Cold Temperature Alarm - Sub-Zero 424HAG/O-2 Service Manual

400-2 series
Table of Contents

Advertisement

Electronic Control System
Wine Storage
Series
Wine Storage
Series
2
2
(400-
)
(400-
)

Cold Temperature Alarm

A cold temperature alarm can occur if either wine storage compartment remains below 38°F / 3°C for too long, caus-
ing several consecutive maximum run-time cycles. During a cold temperature alarm, cold temperature readings may
be displayed at the control panel, the SERVICE indicator will flash (See Figure 3-22). A cold temperature alarm also
cuts power to the compressor and fans, and logs error code "11" or "13" (covered later in this section), depending on
the compartment experiencing the cold temperature alarm. If the temperature alarm feature has been enabled by
pressing the bell key on the control panel, the BELL ON indicator will also flash, and the audible alarm will beep.
(See Figure 3-23)
NOTE: To clear the cold temperature alarm, the problem must be corrected, then press the UNIT ON/OFF key to
switch the unit Off, then press it again to switch the unit back ON. (See Figure 3-24) Also see Clearing Error
Codes, later in this section.
Figure 3-22. Cold Temperature Alarm, "SERVICE" Flashing
Figure 3-23. Cold Temperature Alarm with BELL ON Feature Enabled,
"SERVICE" and "BELL ON" Flashing with Audible Alarm Beeping
Figure 3-24. Clear Cold Temperature Alarm, Press UNIT ON/OFF Key to Off, Then ON
(Also see Clearing Error Codes, later in this section.)
3-14
#3758410 - Revision C - May, 2014