1
About this document
1.1
Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2
Target group: authorised qualified personnel . . . . . . . . . . . . . . . .1
1.3
Explanation of the symbols used. . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4
Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5
General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.6
Warning about misuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7
Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1
Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2
Special versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3
Included in delivery and accessories. . . . . . . . . . . . . . . . . . . . . . .2
2.3.1 Accessories included in delivery . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3.2 Optional accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4
Destination and use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.6
Safety classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7
Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7.1 Protective mode / standard operation . . . . . . . . . . . . . . . . . . . . . .3
2.7.3 Contactor control (EDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7.4 Testing / external test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.7.5 Signalling output / low-voltage safety output . . . . . . . . . . . . . . . . .3
3
3.1
General conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2
Protection field and approach . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3
Fixing of the sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4
3.5
Safety distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.5.1 Minimum distance to reflecting surfaces . . . . . . . . . . . . . . . . . . . .5
3.6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4
4.1
4.2
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4.3
Connector configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Encontrará el manual de
ES
idioma oficial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
ufficiale UE) è scaricabile in
Internet all'indirizzo
www.schmersal.net.
5
5.1
Check before start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.2
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.3
Regular check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5.4
Half-yearly inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6
6.1
LED status information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6.2
6.2.1 Protective mode / standard operation . . . . . . . . . . . . . . . . . . . . .9
6.3
Fault diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7
7.1
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7.2
Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8
8.1
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8.2
EC Declaration of conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1. About this document
1.1

Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.
1.2

Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.
1.3

Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional informa-
tion.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4

Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
EN
SLC 430
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLC 430 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SLC 430

  • Page 1: Table Of Contents

    Operating instructions Safety light curtain SLC 430 Set-up and maintenance Check before start-up ........8 Maintenance .
  • Page 2: General Safety Instructions

    Safety monitoring module NSR-0605, Cable set KA-0610 (cable length 5 m) Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www. 2.3.2 Optional accessory schmersal.net.
  • Page 3: Safety Classification

    Operating instructions Safety light curtain SLC 430 LED indications sensor R: OSSD ON, OSSD OFF, restart interlock The command devices (enabling button) must be installed (manual reset) enabling outside of the hazardous area. The operator must have a Sensor connection: M8 x 1, 4-pole shielded female connector;...
  • Page 4: Protection Field And Approach

    Approach speed Resolution of the safety light curtain Unauthorised installation Safety light curtain SLC 430 The safety distance for resolutions 14 mm up to 40 mm is calculated by Hazardous machine parts can be reached wit- means of the following formula: hout passing through the protection field.
  • Page 5: Minimum Distance To Reflecting Surfaces

    Operating instructions Safety light curtain SLC 430 Example: 3.5.1 Minimum distance to reflecting surfaces Reaction time of the safety light curtain = 50 ms During the installation, the effects of reflecting surfaces must be taken Resolution of the safety light curtain = 30 mm into account.
  • Page 6: Dimensions

    Operating instructions Safety light curtain SLC 430 Dimensions Mounting angle B90, angled All measurements in mm. 7. 5 7. 5 Mounting angle B180, straight Ø 3. 5 9. 7 4. 3 Type Weight of Protected Sensor the sen- height length with...
  • Page 7: Instrucciones Actual En Su

    Operating instructions Safety light curtain SLC 430 4. Electrical connection Power supply Hold function Test input Output 1 Output 2 Signalling output Sensor E Sensor R VDE 0551 VDE 0551 15-48 VDC 18-21 VAC *) Spark suppression MAX. 42 VDC/VAC...
  • Page 8: Connector Configuration

    Operating instructions Safety light curtain SLC 430 Cable screen at mounting angle The ground connection laid together with the connecting cables must be connected as shown to the E and R sensors through the fixation part. Sch. Sensor E/R Fixing part 5.
  • Page 9: Half-Yearly Inspection

    Operating instructions Safety light curtain SLC 430 7. The hazardous machine movement is immediately stopped, when NSR-0605 Buzzer the protection field is interrupted with the test rod immediately before the sensor E, immediately before the sensor R and in the middle Buzzer switch between the sensor E and R.
  • Page 10: Fault Diagnostic

    Tel:+49 (0) 202 64 74 -0 Fax:+49 (0) 202 64 74- 100 You will also find detailed information regarding our product variety on our website: www. schmersal.com Repair handling / shipping: Safety Control GmbH Am Industriepark 11 D-84453 Mühldorf / Inn...
  • Page 11: Ec Declaration Of Conformity

    44 205 10 555867 006 Place and date of issue: Wuppertal, February 1, 2010 Authorised signature Authorised signature Christian Spranger Klaus Schuster Managing Director Managing Director The currently valid declaration of conformity can be down- loaded from the internet at www.schmersal.net.
  • Page 12: En Operating Instructions

    Safety Control GmbH Am Industriepark 33 D-84453 Mühldorf / Inn Telefon +49 - (0)86 31 - 187 - 9 60 Telefax +49 - (0)86 31 - 187 - 9 61 E-Mail: info@safetycontrol.com...

Table of Contents