4.3 G-Force Setup
Pos Alarm:
This enables or disables the positive G-force alarm.
Pos Alarm:
Enter the G-force threshold for when the positive alarm must be activated. Any G-force above this value will activate the
alarm.
Neg Alarm:
This enables or disables the negative G-force alarm.
Neg Alarm:
Enter the G-force threshold for when the negative alarm must be activated. Any G-force below this value will activate the
alarm.
Pos Cycle:
Set the positive G-force limit above which the cycle counter should increment. This would typically be set to the maximum
allowable G-force rating of your aircraft (positive G-force). The cycle count is retained if power is removed.
Neg Cycle:
Set the negative G-force limit above which the cycle counter should increment. This would typically be set to the
maximum allowable G-force rating of your aircraft (negative G-force). The cycle count is retained if power is removed.