3 IMPORTANT NOTICES

3.1 INSTALLATION REGULATIONS

-
When active, the element and the termowells have to be surrounded with a sufficient amount of
water from all sides.
-
Thermic water flow must not be prevented.
-
Mounting positions – horizontal or vertical from under.
-
The length of the 6/4 " neck shall not exceed 70 mm. If longer, the variant with an extended cooling
compartment has to be used.
-
If the length of the neck is within 100 mm, it has to be extended on the water side, or undercut in
a minimum length of 40 mm to the minimal diameter of 50 mm.
-
The maximum pressure in the tank is 10 bar.
Both the electric and water installation must follow and meet the requirements and
regulations relevant in the country of use!

3.2 SPARE PARTS

Always state the type of the heating unit and the name of the spare part when placing an order.
Thermostat and safety fuse
Sealing ring
3.3 DISPOSAL OF PACKAGING MATERIAL AND NON-
FUNCTIONING PRODUCT
A service fee for providing return and recovery of packaging material has
been paid for the packaging in which the product was delivered. The service
fee was paid pursuant to Act No 477/2001 Coll., as amended, at EKO-KOM
a.s. The client number of the company is F06020274. Take the water heater
packages to a waste disposal place determined by the town. When the
operation terminates, disassemble and transport the discarded and
unserviceable heater to a waste recycling centre (collecting yard), or contact
the manufacturer.