INSTALL THE EXHAUST DUCT

The exhaust of the hood must be well maintained in order to exhaust the cooking fumes as well as possible. You may choose
between an exhaust duct to the outside or connecting the exhaust duct to an exhaust box with a monoblock recirculation filter.
Information about the exhaust box is to be found in chapter 6.
For optimum performance of the hood it is important to pay attention to the points given below.
When using a round exhaust duct:
Use smooth, non-fla mmable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. The UP_SIDE requires an exhaust duct of Ø150 mm. Maximally extend flexible ducts and cut them to
size.
Do not reduce the exhaust diameter. This will decrease the capacity and increase the noise level.
When connecting to a short exhaust duct, it may be required to mount a non-return valve TSKE in the duct to prevent the
wind from blowing in.
Use a hose clamp or aluminium tape for airtight connections.
In case of an exhaust pipe through the outside wall, use the outside wall grate type MGE.
When using a flat exhaust duct:
Use flat ducts with rounded corners and air conductors in the bends. These ducts are to be obtained through Novy.
In case of restricted space in the cabinet, you can order an adapter as an option (item number 7901.052). For additional
information see chapter 5.
Make use of the connecting piece when connecting the flat duct to the outlet of the UP_SIDE.
General:
Make the duct as short as possible and with as few as possible bends to the outside.
Avoid square bends. Use rounded bends for proper air conduction.
If an exhaust pipe through the outside wall passes a cavity wall, make sure that the exhaust duct fully bridges the cavity
and slightly declines to the outside.
In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
Never connect the exhaust to a flue duct.
Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside door or by
installing an inlet grate.
Use the delivered white insulating tape for an airtight seal (801-006).
2.4
APPLIANCE ADJACENT TO THE UP_SIDE
For surface mounting and flush mounting
On the appliance that is not placed above the motor casing of UP_SIDE the delivered black PVC strip (7900-094) must
be applied at the front and the rear. This is to set off the difference in height.
Stick the strip at the front and at the rear.
For surface mounting:
Place the domino and/or induction hotplate besiUP_SIDE.
For flush mounting:
Place the appliance(s) besiUP_SIDE. The drip tray is just not touching the decorative frame of the UP_SIDE.