Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
GW Instek Manuals
Test Equipment
MDO-2202A
User manual
GW Instek MDO-2202A User Manual
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
page
of
339
Go
/
339
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Safety Instructions
Safety Guidelines
Power Cord for the United Kingdom
Getting Started
MDO-2000A Series Overview
Integrated Instruments and Series Lineup
Main Features
Accessories
Appearance
Front Panel
User Interface
Rear Panel
MDO-2000A Series
MDO-2000AG Series
Display
Set up
Tilt Stand
Power up
First Time Use
How to Use this Manual
Built-In Help
Measurement
Basic Measurement
Channel Activation
Autoset
Run/Stop
Horizontal Position/Scale
Vertical Position/Scale
Automatic Measurement
Measurement Items
Add Measurement
Remove Measurement
Gated Mode
Display All Mode
High Low Function
Statistics
Reference Levels
Cursor Measurement
Use Horizontal Cursors
Use Vertical Cursors
Math Operation
Basic Math Overview & Operators
Addition/Subtraction/Multiplication/Division
FFT Overview & Window Functions
FFT Operation
Advanced Math Overview
Advanced Math Operation
Advanced Configuration
Acquisition
Select Acquisition Mode
Show Waveform in XY Mode
Set the Record Length
Segmented Memory Acquisition
Segments Display
Set the Number of Segments
Run Segmented Memory
Navigate Segmented Memory
Play through each Segment
Measurement on Segments
Segment Info
Display
Display Waveform as Dots or Vectors
Set the Level of Persistence
Set the Intensity Level
Select Display Graticule
Freeze the Waveform (Run/Stop)
Turn off Menu
Horizontal View
Move Waveform Position Horizontally
Select Horizontal Scale
Select Waveform Update Mode
Zoom Waveform Horizontally
Play/Pause
Vertical View (Channel)
Move Waveform Position Vertically
Select Vertical Scale
Select Coupling Mode
Input Impedance
Invert Waveform Vertically
Limit Bandwidth
Expand by Ground/Center
Select Probe Type
Select Probe Attenuation Level
Set the Deskew
Bus Key Configuration
Bus Display
Serial Bus Overview
UART Serial Bus Configuration
I 2 C Serial Bus Interface
CAN Serial Bus Interface
LIN Serial Bus Interface
Bus Encoding
Threshold Configuration
Serial Bus Event Tables
Event Tables Format
Adding a Label to a Bus
Using Cursors with the Serial Bus
Trigger
Trigger Type Overview
Trigger: Types and Sources
Trigger Parameter Overview
Setup Holdoff Level
Setup Trigger Mode
Using the Edge Trigger
Using Advanced Delay Trigger
Using Pulse Width Trigger
Using Video Trigger
Pulse Runt Trigger
Using Rise and Fall Trigger
Using the Timeout Trigger
Using the Bus Trigger
UART BUS Trigger Settings
I 2 C Bus Trigger Settings
CAN Bus Trigger
LIN Bus Trigger
Search
Configuring Search Events
Copying Search Event To/From Trigger Events
Search Event Navigation
Save Search Marks
Setting/Clearing Single Search Events
FFT Peak
System Settings and Miscellaneous Settings
Select Menu Language
View System Information
Erase Memory
Set Date and Time
Probe Compensation Frequency
QR Code Reader Function
Arbitrary Wave Generator
Arbitrary Wave Generator Operation
Overview
Rear Panel
AWG Display Overview
Generator Connection
Output Setup
Select the Active Channel
Turn the Output on for the Selected Channel
Setting the Load Impedance
Setting the Phase
GEN1 and GEN2 Setup
Selecting a Waveform
Waveform Settings
AM Modulation
FM Modulation
FSK Modulation
Sweep
Manage Arbitrary Waveforms
Create New ARB Waveform
Edit an Existing ARB Waveform
Load ARB Waveform
Save ARB Waveform
Coupling and Tracking Waveforms Settings
Spectrum Analyzer
Spectrum Analyzer Operation
Overview
Display Overview
Connections
Configuration
Selecting the Source
Setting the Trace Mode Options (Trace Type)
Setting the Detection Method
Configuring the Frequencies and Span
Configuring the Bandwidth
Configuring the Amplitude
Measurement
Using the Search Function
Using the Cursors
Applications
Introduction
Overview
Running Applications
Go-Nogo Application
DVM Application
Data Log Application
Digital Filter Application
Mask Application
Select the Source Channel
Configure the Mask Violation
Auto Mask
User Defined Mask / Create Mask
User-Defined Mask File Format
FRA Application
Display Overview
Connections
Launching the FRA Application
Setting Mode
FRA Run
Source
Setup Amplitude Profile and Edit Profile
Setup AWG
Reference Circuit
Quit
Analysis Mode
FRA Measure
Scale Bode Plot
FRA Utility
Save/Recall
File Format/Utility
Image File Format
Waveform File Format
Spreadsheet File Format
Setup File Format
Create/Edit Labels
Save
File Type/Source/Destination
Save Image
Save Waveform
Save Setup
Recall
File Type/Source/Destination
Recall Default Panel Setting
Recall Waveform
Recall Setup
Reference Waveforms
Recall and Display Reference Waveforms
File Utilities
File Navigation
Create Folder
Rename File
Delete File or Folder
Copy File to USB
Hardcopy Key
Remote Control Config
Interface Configuration
Configure USB Interface
USB Functionality Check
Configure the Ethernet Interface
Configure Socket Server
Socket Server Functionality Check
Maintenance
Probe Compensation
Faq
Appendix
Updating the Firmware
MDO-2000A Series Specifications
Model-Specific
Common
Probe Specifications
Gtp-100B-4
Gtp-200B-4
Gtp-300B-4
Dimensions
Declaration of Conformity
Index
Advertisement
Quick Links
Download this manual
Mixed-Domain Oscilloscope
MDO-2000A Series
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Chapters
Table of Contents
3
Etting Started
10
Easurement
35
Dvanced Configuration
74
Rbitrary Wave Generator
178
Pectrum Analyzer
212
Pplications
230
Ave/Recall
270
Ile Utilities
295
Emote Control Config
305
Table of Contents
Need help?
Do you have a question about the MDO-2202A and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for GW Instek MDO-2202A
Test Equipment GW Instek MDO-2000A Series User Manual
(339 pages)
Test Equipment GW Instek MDO-2102A User Manual
(339 pages)
Test Equipment GW Instek MDO-2000EG User Manual
Mixed-domain oscilloscope (351 pages)
Test Equipment GW Instek MDO-2000E Series User Manual
Mixed-domain oscilloscope (377 pages)
Test Equipment GW Instek MDO-2000E Series Programming Manual
Mixed-domain oscilloscope (322 pages)
Test Equipment GW Instek MSO-2000EA User Manual
Mixed-signal oscilloscope (351 pages)
Test Equipment GW Instek MSO-2000E User Manual
Mixed-signal oscilloscope (354 pages)
Test Equipment GW Instek MPO-2000 Series MPO-2000B User Manual
Multi-function programmable oscilloscope (393 pages)
Test Equipment GW Instek MPO-2204P User Manual
Multi-function programmable oscilloscope (393 pages)
Test Equipment GW Instek GDS-2072A User Manual
Digital storage oscilloscope gds-2000a series (261 pages)
Test Equipment GW Instek GDS-2000A Series User Manual
Digital storage oscilliscope (261 pages)
Test Equipment GW Instek GDS-820 Programming Manual
Digital storage oscilloscope (90 pages)
Test Equipment GW Instek GDS-800 Series Operation Manual
Digital storage oscilloscope (82 pages)
Test Equipment GW Instek GDS-1000A Series User Manual
Digital storage oscilloscope (67 pages)
Test Equipment GW Instek GOS-630FC User Manual
Dual trace oscilloscope (20 pages)
Test Equipment GW Instek GPT-9900 Series User Manual
Electrical safety tester (182 pages)
Summarization of Contents
USER MANUAL
Mixed-Domain Oscilloscope
Introduces the MDO-2000A Series user manual.
ISO-9001 Certified Manufacturer
Indicates the manufacturer is certified under ISO-9001.
Table of Contents
SAFETY INSTRUCTIONS
Provides essential safety guidelines for instrument operation.
GETTING STARTED
Covers initial setup and basic operation of the MDO-2000A Series.
MEASUREMENT
Details various measurement functions and techniques available on the oscilloscope.
ADVANCED CONFIGURATION
Explores advanced settings for acquisition, display, and signal analysis.
ARBITRARY WAVE GENERATOR
Describes the operation and features of the built-in arbitrary waveform generator.
SPECTRUM ANALYZER
Explains how to use the spectrum analyzer function for frequency domain analysis.
APPLICATIONS
Covers various software applications like DVM, Data Log, and FRA.
SAVE/RECALL
Details procedures for saving and recalling instrument settings and data.
FILE UTILITIES
Manages files, folders, and USB storage for the instrument.
HARDCOPY KEY
Explains the functionality of the hardcopy key for printing or saving.
REMOTE CONTROL CONFIG
Covers configuration for remote control via USB and Ethernet interfaces.
MAINTENANCE
Outlines maintenance procedures like calibration and compensation.
FAQ
Provides answers to frequently asked questions about the instrument.
APPENDIX
Contains supplementary information such as firmware updates and specifications.
SAFETY INSTRUCTIONS
Safety Symbols
Explains the meaning of various safety symbols used in the manual.
General Safety Guidelines
Lists general safety precautions for operating the MDO-2000A series.
Power Supply Safety
Details power supply requirements and safety precautions.
Cleaning and Operation Environment
Provides cleaning instructions and specifies operating conditions for the instrument.
GETTING STARTED
MDO-2000A Series Overview
Provides an overview of the MDO-2000A series instruments and lineup.
Appearance and Panel Layout
Describes the physical appearance and layout of the oscilloscope's front and rear panels.
Initial Setup Procedures
Guides the user through the initial setup procedures for the device.
Built-in Help System
Explains how to access and use the oscilloscope's on-screen help system.
Appearance and Front Panel Controls
Menu Keys and Navigation
Explains the usage of side and bottom menu keys for navigation and selection.
Hardcopy and Function Keys
Details the function of the Hardcopy key and various function keys for accessing features.
Variable Knob and Select Key Operation
Describes how to use the Variable knob and Select key for parameter adjustment and selection.
Autoset Function
Describes the Autoset function for automatic configuration of display parameters.
Basic Operations and Controls
Run/Stop and Single Trigger Modes
Explains how to freeze waveforms using the Run/Stop key or Single Trigger mode.
Default Setup and Horizontal Controls
Resets the system to defaults and details horizontal controls for waveform viewing.
Oscilloscope Features Overview
Search and Trigger Controls
Covers controls for trigger setup and using the search function for events.
Vertical Position and Channel Controls
Describes adjusting vertical position and using channel menu keys.
Interface Elements and Connections
External Trigger, Math, Reference, and Bus Keys
Explains functions of external trigger, math, reference, and bus keys.
Channel Inputs and USB Host Port
Details channel input specifications and the USB host port for data transfer.
Rear Panel Ports and Display Overview
Rear Panel Connectors
Shows the layout and ports on the rear panel of the MDO-2000A and MDO-2000AG series.
Calibration Output
Details the calibration output signal and its purpose.
Interface Ports and Outputs
Describes USB, LAN, Security Slot, Go-No Go, and AWG outputs.
Main Display Description
Provides a general description of the main display and its functions.
Waveform Display Elements
Waveform Status Indicators
Shows indicators for channel, horizontal, trigger status, position, level, frequency, and memory bar.
Waveform Data Display
Displays analog waveforms, bus decoding, reference waveforms, and channel indicators.
Instrument Status and Configuration
Trigger Status and Acquisition Modes
Describes trigger status indicators and acquisition modes: Normal, Peak Detect, Average.
Signal Frequency and Trigger Configuration
Shows signal frequency, trigger configuration, horizontal status, and channel status.
Initial Device Setup
Tilt Stand and Power Up
Explains adjusting the tilt stand and powering on the oscilloscope.
First Time Use Guide
Provides a step-by-step guide for setting up the instrument for initial operation.
Basic Waveform Operations
Signal Capture and Display Modes
Describes using Autoset for signal capture and selecting Vector display mode.
Probe Compensation Procedure
Guides on adjusting the probe for optimal signal display.
Manual Usage Conventions
Provides guidance on understanding the manual's conventions and structure.
Navigating the User Interface
Menu Item and Parameter Selection
Explains how to select menu items, parameters, or variables using the controls.
Menu Navigation Examples
Toggling Parameters and Reducing Menus
Explains how to toggle parameters and reduce side menus.
Reducing Lower Menus and Removing All Menus
Explains how to reduce lower menus and remove all displayed menus.
Removing On-Screen Messages
Explains how to use the Menu Off key to clear on-screen messages.
Built-in Help System Guide
Accessing and Operating Help
Guides on accessing and using the instrument's built-in help system and panel operations.
Help Menu Navigation Keys
Explains the function of Home, Go Back, and Exit keys within the help menu.
MEASUREMENT FUNCTIONS
Basic Measurement Operations
Covers fundamental operations for capturing and viewing input signals.
Channel Activation and Deactivation
Guides on activating and deactivating input channels for measurement.
Automatic Measurement Features
Details how to perform and manage automatic measurements and their items.
Cursor Measurement Techniques
Explains how to use horizontal and vertical cursors for waveform analysis.
Math Operation Functions
Covers performing basic math functions like addition, subtraction, multiplication, and division.
Waveform Measurement Details
Amplitude, High, Low, and Mean Measurements
Describes measurements for amplitude, high/low voltage, and mean values.
Cycle, RMS, Area, and Overshoot Measurements
Explains cycle mean, RMS, area, and overshoot measurements.
Time and Delay Measurement Types
Covers measurements related to time, such as frequency, period, and delay.
Pulse, Flicker, and Edge Measurements
Describes measurements for pulses, flicker, and edges.
Measurement Configuration and Management
Adding and Removing Measurements
Guides on adding multiple automatic measurements and removing them.
Gated Measurement Modes
Explains limiting automatic measurements to a specific area using cursors.
Display All Mode and Delay Measurements
Shows all measurements and notes delay measurements' availability.
High-Low Functionality
Explains how to select methods for determining High-Low measurement values.
Statistics and Reference Levels
Explains viewing statistics for measurements and setting reference levels.
Cursor Measurement and Usage
Horizontal Cursor Operations
Guides on activating and using horizontal cursors for measurements.
Vertical Cursor Operations
Guides on activating and using vertical cursors for measurements.
FFT and XY Mode Cursors
Details FFT and XY mode cursors and their measurement capabilities.
Math and FFT Operations
Basic Math Operations
Covers performing basic math functions like addition, subtraction, multiplication, and division.
FFT Overview and Window Functions
Explains the Fast Fourier Transform and available window functions.
FFT Operation Procedures
Guides on performing Fast Fourier Transform analysis.
Advanced Math Overview
Introduces advanced math functions and their parameters.
Advanced Math Operation Steps
Details how to create and perform advanced mathematical expressions.
ADVANCED CONFIGURATION OPTIONS
Acquisition Settings
Explains the process of sampling analog input signals into digital format.
Segmented Memory Acquisition
Details the utility for dividing scope memory into segments for optimized acquisition.
Display Settings
Covers display settings like waveform appearance, persistence, and intensity.
Horizontal View Controls
Covers setting horizontal scale, position, and waveform display mode.
Vertical View and Channel Settings
Explains how to set vertical scale, position, and coupling mode for channels.
Bandwidth and Expansion Settings
Details bandwidth limitation and signal expansion relative to ground or center.
Probe Configuration and Deskew
Guides on setting probe type, attenuation, and deskew compensation.
Bus Configuration and Triggering
Covers configuration for serial bus inputs, display, and triggering.
Trigger Setup and Parameters
Explains trigger types, sources, parameters, and modes for waveform capture.
Search Functionality
Describes using the search feature to find events in analog and digital channels.
System Settings and Maintenance
Menu Language and System Information
Guides on selecting menu language and viewing system information.
Memory Management
Details the process of erasing internal waveforms, setup files, and labels.
Date, Time, and Probe Compensation Setup
Guides on setting date/time and probe compensation frequency.
QR Code Reader Function
Describes the QR code reader function for accessing websites.
ARBITRARY WAVE GENERATOR OPERATION
AWG Overview and Connections
Introduces the AWG and details rear panel layout and generator connections.
Output Setup and Channel Selection
Covers selecting channels, turning output on/off, load impedance, and phase.
GEN1 and GEN2 Setup Procedures
Covers selecting waveform, settings, and creating arbitrary waveforms.
Waveform Settings: Frequency, Amplitude, Offset
Details setting frequency, amplitude, and offset for selected waveforms.
Modulation Functions: AM, FM, FSK
Explains Amplitude, Frequency, and Frequency Shift Keying Modulation settings.
Sweep Functionality
Covers sweep function for linear or logarithmic sweeping.
Managing Arbitrary Waveforms
Details creating, editing, recalling, and saving arbitrary waveforms.
Waveform Editing Methods
Explains Normal Edit and Function Edit methods for modifying waveforms.
Loading Arbitrary Waveforms
Guides on loading ARB waveforms from internal memory or USB.
Saving Arbitrary Waveforms
Details saving ARB waveforms to internal memory or USB.
Waveform Coupling and Tracking
Explains coupling and tracking waveform settings between GEN1 and GEN2.
SPECTRUM ANALYZER OPERATIONS
Spectrum Analyzer Overview
Introduces the Spectrum Analyzer as a real-time tool for frequency domain analysis.
Display Overview and Information
Explains the main display and its components for spectrum analysis.
Connections and Configuration
Details connecting signal sources and configuring spectrum traces.
Trace Mode Options
Details trace options like Normal, Max/Min Hold, and Average.
Detection Method Settings
Explains selecting detection methods (Sample, Peak, Average) for trace data.
Frequency, Span, and Bandwidth Configuration
Guides on setting center frequency, span, and bandwidth for analysis.
Amplitude Configuration
Explains how to configure vertical scale and zero reference position.
Spectrum Analyzer Measurement Tools
Covers measurement tools like search and cursors for frequency domain analysis.
APPLICATIONS
Introduction to Applications
Introduces the Application (APP) function and available software applications.
Running Applications Guide
Guides on activating pre-installed applications from a dedicated menu.
Go-NoGo Application
Explains the Go-NoGo test for checking waveform compliance with boundaries.
DVM Application
Details the Digital Voltmeter application for measuring voltage and current.
Data Log Application
Explains the Data Log app for logging waveform data or screenshots.
Digital Filter Application
Describes the Digital Filter app for applying high, low, or band pass filters.
Mask Application Features
Explains creating shape templates for comparing input signals.
FRA Application Overview
Details the Frequency Response Analyzer application for plotting gain and phase responses.
Mask Application Setup
Source Channel Selection
Guides on selecting the source channel for mask comparison.
Mask Violation Configuration
Details setting mask violation conditions (Stop, Continue, Save).
Auto Mask Creation
Guides on creating a mask shape from an existing waveform.
User Defined Mask Creation
Guides on creating user-defined masks with multiple areas and points.
SAVE/RECALL FUNCTIONS
File Format and Utility Options
Covers image, waveform, and spreadsheet file formats and utilities.
Waveform File Formats
Details LSF and CSV file formats for storing and recalling waveforms.
Setup File Format and Contents
Describes proprietary setup file format and its saved settings.
Save and Recall Operations
Covers creating/editing file labels for channels, reference files, and setups.
Save File Procedures
Details saving panel setup, waveform data, and display images.
Save Image Functionality
Explains saving display images using Save/Recall or Hardcopy keys.
Save Waveform Procedures
Guides on saving waveforms to internal memory or USB flash drive.
Save Setup Procedures
Details saving instrument setup configurations to internal memory or USB.
Recall Operations
Covers recalling default panel settings, reference waveforms, and setups.
Recall Waveform Functionality
Guides on recalling stored waveforms from internal memory or USB.
Recall Setup Functionality
Explains how to recall saved instrument setup configurations.
Reference Waveforms Display
Explains how to recall and display stored reference waveforms.
FILE UTILITIES MANAGEMENT
File Utilities Overview
Describes file utilities for managing files and folders on internal or external memory.
File Navigation and Path Settings
Guides on navigating the file system and setting file paths.
Create and Manage Folders
Explains how to create new directories within the file system.
Rename and Delete Files/Folders
Guides on renaming files and deleting files or folders.
Copy File to USB
Details copying files from internal memory to a USB drive.
HARDCOPY KEY FUNCTIONS
Printer I/O Configuration
Covers connecting a PictBridge printer and configuring USB device port settings.
Print Output Procedures
Explains printing the display image using the Hardcopy key and Ink Saver function.
Save Functionality via Hardcopy Key
Details saving screen shots, waveforms, or setups using the Hardcopy key.
Image File Format Options
Explains selecting file formats (BMP, PNG) for saved image files.
Ink Saver Functionality
Explains using Ink Saver to achieve a white background for image files.
REMOTE CONTROL CONFIGURATION
Interface Configuration: USB
Guides on configuring the USB interface for computer connection.
USB Functionality Check
Explains how to check USB functionality using a terminal application.
Ethernet Interface Configuration
Covers configuring Ethernet settings like IP address and domain name.
Socket Server Configuration
Details setting up the socket server for remote communication over LAN.
Socket Server Functionality Check
Guides on testing socket server functionality using NI Measurement & Automation Explorer.
MAINTENANCE OPERATIONS
Signal Path Compensation (SPC) Function
Explains using SPC to compensate internal signal path for ambient temperature accuracy.
Vertical Accuracy Calibration
Guides on performing vertical accuracy calibration for the oscilloscope channels.
Probe Compensation Procedure
Details connecting the probe and adjusting for optimal square waveform.
Frequently Asked Questions (FAQ)
Troubleshooting Display and Signal Issues
Addresses common issues like signal not appearing, frozen waveform, or probe distortion.
Measurement and Setting Adjustments
Covers issues with Autoset, printout darkness, date/time, and accuracy.
APPENDIX
Firmware Update Procedure
Guides on downloading and updating the oscilloscope firmware via USB.
MDO-2000A Series Specifications
Provides detailed specifications for model-specific and common features.
Probe Specifications
Lists specifications for compatible probes like GTP-100B-4, GTP-200B-4, GTP-300B-4.
Dimensions and Declaration of Conformity
Provides instrument dimensions and compliance declarations.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the MDO-2202A and is the answer not in the manual?
Questions and answers