Connect RHE16 Transmitter via USB cable to your PC (mini USB connection on the front side of the RHE16 Transmitter). If the RHE16 Transmitter is connected to your PC for the first time a driver is installed automatically. This will take up a few seconds to two minutes. If the driver is not installed please look on page 8 for troubleshooting.
Connection Configuration - Troubleshooting If the RHE16 is connected to the computer for the first time a driver is installed automatically in the background. This will take up a few seconds to two minutes. The RHE16 transmitter can only be connected to the RHE16Com Software after the installation of the driver is finished.
RHE16Com Software Dashboard 1: General Information 2: Totalizer 3: Temperatures 4: Filter 5: Diagnostics 6: Zeroing & Cutoff Limit 7: Error and Warning Status 8: Output Overview T h e C o r i o l i s E x p e r t s...
RHE16Com Software 4. Filter Displays a constant applied to select measurement data for averaging the Time Mass Flow Rate. The higher the filter value the longer the time which is Constant used to average the Mass Flow Rate. T h e C o r i o l i s E x p e r t s...
After loading the parameters By pushing the Load / Merge – the current parameters are the Upload to RHE16 - Button has to be Button parameters saved in a .csv-file saved in a .csv-file pushed to take over the parameters...
Change and check respective values Upload new configuration to RHE16 Progress bar shows when configuration is transmitted to RHE16 T h e C o r i o l i s E x p e r t s...
Configure range of value and confirm by pushing on “OK / Configure“ - Button Progress bar shows when configuration is transmitted to RHE16 T h e C o r i o l i s E x p e r t s...
Select unit for chosen value and confirm by pushing on “OK / Configure“ Button Progress bar shows when configuration is transmitted to RHE16 T h e C o r i o l i s E x p e r t s...
RHE16Com Software Data Monitoring, Logging and Chart Part 1 Open Data Selection menu Select Monitoring and/or Chart and/or Logging option Confirm by pushing on “OK / Configure“ Button T h e C o r i o l i s E x p e r t s...
RHE16Com Software Data Monitoring, Logging and Chart Part 2 Monitoring Start / Stop Data Logging Logging (.csv) files saved under: Chart C:\Users\User\Documents\Rheonik\RHE16 T h e C o r i o l i s E x p e r t s...
1 to 0 or the other way round and checked to switch the direction of the positive flow rate. Upload new configuration to RHE16. Progress bar shows when configuration is transmitted to RHE16. T h e C o r i o l i s E x p e r t s...
Page 27
T h e C o r i o l i s E x p e r t s www.rheonik.com...