INSTALLATION
Proceed following the mounting drawings on pages 2 and 3.
Create an installation opening:
1
Type 6810 / 6811 / 6812 – Cut-away 845mm x 485mm
Type 6820 / 6821 / 6822 – Cut-away 1145mm x 485mm
The ceiling unit can be built into plates with a thickness of 18-35mm. Do not mount directly into gypsum board;
always make sure there is reinforcement for the tightening of the mounting clamps. Make sure there is a socket
near the ceiling unit, so that the power may, at all times, be removed from the ceiling unit.
Because of the substantial own weight of the hood, the ceiling must have sufficient load bearing capacity.
The recommended mounting height for an electric or ceramic cooking plate is min. 600 mm and max. 1600mm.
The mounting height for a gas or induction cooking plate is min. 650 mm and max. 1600mm.
2
Change the direction of the motor (if required).
- Open the lower plate and remove the filters from the hood.
- Loosen the 8 screws in accordance with the drawing.
3
Turn the motor so the exhaust is in the desired position and screw the motor with the 8 screws.
4
In order to simplify the installation, it is advisable to make the final piece between the flat duct work and hood from
flexible, flat exhaust channel. This is available as accessory from Novy (906.408).
5
If the flexible flat exhaust channel is to be used, connect the flexible exhaust channel onto the connection piece with
tape (taking the length of the flexible exhaust channel into account).
6
Click the connection piece (6810.030) onto the motor housing.
Suitable for flat exhaust charge channel with (internal) dimension of 89 x 222 mm.
7
Put the plug into the socket.
Push the ceiling unit up into the build-in opening by pushing on the edges (not on the lower plate) until you hear a firm
click. The ceiling unit will now remain suspended in place.
8
Tighten the 4 clamping screws by hand in order to attach the ceiling unit (caution: Do not over-tighten in gypsum
boards). As soon as these clamping screws are tightened, the ceiling unit is ready for use.
Removing the ceiling unit
9
Before dismounting, protect the cooking plate, for example using cardboard or cloth, in case a screw or clamp is
dropped onto it. To remove the ceiling unit, the 4 clamping screws have to be fully loosened. When these are loose,
the ceiling unit can be taken down. Watch out: the loosened clamping springs may drop down.

INSTALL THE EXHAUST DUCT

For optimum performance of the hood it is important to pay attention to the points given below during the installation.
The hood has a connection for flat exhaust channel. If necessary, this can be transferred to a circular exhaust channel of
Ø 150 mm at a later stage.
When using a flat exhaust duct:
• Use flat ducts with rounded corners and air conductors in the bends. These ducts are to be obtained through Novy.
• Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will reduce the capacity and increase the noise level.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve to prevent the wind from
blowing in.
• Use a hose clamp or aluminium tape for airtight connections.
• In case of an exhaust pipe through the outside wall, use the outside wall grille.
EN 14