assigned from a selected number of preset...
  • Page 192 MSO-2000E & 2000EA User Manual 15. Press Threshold to set a user defined threshold. ± 5.00V Range 800.561.8187 information@itm.com www. .com...
  • Page 193: Search

    ADVANCED CONFIGURATION Search The search feature can be used to search for events on the analog and digital input channels. The events that can be searched for are similar to the events that are used for the trigger system. The only difference is that the search feature uses the measurement threshold levels rather than the trigger level to determine events.
  • Page 194 MSO-2000E & 2000EA User Manual Panel Operation 1. Press the Search menu key. Search 2. Press Search from the bottom menu and turn the Search function on. 3. Press Search Type from the bottom menu and select the type of search.
  • Page 195: Copying Search Event To/From Trigger Events

    ADVANCED CONFIGURATION Copying Search Event To/From Trigger Events As the trigger system and search feature have Background similar settings, their settings can be used interchangeably by using the Copy functions. Interchangeable Edge, Pulse Width, Pulse Runt, Rise and Fall Times, Settings Logic and Bus (FFT Peak has no trigger equivalent) Panel Operation 1.
  • Page 196: Save Search Marks

    MSO-2000E & 2000EA User Manual 2. Search events are marked by hollow white triangles at the top of the graticule. 3. Use the search arrow keys to move between each search event. Search events can be navigated in both stop and run mode.
  • Page 197: Setting/Clearing Single Search Events

    ADVANCED CONFIGURATION To clear all the saved marks, press Clear All Marks Clear All Marks from the side menu. Each time the Save All Marks function is used, the Note previously saved marks will also be retained, unless cleared. Setting/Clearing Single Search Events In addition to searching for search events based on Background Search Type settings, custom search marks can be...
  • Page 198: Fft Peak

    MSO-2000E & 2000EA User Manual FFT Peak The FFT Peak search type can be used to mark all Background FFT peaks that are above a certain threshold. Search events Threshold level Number of events or peak amplitude The search function can support up to 10,000 events,...
  • Page 199 ADVANCED CONFIGURATION 6. Next, select the event search method by pressing Method from the bottom menu. Select Max Peak to search by a selected number of “max” peaks. Select Level to set the threshold level for the search events. Any peaks above the threshold level will be seen as a search event.
  • Page 200 MSO-2000E & 2000EA User Manual Peak Event Table The Event Table function tabulates the amplitude and frequency of each peak event in real time. The event table can also be saved to a USB disk drive. File names are saved as a PeakEventTbXXXX.csv, where XXXX is a number starting from 0001 and is incremented each time the event table is saved.
  • Page 201 ADVANCED CONFIGURATION The format for the CSV file is the same as the event Event Table CSV table displayed on the MSO-2000E/2000EA screen; Format No., Frequency, and Value. For example: Frequency Value 1.0000MHz -29.6dB 2.0000MHz -30.4dB 3.0000MHz -32.0dB To shift the peak events to the...
  • Page 202: System Settings And Miscellaneous Settings

    This section describes how to set the interface, language, time/date, probe compensation signal, erase the internal memory and access useful QR codes. Select Menu Language The MSO-2000E/2000EA has a number of different Description languages to choose from. Panel Operation 1. Press the Utility key.
  • Page 203: View System Information

    ADVANCED CONFIGURATION View System Information Panel Operation 1. Press the Utility key. Utility 2. Press System from the lower menu. 3. Press System Info from the side menu. A display panel will appear showing: Manufacturer name Model name   Serial number Firmware version ...
  • Page 204: Set Date And Time

    MSO-2000E & 2000EA User Manual 2. Press System from the lower menu. 3. Press Erase Memory from the side menu. A message will prompt you to press Erase Memory again to confirm the process. Pressing any other key will cancel erasing the memory.
  • Page 205: Probe Compensation Frequency

    ADVANCED CONFIGURATION 5. Make sure the date/time setting is correctly reflected at the top of the display. Probe Compensation Frequency The probe compensation Background Compensation output output can be set from 1kHz (default) to 200kHz, in steps of 1kHz. 1. Press the Utility key. Panel Operation/ Utility Parameter...
  • Page 206 MSO-2000E & 2000EA User Manual GW Instek website QR Code Items  GW Instek contact window (marketing  department) 1. Press the Utility key. Panel Operation/ Utility Parameter 2. Press System from the lower menu. 3. Press More 1 of 3, More 2 of 3 from the side menu.
  • Page 207: Logic Analyzer

    LOGIC ANALYZER OGIC ANALYZER Logic Analyzer Operation ....208 Overview ................208 Using the Logic Analyzer Probes ........209 Digital Display Overview ........... 210 Activating Digital Channels ..........211 Activate Digital Channels as a Group ............ 211 Activate Individual Channels ..............212 Moving the Digital Channels or Creating Digital Channel Groups ..
  • Page 208: Logic Analyzer Operation

    MSO-2000E & 2000EA User Manual Logic Analyzer Operation Overview The logic analyzer inputs can be used to measure Background discrete inputs or can be used to measure values on a parallel or serial bus. The logic analyzer has a sample rate of 1GSa/s with a bandwidth of 200MHz.
  • Page 209: Using The Logic Analyzer Probes

    LOGIC ANALYZER Using the Logic Analyzer Probes This section will describe how to connect the Background digital channels to the device under test. 1. Turn the DUT off to protect it from being short Connection circuited when the probes are attached. 2.
  • Page 210: Digital Display Overview

    MSO-2000E & 2000EA User Manual Digital Display Overview Analog waveform indicator Analog waveform Digital channel group Digital waveforms Digital channel indicators Used to show the position of the analog waveform Analog Waveform outputs. Indicator Currently active Activated analog analog waveform (solid...
  • Page 211: Activating Digital Channels

    LOGIC ANALYZER Activating Digital Channels The digital channels can be initially turned on in groups of 8 or individually. Activate Digital Channels as a Group The digital channels can be turned on or off in Background groups of eight, D0~D7 and D8~D15. Panel Operation 1.
  • Page 212: Activate Individual Channels

    MSO-2000E & 2000EA User Manual Activate Individual Channels Each digital channel or group can be turned on or Background off individually. Panel Operation 1. Press the Select soft-key. 2. Use the variable knob to highlight VARIABLE a channel or a group.
  • Page 213: Moving The Digital Channels Or Creating Digital Channel Groups

    LOGIC ANALYZER Channels can also be selected just by turning the Note variable knob when the mode is set to LA move mode. In this mode the selected channel or group will be shown on the Select soft-key. However this method will only show those channels/groups that have already been turned on.
  • Page 214 MSO-2000E & 2000EA User Manual Below, channel 4 is selected. Channel 4 is selected Note: If the Variable knob cannot select a channel, press the Select key to toggle the scope into 'LA Select mode'. 3. Press the Select key. The mode...
  • Page 215 LOGIC ANALYZER 4. Use the variable knob to position VARIABLE the selected channel/group: If you position the channel indicator over the next/previous channel, it will split the group into 2. Split the group above the selected channel: Split the group below the selected channel: 800.561.8187 information@itm.com www.
  • Page 216 MSO-2000E & 2000EA User Manual If you continue to move the channel indicator past the next/previous channel, it will move the indicator anywhere within that group. 5. If you move the indicator outside of the group, it will remove the selected channel from the group.
  • Page 217: Digital Channel Vertical Scale

    D0~D3, D4~7, D8~D11 and D12~D15. Each group can have a different threshold level. The MSO-2000E/2000EA has 7 preset threshold levels and a user-defined threshold. A user- defined threshold level can be set for each group. Any signal over the threshold level corresponds to a high (1);...
  • Page 218 MSO-2000E & 2000EA User Manual 3. Press Choose Preset to select a pre- set logic threshold. Threshold Logic Type 1.4V 2.5V 5.0V CMOS 1.65V 3.3V CMOS 1.25V 2.5V CMOS -1.3V 3.7V PECL 4. Press Threshold to set a user defined threshold for the currently selected group.
  • Page 219: Analog Waveform

    LOGIC ANALYZER Analog Waveform The analog waveform function combines the Background digital channel inputs into two 8-bit analog waveforms. The analog waveforms are created from the digital channel groups D0~7 and D8~15. Example 1. Press the Option key. Panel Operation Option 2.
  • Page 220: Adding Labels To Digital Channels Or The Analog Waveform

    MSO-2000E & 2000EA User Manual Set Vertical Scale 6. Press Vertical until the X scale parameter is highlighted. Use the Variable knob to set the scale. 7. Press Edit Labels to edit the label Edit Labels for the currently selected analog waveform.
  • Page 221 LOGIC ANALYZER ACK, AD0, ADDR, ANALOG, Labels BIT, CAS, CLK, CLOCK, CLR, COUNT, DATA, DTACK, ENABLE, HALT, INT, IN, IRQ, LATCH, LOAD, NMI 4. Press Edit Character to edit the Edit Label current label. 5. The Edit Label window appears. 6.
  • Page 222 MSO-2000E & 2000EA User Manual Press Editing Completed to create the new label and return to the previous menu. Note: this key must be pressed to create a label, even for a preset label. Press Cancel to cancel the editing and return to the Edit Label menu.
  • Page 223: Arbitrary Wave Generator

    ARBITRARY WAVE GENERATOR RBITRARY WAVE GENERATOR Arbitrary Wave Generator Operation .. 224 Overview ................224 Rear Panel ................225 AWG Display Overview ............ 226 Generator Connection ............226 Output Setup ................ 227 Select the Active Channel ................. 227 Turn the Output On for the Selected Channel ........228 Setting the Load Impedance ..............
  • Page 224: Arbitrary Wave Generator Operation

    MSO-2000E & 2000EA User Manual Arbitrary Wave Generator Operation Overview The AWG is a full-function dual channel arbitrary Background waveform generator. It is available on the MSO- 2000EA only. Arbitrary, Sine, Square, Pulse, Ramp, DC, Noise, Waveforms Sinc, Gaussian, Lorentz, Exp. Rise, Exp. Fall,...
  • Page 225: Rear Panel

    ARBITRARY WAVE GENERATOR Rear Panel GEN2 output GEN1 output GEN 2 GEN 1 Ser. No. Label LINE VOLTAGE AC 100 240V RANGE CAUTION FREQUENCY 60Hz TO AVOID ELECTRIC SHOCK THE POWER CORD PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED TO GROUND. POWER MAX.
  • Page 226: Awg Display Overview

    MSO-2000E & 2000EA User Manual AWG Display Overview State Display generator status The state display is used to visually show the State Display major channel settings when you are in the AWG menu. AWG Generator The AWG channel status indicators show the Status Indicators active channels, output waveforms and function.
  • Page 227: Output Setup

    ARBITRARY WAVE GENERATOR 1. Connect the BNC output (GEN1 or GEN2) to Connection the DUT using the GTL-101 BNC-Alligator clip cables. GEN1 GEN2 Output Setup The Output Setup menu allows you to select a channel, to turn the output on or off for the selected channel, configure the load impedance and the phase of the output.
  • Page 228: Turn The Output On For The Selected Channel

    MSO-2000E & 2000EA User Manual 4. Press Select from the side menu and choose GEN1 or GEN2. Turn the Output On for the Selected Channel The output for each generator channel can be Background turned on or off independently. Panel Operation 1. Press Output to toggle the selected channel on or off.
  • Page 229: Gen1 And Gen2 Setup

    ARBITRARY WAVE GENERATOR GEN1 and GEN2 Setup The GEN1 Setup and GEN2 Setup select the output waveform, waveform settings (amplitude, frequency, offset), modulation mode or allow you to create arbitrary waveforms. Selecting a Waveform The AWG option has 14 selectable waveforms, Background including a user-created arbitrary waveform.
  • Page 230: Waveform Settings

    MSO-2000E & 2000EA User Manual Arbitrary, sine, square, pulse, Selectable ramp, DC, Noise, Sinc, waveforms Gaussian, Lorentz, Exp. Rise, Exp. Fall, Haversine, Cardiac. Waveform Settings The Waveform Settings sub menu selects the Background Frequency, amplitude and offset settings for currently selected waveform in the GEN1 or GEN2 Setup menu.
  • Page 231 ARBITRARY WAVE GENERATOR 4. Use the Left and Right arrow keys to select a base unit and use the variable knob to increase the amplitude by that base unit, as shown in the Amplitude window. 5. Default can be pressed to set the amplitude to 1.00Vpp.
  • Page 232 MSO-2000E & 2000EA User Manual 8. Use the Left and Right arrow keys to select a base unit and use the variable knob to increase the offset by that base unit, as shown in the Offset window. 9. Default can be pressed to set the Offset to 0.00Vdc.
  • Page 233: Am Modulation

    ARBITRARY WAVE GENERATOR AM Modulation Amplitude modulation can be used for either Background channel. All waveforms except Noise and DC can be used as the carrier wave. Sine, square, pulse, ramp and noise can be selected as the modulating waveform. Example 1.
  • Page 234 MSO-2000E & 2000EA User Manual 2. Press the Modulation from the bottom menu. 3. From the side menu, turn Modulation on. 4. Press AM to select AM modulation and to enter the AM modulation setup menu. 5. Press Depth to set the modulation...
  • Page 235: Fm Modulation

    ARBITRARY WAVE GENERATOR 10. Press Symmetry to set the Symmetry symmetry (pulse wave). (Ramp wave only) 0% ~ 100% Symmetry 11. Press Rate to set the rate (noise Rate wave). (Noise wave only) 1kHz ~ 10MHz Noise Exit AM Settings 12. Press Go Back to exit the AM settings.
  • Page 236 MSO-2000E & 2000EA User Manual Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively. Press Waveform from the bottom menu. Select the waveform from the side menu. This will be the carrier wave. Carrier Waves Sine, square, ramp 2.
  • Page 237: Fsk Modulation

    ARBITRARY WAVE GENERATOR 8. Press Phase to set the phase of the Phase modulated wave (sine wave). (Sine wave only) -180.0° ~ 180.0° Phase 9. Press Duty Cycle to set the duty Duty Cycle cycle (pulse wave). (Pulse wave only) 1.0% ~ 99.0% Duty Cycle 10.
  • Page 238 MSO-2000E & 2000EA User Manual Example 1. Select the carrier waveform from the GEN1 Panel Operation Setup/GEN2 Setup menu: Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively. Press Waveform from the bottom menu. Select the waveform from the side menu. This will be the carrier wave.
  • Page 239: Sweep

    ARBITRARY WAVE GENERATOR Set the Hop Freq 5. Press Hop Freq to set the hop frequency. 25MHz ~ 0.1Hz Hop Freq 6. Press FSK Rate to set the rate at FSK Rate which the waveform switches from the carrier and hop frequency. 1Hz ~ 200kHz FSK Rate Exit FSK Settings 7.
  • Page 240 MSO-2000E & 2000EA User Manual Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively. Press Waveform from the bottom menu. Select the waveform from the side menu. Sweep Waves Sine, square, ramp. 2. Press the Sweep from the bottom menu.
  • Page 241: Manage Arbitrary Waveforms

    ARBITRARY WAVE GENERATOR 6. Press More 1 of 2. 7. Press Span to set the frequency span of the sweep. 8. Press Center to set the center frequency for the configured span. 25Mhz ~ -25MHz Span Center 25MHz ~ 0.1Hz To configure a up sweeping, set the span with a Note positive frequency.
  • Page 242 MSO-2000E & 2000EA User Manual Example 1. Select an arbitrary waveform from the GEN1 Panel Operation Setup/GEN2 Setup menu: Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively. Press Waveform from the bottom menu. Select Arbitrary from the side menu.
  • Page 243: Edit An Existing Arb Waveform

    ARBITRARY WAVE GENERATOR 5. Press Function to choose an inbuilt waveform : Sine, Square, Pulse, Ramp, Function: Noise 6. Press OK Create to create the arbitrary waveform shape. Edit an Existing ARB Waveform Use the Edit Existing menu to edit a newly created Background waveform and further shape it according to your requirements.
  • Page 244 MSO-2000E & 2000EA User Manual Example This box shows the editing window in relation to the full ARB waveform Editing window Panel Operation 1. Select a waveform from the GEN1 Setup/GEN2 Setup menu: Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively.
  • Page 245 ARBITRARY WAVE GENERATOR 4. Press Normal Edit to insert a point Normal Edit or delete a point from the waveform: Insert Point: To insert a point, you must first set the position of the point to be inserted. a. Press Point to set the x-axis position of the point.
  • Page 246 MSO-2000E & 2000EA User Manual Exit Normal Edit 5. Press Go Back to exit the Normal Edit. 6. Press Function Edit to perform Function Edit more advanced editing functions. 7. Press Edit Method to choose the editing method: Point/Line Edit Method:...
  • Page 247 ARBITRARY WAVE GENERATOR c. The Adjustment soft-key can be used to toggle the step resolution of the variable knob when editing values in this menu. Fine, Coarse Adjustment d. Press Preview. The desired edit will then be previewed on the screen.
  • Page 248 MSO-2000E & 2000EA User Manual b. Press Point2/Level2 once to select the point’s X axis end point. Press Point2/Level2 again to select the amplitude (Level) of the end point. 1 ~ user-defined point position Point2 ±1.25Vdc (Load: 50Ω) Level2 ±2.5Vdc (Load: High Z) c.
  • Page 249 ARBITRARY WAVE GENERATOR 0.1x ~ 10X Scale b. Press Go Back to go back to the previous menu. Copy/Paste: a. Press Start to set the start point of the section you want to copy. b. Press Length to set the size of the section you want to copy from the start point.
  • Page 250: Load Arb Waveform

    MSO-2000E & 2000EA User Manual f. Press Go Back to go back to the previous menu. Clear Section: a. Press Start to set the start point of the section you want to clear. Press Length to set the size of the section you want to clear.
  • Page 251 ARBITRARY WAVE GENERATOR Press GEN1 Setup or GEN2 Setup for generator 1 or generator 2, respectively. Press Waveform from the bottom menu. Select Arbitrary from the side menu. 2. Press Waveform Edit from the bottom menu. 3. From the bottom menu select Load Waveform.
  • Page 252: Save Arb Waveform

    MSO-2000E & 2000EA User Manual Use the Variable knob to select the desired ARB waveform. Press the Select key to load the Select selected ARB waveform in the file utilities screen. File Utilities Press to manage the files on the internal Note disk or an inserted USB disk.
  • Page 253 ARBITRARY WAVE GENERATOR Arb1, Arb2, Arb3, Arb4 ARB: Press Save to save the waveform to the selected memory slot, Arb1, Abr2, Arb3 or Arb4. 5. Alternatively, to save to a USB drive or to the internal flash memory, press To File. 6.
  • Page 254: Coupling And Tracking Waveforms Settings

    MSO-2000E & 2000EA User Manual After Save Now has been pressed the file will be saved. The file will not be saved if the power Note is turned off or the USB drive is taken out before the message ends.
  • Page 255 ARBITRARY WAVE GENERATOR Tracking settings 3. From the side menu press Tracking to set the tracking mode to ON or OFF. ON, OFF Tracking: When Tracking is ON, all parameters set to one waveform will be copied to the other one and vice-versa.
  • Page 256 MSO-2000E & 2000EA User Manual 7. Use the Left and Right arrow keys to select a base unit and use the variable knob to increase or decrease the offset by that base unit, as shown in the Offset window. 8. Default can be pressed to set the Offset to 0.0Hz.
  • Page 257 ARBITRARY WAVE GENERATOR Frequency Coupling cannot be set if Tracking is ON. Note Configuring Frequency Coupling parameters will disable the Tracking mode. 15. Press Ampl Cpl to set Amplitude the amplitude coupling coupling to ON or OFF. OFF, ON Ampl Cpl: When set to ON, amplitude from both generated waveforms will be duplicated from one to the other one.
  • Page 258 MSO-2000E & 2000EA User Manual PPLICATIONS Introduction ........259 Overview ................259 Running Applications ............260 Go-NoGo application ......261 DVM application ........ 266 Data Log application ......268 Digital Filter application ....270 Mask application........ 272 Select the source channel ........... 272 Configure the mask violation ..........
  • Page 259: Applications

    Background software applications to be run. The MSO- 2000E/2000EA comes pre-installed with a number of apps, as described below. Please see your local GW Instek distributor for the latest information on new apps. The Go/No-Go application can be Included Go/No-Go...
  • Page 260: Running Applications

    MSO-2000E & 2000EA User Manual This app allows the scope to Mount Remote mount a network share drive. Disk The Demo app, when combined Demo with the GDB-03 demo board, allows the scope to trigger a number of different signals from the demo board.
  • Page 261: Go-Nogo Application

    APPLICATIONS Go-NoGo application The Go-NoGo test checks if a waveform fits inside Background a user-specified maximum and minimum boundary. Boundary templates are automatically created from a source channel. Boundary tolerances and violation conditions can be set. Choose the Go_NoGo application from the APP menu.
  • Page 262 MSO-2000E & 2000EA User Manual 2. Press Go Back to return to the previous menu. 3. Press Violating to set what action to Set Go-NoGo perform when a signal violates the Actions Go-NoGo conditions. The waveform stops when the conditions are violated.
  • Page 263 APPLICATIONS 8. To set the boundary tolerance as a Auto Tolerance percentage offset from the source waveform, press Auto Tolerance VARIABLE and use the Variable knob. 0.4% ~ 40% (.4% steps) Offset 9. To manually set the template Maximum and tolerance, press Minimum Position Minimum Position...
  • Page 264 MSO-2000E & 2000EA User Manual Start test Test stopped Stop test When Go-NoGo is running, the violation/test ratio Results is displayed in the bottom left-hand corner. The first digit represents the number of violations, and the right hand digit represents the number of tests.
  • Page 265 APPLICATIONS To output the Go-NoGo results to an Using the Go- external device, the Go-NoGo rear NoGo Output panel terminal (open collector) can be used. The Go-NoGo terminal will output a positive pulse each time a NoGo violation has occurred for a minimum of 500us.
  • Page 266: Dvm Application

    MSO-2000E & 2000EA User Manual DVM application The DVM app is a digital voltage meter or digital Background current meter readout that floats on the top left- hand side of the screen. However, please note that if the cursors (refer to page 65) are turned on, the DVM readout will be replaced by the cursor readout.
  • Page 267 APPLICATIONS Panel Operation Choose the DVM application from the APP menu. See page 260. 1. Press Source and select the source Set Source channel for the DVM. The probe type setting (voltage or current) determines whether the function acts as a digital voltmeter or as a digital current meter for the selected source.
  • Page 268: Data Log Application

    MSO-2000E & 2000EA User Manual Data Log application The Data Log app will log the current waveform Background data or screenshot at set intervals for a set duration of time. Basic Features: Log up to 100 hours of images or waveform ...
  • Page 269 APPLICATIONS 3. Press Source from the side menu and select a source channel to log if waveforms are to be logged. CH1 ~ CH4, D0~D15, All Displayed Source 4. Press Interval and set the logging interval time. Data: 2secs ~ 2mins Interval Image: 5secs ~ 2mins 5.
  • Page 270: Digital Filter Application

    MSO-2000E & 2000EA User Manual Digital Filter application The Digital Filter app is a digital high or low pass Background filter with a selectable cutoff frequency. The digital filter can be applied to analog channel individually or together using the tracking functionality. The Digital Filter is not applicable to the Digital channels.
  • Page 271 APPLICATIONS Panel Operation Choose the Digital filter application from the APP menu. See page 260. 1. Select a source channel by pressing Set Source CH1Filter, CH2 Filter, CH3 Filter or CH4 Filter. 2. From the side menu press Filtering and turn on. 3.
  • Page 272: Mask Application

    MSO-2000E & 2000EA User Manual Mask application The Mask application allows the user to create Background shape templates for easy comparison of an input signal with a defined shape. Panel Operation Choose the Mask application from the APP menu. See page 260.
  • Page 273: Configure The Mask Violation

    APPLICATIONS Configure the mask violation 1. Press the Violation button from the Step bottom menu. 2. Press the Stop button to stop the data acquisition and freeze the screen when the source waveform crosses the mask boundary (mask violation condition). Conversely, press the Continue button to continue acquiring data even when a mask violation condition is...
  • Page 274: Auto Mask

    MSO-2000E & 2000EA User Manual Auto Mask 1. Press the Auto Mask button from Step the bottom menu to create a mask shaped out from an existing waveform. 2. Press the Reference Source button from the side menu to select the pattern the mask will be shaped on.
  • Page 275 APPLICATIONS 6. Press the X Mask button from the side menu and use the Variable knob to adjust the horizontal deviation of the mask compared to its original pattern 7. Press the Y Mask button from the side menu and use the Variable knob to adjust the vertical deviation of the mask compared to its original pattern.
  • Page 276 MSO-2000E & 2000EA User Manual 9. Press the Create Mask button from the side menu. A mask is created (as shown in the below diagram) and can now be used. 10. Press the Auto Mask button from the bottom menu to close auto mask function.
  • Page 277: User Defined Mask / Create Mask

    APPLICATIONS User Defined Mask / Create Mask A user-defined mask can be created. Up to 8 areas Background of any form, each made of up to 10 points, can be built out and juxtaposed to each other to form the user-defined mask pattern.
  • Page 278 MSO-2000E & 2000EA User Manual 4. Press the Unit button from the side menu and use the Variable knob to either select Divisions (graticule division fractions) or Current (Actual oscilloscope X- and Y-axis scale units) as the points position units.
  • Page 279 APPLICATIONS 10. Repeat the above steps 6 to 9 to add other Edit the other points to the area and until you finalize the points shape of this first area. Then press the Go Back button to exit the Edit Points menu. Create other areas 11.
  • Page 280: User-Defined Mask File Format

    MSO-2000E & 2000EA User Manual 14. Press the Save button from the side Save the user- menu. defined mask 15. Use the variable knob and the select key to change the name of the file if needed and press the Save Now button from the side menu to save the user-defined mask.
  • Page 281 APPLICATIONS The user-defined mask files can be created out of Background support (from an external computer for example) and uploaded to the MSO-2000E/2000EA Mask application with a USB key device. Create an unformatted text file respecting the format described below.
  • Page 282: Save/Recall

    MSO-2000E & 2000EA User Manual AVE/RECALL File Format/Utility ......283 Image File Format ............... 283 Waveform File Format ............283 Spreadsheet File Format ............. 284 Setup File Format ..............286 Create/Edit Labels ......289 Save ........... 292 File Type/Source/Destination .......... 292 Save Image ................
  • Page 283: File Format/Utility

    SAVE/RECALL File Format/Utility Image File Format *.bmp or *.png Format Default Filename DSxxxx.bmp/png The display image is 800 by 480 pixels. The Contents background color can be inverted (Ink saver function). Each image file is saved to the current file path as a bitmap or PNG file. Waveform File Format DSxxxx.lsf, CH1~CH4.lsf Format...
  • Page 284: Spreadsheet File Format

    MSO-2000E & 2000EA User Manual Reference waveforms stored in the Ref 1~4 internal memory, separate from W1 ~ W20. Reference waveforms (Ref 1 ~ 4) can be displayed directly onto the display with amplitude and frequency information. Ref 1~4 are useful for reference purposes.
  • Page 285 SAVE/RECALL Analog channel signal Waveform Type CH1 ~ 4 Digital channel signal D0 ~ D15 Reference waveform Ref1~4 Math operation result (page 73) Math All the waveforms on the display. Displayed Detail CSV waveform data contains channel Contents: information such as vertical and horizontal Detail CSV position of a signal for all the recorded points.
  • Page 286: Setup File Format

    MSO-2000E & 2000EA User Manual Vertical units extend Label   Probe type Probe ratio   Vertical scale Vertical position   Horizontal units Horizontal scale   Horizontal position Horizontal mode   SincET mode Sampling period ...
  • Page 287 SAVE/RECALL Scale Expand Channel   Channel Position   Coupling Probe   Impedance Probe   attenuation Invert  Deskew  Bandwidth  Horizontal Vertical cursor Cursor   cursor V Unit  H Unit  Source Display Measure ...
  • Page 288 MSO-2000E & 2000EA User Manual Language Ink Saver Utility   Hardcopy key Assign Save   File Format Probe Comp.   Image file Data file format Save/   format recall 800.561.8187 information@itm.com www. .com...
  • Page 289: Create/Edit Labels

    SAVE/RECALL Create/Edit Labels Reference files, Setup files and the analog and Overview digital input channels can have individual file labels set. For the analog channels and reference waveforms, the file label can be displayed next to the channel/reference indicator. The file labels are also used to easily identify reference files, setup files or channels when saving or recalling waveforms and setups.
  • Page 290 MSO-2000E & 2000EA User Manual 3. Press Label For and select the item that you want to create the label for. CH1~CH4, Ref1~4, Set1~20, Math Label For Labels for digital channels can only be changed from Note the Logic Analyzer menu. See page 220.
  • Page 291 SAVE/RECALL VARIABLE Press Enter Character to select a number or letter. Press Back Space to delete a character. Press Save Now to save the label and return to the previous menu. To cancel the editing the label and return to the previous menu, press Cancel.
  • Page 292: Save

    MSO-2000E & 2000EA User Manual Save File Type/Source/Destination Item Source Destination Front panel Internal memory: Set1 ~ Panel Setup   settings Set20 (DSxxxx.set) File system: Disk, USB  Channel 1 ~ 4 Internal memory: Waveform Data   Reference waveform (DSxxxx.csv)
  • Page 293: Save Image

    SAVE/RECALL Save Image Images can be saved either using the Save/Recall key or by using the Hardcopy key. To save images using the Hardcopy key, see the hardcopy section on page 315. Panel Operation 1. To save to USB, connect a USB Front Panel drive to the front panel USB port.
  • Page 294 MSO-2000E & 2000EA User Manual 6. Press Save from the side menu to save the display as an image file. 7. You will automatically be taken to a file utility where you will be able to edit the name of the file.
  • Page 295: Save Waveform

    SAVE/RECALL To edit the internal memory or the File Utility USB flash drive contents (create/ delete/rename files and folders) or to edit the default file path, press File Utilities from the side menu. Save Waveform Panel Operation 1. To save to an external USB flash Front Panel drive, connect the drive to the front panel USB port.
  • Page 296 MSO-2000E & 2000EA User Manual 6. Press Save to save the file. 7. If you are saving to a file, a file utility appears where you will be able to edit the name of the file from the default “DSXXX” filename.
  • Page 297: Save Setup

    SAVE/RECALL To edit the internal memory or the File Utility USB flash drive contents (create/ delete/rename files and folders), press File Utilities. Save Setup Panel Operation 1. To saving to an external USB Front Panel flash drive connect the drive to the front or rear panel USB port.
  • Page 298 MSO-2000E & 2000EA User Manual 7. To edit the filename, use the Variable knob to highlight a character. VARIABLE Press Enter Character or the Select key to select a number or letter. Press Back Space to delete a character. 8. Press Save Now to save the file. The filename need not have been edited to save the file.
  • Page 299 SAVE/RECALL To edit labels for Setup files, press Edit Edit Label Label. For more details on editing labels, see page 289. 800.561.8187 information@itm.com www. .com...
  • Page 300: Recall

    MSO-2000E & 2000EA User Manual Recall File Type/Source/Destination Item Source Destination Factory installed Current front panel Default Panel   setting Setup Internal memory: Current front panel Reference   Ref1~4 Waveform Internal memory: S1 ~ Current front panel Panel Setup ...
  • Page 301: Recall Default Panel Setting

    SAVE/RECALL Recall Default Panel Setting Panel Operation 1. Press the Default key. Default 2. The screen will update with the default panel settings. Setting Contents The following is the default (factory) setting contents. Mode: Sample XY: OFF Acquire Record Length: 10k Expand: By Center Mode: Vector Persistence: 240ms...
  • Page 302 MSO-2000E & 2000EA User Manual Scale: 10us/Div Position: 0.000s Horizontal Source1: CH1 Operator: + Math Source2: CH2 Position: 0.00 Div Unit/Div: 200mV Math Off Source: CH1 Vertical Units: dBV RMS Window: Hanning Vertical: 20dB Horizontal:5MHz/div Expression: CH1+CH2 VAR1: 0 Advanced Math VAR2: 1 Position: 0.00Div...
  • Page 303: Recall Waveform

    SAVE/RECALL Recall Waveform Panel Operation 1. For recalling from an external Front Panel USB flash drive, connect the drive to the front or rear panel USB port. 2. The waveform must be stored in advance. See page 295 for waveform store details. 3.
  • Page 304: Recall Setup

    MSO-2000E & 2000EA User Manual Ref1~4 7. Press Recall Now to recall the waveform. The reference waveform will appear on the screen when successful. To edit USB flash drive contents File Utility (create/ delete/ rename files and folders) or to set the file path, press File Utilities.
  • Page 305 SAVE/RECALL 4. Press From (internal memory) or From File and choose a source to recall from. Set1~20 From From File DSxxxx.set (USB, Disk)* * Only files in the current file path will be available. 5. Press Recall Now to confirm recalling.
  • Page 306: Reference Waveforms

    MSO-2000E & 2000EA User Manual Reference Waveforms Recall and Display Reference Waveforms Panel Operation A reference waveform must be stored in advance. See page 295 to store waveforms as reference waveforms. 1. Press the REF key on the front panel.
  • Page 307 SAVE/RECALL Press Vertical repeatedly from the side Vertical menu to choose to edit the vertical Navigation position or Unit/Div. Use the Variable knob to edit the values. Press Horizontal repeatedly from the Horizontal side menu to choose to edit the Navigation Time/Div or the horizontal position.
  • Page 308: File Utilities

    MSO-2000E & 2000EA User Manual ILE UTILITIES The file utilities are used each time files need to be saved to internal or external memory. The file utilities can create, delete and rename directories or files as well as copy files from internal memory to USB.
  • Page 309: File Navigation

    FILE UTILITIES File Navigation The File Utilities menu can be used to choose files or to set the file path for saving/recalling files. File System File path Drive space File cursor File attributes Panel Operation 1. Press the Utility key. Utility 2.
  • Page 310 MSO-2000E & 2000EA User Manual 4. Use the Variable knob to move the VARIABLE file cursor up and down. Use the Select key to choose a file or directory or to set the file path. Select When a USB flash drive is used, the file path is...
  • Page 311: Create Folder

    FILE UTILITIES Create Folder Panel Operation 1. Press the Utility key. Utility 2. Press File Utilities from the bottom menu. 3. Use the Variable knob and Select key to navigate the file system. 4. Press Create Folder to make a new Create Folder directory at the selected location.
  • Page 312: Rename File

    MSO-2000E & 2000EA User Manual Press Cancel to cancel the operation. Cancel Rename File Panel Operation 1. Press the Utility key. Utility Press File Utilities from the bottom menu. Use the Variable knob and select key to choose a file to rename.
  • Page 313: Delete File Or Folder

    FILE UTILITIES Press Save Now to rename the folder or file. Delete File or Folder Panel Operation 1. Press the Utility key. Utility Press File Utilities from the bottom menu. Use the Variable knob and select key to navigate the file system to choose a file.
  • Page 314: Copy File To Usb

    MSO-2000E & 2000EA User Manual Copy File to USB Panel Operation 1. Connect a USB drive to the Front Panel front panel USB port. Press the Utility key. Utility Press File Utilities from the bottom menu. Use the Variable knob and Select key to navigate the file system to choose a file from internal memory.
  • Page 315: Hardcopy Key

    HARDCOPY KEY ARDCOPY KEY The Hardcopy key is used as quick-save or quick-print key. The Hardcopy key can be assigned either to printout screenshots or to save files. When assigned to “Print” the screen image can be printed to a PictBridge compatible printer using the USB device port.
  • Page 316 MSO-2000E & 2000EA User Manual Print Output Ensure the USB port has been configured for the printer and the printer is connected to the scope before trying to print, see page 315. Panel Operation 1. Press the Utility key. Utility 2.
  • Page 317 HARDCOPY KEY Save - Hardcopy Key When the Hardcopy key is assigned to “Save”, Background pressing the Hardcopy key can be used to save a screen shot, a waveform, or the current setup, depending on the configuration. Panel Operation 1. If you wish to save to USB, Front connect a USB drive to the front panel USB port, otherwise the...
  • Page 318 MSO-2000E & 2000EA User Manual 7. For image files the file format can Image File be selected with the File Format Format key. BMP, PNG Format: 8. To have a white background for Ink Saver image files, set Ink Saver to On.
  • Page 319: Remote Control Config

    CONFIG This chapter describes basic configuration for remote control. For a complete command list, refer to the programming manual downloadable from GW Instek website, www.gwinstek.com. Interface Configuration ...... 320 Configure USB Interface............ 320 USB Functionality Check ........... 321 Configure the Ethernet Interface ........322 Configure Socket Server .............
  • Page 320: Interface Configuration

    USB driver included on the accompanying User Manual CD or download the driver from the GW Instek website, www.gwinstek.com, in the MSO-2000E Download section. The driver automatically sets the MSO-2000E/2000EA as a serial COM port (Shown as VPO in the PORTS node). 800.561.8187 information@itm.com...
  • Page 321: Usb Functionality Check

    This should return the Manufacturer, Model number, Serial number, and Firmware version in the following format. GW,MSO-2xxxE,PXXXXXX,V1.00 For further details about remote control and remote Note commands, please see the programming manual, available on the GW Instek website. 800.561.8187 information@itm.com www. .com...
  • Page 322: Configure The Ethernet Interface

    MSO-2000E & 2000EA User Manual Configure the Ethernet Interface Ethernet MAC Address Domain Name Configuration Instrument Name DNS IP Address User Password Gateway IP Address Instrument IP Subnet Mask Address HTTP Port 80 (fixed) The Ethernet interface is used for remote control Background using a socket server connection.
  • Page 323 REMOTE CONTROL CONFIG 6. Use the Up and Down arrows on the side menu to navigate to each Ethernet configuration item. MAC Address, Instrument Name, Items User Password, Instrument IP Address, Domain Name, DNS IP Address, Gateway IP Address, Subnet Mask Note: HTTP Port is fixed at 80.
  • Page 324: Configure Socket Server

    Complete will be displayed when successful. Configure Socket Server The MSO-2000E/2000EA supports socket server functionality for direct two-way communication with a client PC or device over LAN. By default, the Socket Server is off. 1. Configure the IP address for the...
  • Page 325: Socket Server Functionality Check

    Explorer can be used. This program is available on the NI website, www.ni.com. 1. Configure the IP address for the Page 322 Operation MSO-2000E/2000EA. 2. Configure the socket port. Page 324 3. Start the NI Measurement and Automation Explorer (MAX) program.
  • Page 326 New Visa TCP/IP Resource… 6. Select Manual Entry of Raw Socket from the popup window. 7. Click Next. 8. Enter the MSO-2000E/2000EA’s IP address and socket port number. 9. Click Validate. 10. A popup will appear to tell you if a VISA socket 800.561.8187...
  • Page 327 11. Click Next. 12. Choose an alias for the socket connection if you like. 13. Click Finish to finish the configuration. 14. The MSO-2000E/2000EA will now appear under Network Devices in the Configuration Panel. 800.561.8187 information@itm.com www.
  • Page 328 MSO-2000E & 2000EA User Manual 15. Click the Open Visa Test Panel to send a remote Functionality command to the MSO-2000E/2000EA. Check 16. Click on the Configuration icon. 17. Select the I/O Settings tab. 18. Mark the Enable Termination Character checkbox.
  • Page 329 REMOTE CONTROL CONFIG 20. Click the Input/Output icon. 21. Make sure the *IDN? query is selected in the Select or Enter Command drop box. 22. Click on Query. 23. The manufacturer, model number, serial number and firmware version will be displayed in the buffer.
  • Page 330 MSO-2000E & 2000EA User Manual AINTENANCE Three types of maintenance operations are available: Signal Path Compensation, Vertical Accuracy Calibration and Probe Compensation. Run these operations when using the MSO- 2000E/2000EA in a new environment. How to use the SPC function ........... 331 Vertical Accuracy Calibration ..........
  • Page 331: Maintenance

    MAINTENANCE How to use the SPC function Signal Path Compensation (SPC) is used to Background compensate the internal signal path due to ambient temperature. SPC is able to optimize the accuracy of the oscilloscope with respect to the ambient temperature. Panel Operation 1.
  • Page 332 MSO-2000E & 2000EA User Manual Vertical Accuracy Calibration Panel Operation 1. Press the Utility key. Utility 2. Press System from the bottom menu. 3. Press more 1 of 3 from the side menu. 4. Press Self Cal on the side menu.
  • Page 333 MAINTENANCE 8. Press Vertical again after connecting CAL to the channel 1 input. The calibration for Channel 1 starts and ends automatically, in less than 5 minutes. A message is displayed when the calibration procedure has ended. 9. Repeat the above step for Channel 2, 3* and 4* when prompted.
  • Page 334 MSO-2000E & 2000EA User Manual VARIABLE HORIZONTAL SCALE POSITION PUSH TO ZERO VERTICAL TRIGGER POSITION POSITION LEVEL POSITION POSITION MATH PUSH TO PUSH TO PUSH TO PUSH TO PUSH TO ZERO ZERO ZERO ZERO ZERO SCALE SCALE SCALE SCALE POWER 16pF 300Vrms MAX.
  • Page 335 MAINTENANCE 8. Turn the adjustment point on the probe to make the waveform as square as possible. Under Over Normal Compensation Compensation 800.561.8187 information@itm.com www. .com...
  • Page 336: Faq

    MSO-2000E & 2000EA User Manual • I connected the signal but it does not appear on the display. • I want to remove the (Measurement result / FFT result / Help contents) from the display. • The waveform does not update (frozen).
  • Page 337 The date and time settings are not correct. For date and time setting details, please see page 204. If it does not help, the internal battery controlling the clock might be worn out. Contact your dealer or GW Instek. 800.561.8187 information@itm.com www.
  • Page 338 Make sure the device is powered On for at least 30 minutes, within +20°C~+30°C. This is necessary to stabilize the unit to match the specification. For more information, contact your local dealer or GW Instek at www.gwinstek.com / marketing@goodwill.com.tw. 800.561.8187 information@itm.com...
  • Page 339: Appendix

    APPENDIX PPENDIX Updating the Firmware ...... 340 MSO-2000E/2000EA Specifications ..342 Model-specific ..............342 Common ................343 Probe Specifications ......347 Dimensions ........349 Declaration of Conformity ....350 800.561.8187 information@itm.com www. .com...
  • Page 340: Updating The Firmware

    MSO-2000E & 2000EA User Manual Updating the Firmware New firmware can be downloaded from the GW Background Instek website in the MSO products section. Place a copy of the firmware onto the root directory of a USB memory stick. Panel Operation 1. Put the USB drive that contains...
  • Page 341 APPENDIX Press the Select key again to Select confirm the installation of the firmware. Alternatively, press any other key to cancel the installation. 7. Wait for the installation process to complete. When the installation has completed you will be prompted to restart the oscilloscope. Remove the USB drive and proceed to the restart.
  • Page 342: Mso-2000E/2000Ea Specifications

    MSO-2000E & 2000EA User Manual MSO-2000E/2000EA Specifications The specifications apply when the MSO-2000E/2000EA is powered on for at least 30 minutes under +20°C~+30°C. Model-specific MSO-2072E / 2072EA Channels 2 + Ext Bandwidth DC ~ 70MHz (–3dB) Rise Time Bandwidth Limit...
  • Page 343: Common

    APPENDIX Common Vertical Resolution 8 bit Sensitivity :1mV*~10V/div *: When the vertical scale is set to 1mV/div, the bandwidth limit will be set to 20MHz automatically. Input Coupling AC, DC, GND Input Impedance 1MΩ// 16pF approx. DC Gain Accuracy* 1mV: ±5% full scale ≥2mV: ±3% full scale Polarity Normal &...
  • Page 344 MSO-2000E & 2000EA User Manual Post-trigger 2,000,000 div maximum. ±50 ppm over any ≥ 1 ms time interval Timebase Accuracy Real Time Sample Rate 1GSa/s max. (4ch models); 1GSa/s per channel (2ch models) Record Length Max. 10Mpts Acquisition Mode Normal, Average, Peak Detect, Single...
  • Page 345 APPENDIX Output Accuracy 2% (1 kHz) Offset Range ±2.5 V, HighZ Sine: Frequency Range 100 mHz to 25 MHz Flatness ±0.5 dB (relative to 1 kHz) Harmonic Distortion -40 dBc Stray (Non-harmonic) -40 dBc Total Harmonic Distortion S/N Ratio 40 dB Square/Pulse: Frequency Range Square: 100 mHz to 15 MHz...
  • Page 346 MSO-2000E & 2000EA User Manual Waveform Update Rate 120,000 waveforms per second, maximum Display Graticule 8 x 10 divisions Display Mode YT, XY Interface USB Port USB 2.0 High-speed host port X1, USB High-speed 2.0 device port X1 Ethernet Port (LAN)
  • Page 347: Probe Specifications

    APPENDIX Probe Specifications GTP-070B-4 Applicable to: MSO-2072E/2072EA & MSO-2074E/2074EA Position x10 Attenuation Ratio 10:1 Bandwidth DC to 70MHz Input Resistance 10MΩ when used with oscilloscopes with 1MΩ input Input Capacitance 14.5pF to 17.5pF Compensation Range 10pF to 35pF ≤600V DC + ACpk Max.
  • Page 348 MSO-2000E & 2000EA User Manual GTP-200B-4 Applicable to: MSO-2202E/2202EA & MSO-2204E/2204EA Position X10 Attenuation Ratio 10:1 Bandwidth DC to 200MHz Input Resistance 10MΩ when used with oscilloscopes with 1MΩ input. Input Capacitance 10.5pF to 17.5pF Compensation Range 5pF to 30pF ≤600V DC + ACpk...
  • Page 349: Dimensions

    APPENDIX Dimensions VARIABLE Measure Cursor Acquire Autoset Display Help Save/Recall Utility Run/Stop HORIZONTAL SCALE Single POSITION Search Zoom Select Default Set/Clear PUSH TO ZERO VERTICAL TRIGGER POSITION POSITION LEVEL MATH PUSH TO PUSH TO PUSH TO ZERO ZERO ZERO Menu 50 % SCALE SCALE...
  • Page 350: Declaration Of Conformity

    MSO-2000E & 2000EA User Manual Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. declare that the below mentioned product Type of Product: Mixed-signal oscilloscope Model Number: MSO-2072E, MSO-2072EA, MSO-2074E, MSO-2074EA, MSO-2102E, MSO-2102EA, MSO-2104E, MSO-2104EA, MSO-2202E, MSO-2202EA, MSO-2204E, MSO-2204EA are herewith confirmed to comply with the requirements set out in the...
  • Page 351: Index

    INDEX NDEX AC coupling ......117 AC Priority mode ...... 45 AM ..........233 channel activation ...... 227 Acquisition ......... 86 connection ........226 average ...........86 Coupling and tracking ....254 indicator .........29 Create new ARB waveform ..241 peak detect ........86 edit existing waveform ....
  • Page 352 MSO-2000E & 2000EA User Manual Parallel ........187 pollution degree ......9 SPI ........... 181 Erase memory ......203 UART ........176 Ethernet UART ........... 128 interface........322 Channel ........43 Expand by ground/center ..120 status indicator ......30 External trigger ......
  • Page 353 INDEX Invert waveform ...... 118 Pulse width trigger ....166 Keys overview ......19 QR code reader function ..205 Labels ........289 Rear panel diagram ... 26, 225 Language selection ....202 Recall ......... 300 default setup ....... 301 List of features ......
  • Page 354 MSO-2000E & 2000EA User Manual configuration ........ 94 indicator ........29 infomation ........102 logic ..........188 measurement ........ 98 mode ..........162 navigation ........97 parameters ........154 overview ........91 pulse runt ........170 play back ........97 pulse width .........

This manual is also suitable for:

Mso-2000ea

Table of Contents