Advertisement

Error messages
Display
error source
540
Overheating of the drive unit
550
USB consumer
580
Software version
591
Authentication
592
Incompatible components
593
Configuration
595, 596
Communication
602
Rechargeable battery or charging error
of the rechargeable battery
603
Rechargeable battery
605
Temperature of the rechargeable battery
or charging error of the rechargeable
battery
606
Rechargeable battery connection
610
Rechargeable battery voltage error
620
Charger
640
Rechargeable battery
Measure
- 1)
Switch the e-bike off�
- 2)
Let the motor cool off�
- 3)
Select a low riding mode�
Disconnect the external device from the USB port and restart the e-bike.
Restart the e-bike
Switch the e-bike off� Remove the rechargeable battery and insert it again� Re-
start the e-bike�
Insert compatible display.
Restart the e-bike�
Check the cable connections and contacts (visual check)� Restart the e-bike�
- 1)
Restart the e-bike�
or
- 1)
Disconnect the charger from the rechargeable battery�
- 2)
Restart the e-bike�
- 3)
Connect the charger to the rechargeable battery�
Restart the e-bike�
Let the rechargeable battery reach the operating temperature�
or
Disconnect the charger from the rechargeable battery and let the rechargeable
battery and charger reach the operating temperature�
Check the cable connections and contacts�
Restart the e-bike�
Replace the charger� Only use an approved charger�
Restart the e-bike�