padSetNumVar
Sets a variable with given numeric data.
Syntax
BOOL padSetNumVar(
char FAR *lpszVarName,
WORD wValue
)
Parameter
lpszVarName
wValue
Returns
Returns TRUE if successful, FALSE otherwise.
See Also
padGetNumVar
padSetPadMode
Sets the Transaction Team 1500's operational mode. When in native mode, the device does not emulate any other
device. When in PenWare 100 emulation mode, the device's touch surface behaves as if it had the DPI resolution of
a PenWare 100.
Mode 0 = native mode
Mode 1 = PenWare 100 emulation
Syntax
BOOL padSetPadMode(
BYTE Mode
)
Parameter
Mode
Returns
Returns TRUE if successful, FALSE otherwise.
See Also
padSetPadOffset, padSetClearButton
Description
Name of the variable to which the numeric value is assigned
Value
Description
Specifies the mode the Transaction Team device should be set to
3 - 57