Table of Contents

Advertisement

Moving
Rehabilitation
Forward™
Therapy Systems
SERVICE MANUAL
®
Therapy Systems:
Genisys Therapy System
(Serial Numbers- 1000 and above)
Intelect Legend XT Therapy System
(Serial Numbers- 1000 and above)
Intelect Vet Therapy System
(Serial Numbers- 1000 and above)
Optional Accessories:
Channel 3/4 Electrotherapy Module
(Serial Numbers- 1000 and above)
NiMH Battery Module
(Serial Numbers- 1000 and above)
sEMG Module (Genisys Only)
(Serial Numbers- 1000 and above)
Laser Module (Genisys Only)
(Serial Numbers- 1000 and above)
Therapy System Cart
Operator Remote Control
ISO 13485 CERTIFIED

Advertisement

Table of Contents
loading

Summary of Contents for Chattanooga Group Vectra Genisys

  • Page 1 ® Therapy Systems: Genisys Therapy System (Serial Numbers- 1000 and above) Intelect Legend XT Therapy System (Serial Numbers- 1000 and above) Intelect Vet Therapy System (Serial Numbers- 1000 and above) Optional Accessories: Channel 3/4 Electrotherapy Module (Serial Numbers- 1000 and above) NiMH Battery Module (Serial Numbers- 1000 and above) sEMG Module (Genisys Only)
  • Page 3: Table Of Contents

    5.14 ULTRASOUND TESTS ........49 H. Vectra Genisys Dual Channel sEMG Module ....14 5.15 ULTRASOUND APPLICATOR IDENTIFICATION TEST .
  • Page 4 10.1 VECTRA GENISYS, INTELECT LEGEND XT, AND INTELECT VET THERAPY SYSTEM- CONTROL BOARD . . 88-90 10.2 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEM-ULTRASOUND PC BOARD ... . . 91-93 10.3 VECTRA GENISYS, INTELECT LEGEND XT AND...
  • Page 6: Foreword

    ©2008 Encore Medical, L.P. and its affiliates, Austin, Texas, USA. Any use of editorial, pictorial, or layout composition of this publication without express written consent from Chattanooga Group of Encore Medical, L.P. is strictly prohibited. This publication was written, illustrated, and prepared for distribution by Chattanooga Group of Encore Medical, L.P.
  • Page 7: 1 Theory Of Operation

    1 THEORY OF OPERATION 1.1 OVERVIEW The Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy Systems are comprised of several PC board assemblies housed within a common enclosure. These assemblies each support a distinct function in the product. The basic elements are User Interface, Control Board, Stim Board, Ultrasound Board, Ultrasound Applicator, and Power Supply Circuits.
  • Page 8 F. Therapy System Cart The Therapy System Cart is designed for use with the Chattanooga Group Therapy Systems only. The cart alone provides mobility to the Therapy System and storage of necessary accessories and supplies used in conjunction with the Therapy System.
  • Page 9: 2 Safety Precautions

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 2 SAFETY PRECAUTIONS Corrosive 2.1 PRECAUTIONARY DEFINITIONS The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this Text with a “CORROSIVE"...
  • Page 10: Precautionary Instructions

    • • Read, understand, and practice the precautionary and The Vectra Genisys Therapy System, the Intelect Legend XT operating instructions. Know the limitations and hazards Therapy System and the Intelect Vet Therapy System are not associated with using any laser device. Observe the designed to prevent the ingress of water or liquids.
  • Page 11 Therefore, when performing any the power source before attempting any maintenance operational or functional check, make certain all persons procedures. in the vicinity of the laser wear Chattanooga Group laser • Keep electrodes separated during treatment. Electrodes in protective eyewear.
  • Page 12: 3 Nomenclature

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3 NOMENCLATURE 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS A. Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy Systems The nomenclature graphic below, Figure 3.1, Refer to the respective pages of this section...
  • Page 13: Combination Therapy Systems

    3 NOMENCLATURE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) B. Vectra Genisys, Intelect Legend XT and Intelect Vet Combination Therapy Systems The nomenclature graphics below, Figure 3.2,...
  • Page 14: Vectra Genisys,Intelect Legend Xt And Intelect Vet Electrotherapy Systems

    3 NOMENCLATURE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) C. Vectra Genisys, Intelect Legend XT and Intelect Vet Electrotherapy Systems The nomenclature graphics below, Figure 3.3, Know the components and their functions...
  • Page 15: Vectra Genisys,Intelect Legend Xt And Intelect Vet Channel 3/4 Electrotherapy Module

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) D. Vectra Genisys, Intelect Legend XT and Intelect Vet Channel 3/4 Electrotherapy Module The nomenclature graphics below, Figure 3.4, Know the components and their functions...
  • Page 16: Vectra Genisysintelect Legend Xt And Intelect Vet Nimh Battery Module

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3 NOMENCLATURE 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) E. Vectra Genisys, Intelect Legend XT and Intelect Vet NiMH Battery Module The nomenclature graphic below, Figure 3.5,...
  • Page 17: Vectra Genisys And Intelect Vet Laser Module

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3 NOMENCLATURE 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) F. Vectra Genisys and Intelect Vet Laser Module The nomenclature graphic below, Figure 3.6, Know the components and their functions...
  • Page 18: Vectra Genisys And Intelect Vet Laser Applicators

    3 NOMENCLATURE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) G. Vectra Genisys and Intelect Vet Laser Applicators The nomenclature graphics below, Figure 3.7, Know the components and their functions...
  • Page 19: Vectra Genisys Dual Channel Semg Module

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3 NOMENCLATURE 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) H. Vectra Genisys Dual Channel sEMG Module The nomenclature graphics below, Figure 3.8, Know the components and their functions...
  • Page 20: Vectra Genisys, Intelect Legend Xt And

    3 NOMENCLATURE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) I. Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy System Cart The nomenclature graphics below, Figure 3.9,...
  • Page 21: Operator Remote Control

    3 NOMENCLATURE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3.1 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS (CONTINUED) J. Vectra Genisys, Intelect Legend XT and Intelect Vet Operator Remote Control The nomenclature graphics below, Figure 3.10,...
  • Page 22: Definitions

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 3 NOMENCLATURE 3.2 VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET THERAPY SYSTEMS HARDWARE AND SOFTWARE SYMBOL DEFINITIONS The symbol graphics below are found on the Know the symbols and their definitions before system as well as within the software.
  • Page 23: 4 Specifications

    Electrical Type Ultrasound (Combination Systems Only) and Laser Module (Vectra Genisys and Intelect Vet Only) ..TYPE B Electrotherapy, sEMG and Channel 3/4 Module ............TYPE BF...
  • Page 24: Electrotherapy Waveform Specifications

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.2 ELECTROTHERAPY WAVEFORM SPECIFICATIONS The specifications found in this section provide NOTE: the necessary waveform specifications to aid in All waveforms, except High Voltage Pulsed Current troubleshooting. A waveform graphic from an (HVPC), of the Vectra Genisys, Intelect Legend XT oscilloscope is also provided for clarification.
  • Page 25: Tens- Symmetrical Biphasic- Figure 4.4

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.2 ELECTROTHERAPY WAVEFORM SPECIFICATIONS (CONTINUED) C. TENS- Symmetrical Biphasic- Figure 4.4 (Vectra Genisys, and Intelect Legend XT) Output Mode ..... . . Electrodes Output Intensity .
  • Page 26: Vms ™ - Figure 4.6

    4 SPECIFICATIONS 4.2 ELECTROTHERAPY WAVEFORM SPECIFICATIONS (CONTINUED) E. VMS ™ - Figure 4.6 (Vectra Genisys, and Intelect Vet) Output Mode ..... . . Electrodes Output Intensity .
  • Page 27: Russian- Figure 4.8

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4 SPECIFICATIONS 4.2 ELECTROTHERAPY WAVEFORM SPECIFICATIONS (CONTINUED) G. Russian- Figure 4.8 (Vectra Genisys, Intelect Legend XT and Intelect Vet) Output Mode ..... . Electrodes Output Intensity .
  • Page 28: Vms ™ Burst- Figure 4.10

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.2 ELECTROTHERAPY WAVEFORM SPECIFICATIONS (CONTINUED) I. VMS ™ Burst- Figure 4.10 (Vectra Genisys) Output Mode ..... . . Electrodes Output Intensity .
  • Page 29: Ultrasound Specifications

    Treatment Time ..................1-30 Minutes Head Warming Feature The Head Warming feature of an Vectra Genisys, Intelect Legend XT or Intelect Vet Combination Therapy System utilizes Ultrasound output resulting in warming of the Sound Head to increase patient comfort.
  • Page 30: Description Of Device Markings

    4 SPECIFICATIONS 4.4 DESCRIPTION OF DEVICE MARKINGS The markings on the Vectra Genisys Therapy System, the Intelect Legend XT Therapy System and the Intelect Vet Therapy System are your assurance of their conformity to the highest applicable standards of medical equipment safety and electromagnetic compatibility.
  • Page 31: Laser Module Specifications

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.5 LASER MODULE SPECIFICATIONS VECTRA GENISYS AND INTELECT VET This section provides the necessary Laser Refer to these specifications as necessary when Module and Applicator Specifications to aid in troubleshooting the Laser Module and Applicators.
  • Page 32: Laser Applicator Specifications

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4 SPECIFICATIONS 4.6 LASER APPLICATOR SPECIFICATIONS VECTRA GENISYS AND INTELECT VET A. Single Diode Applicators NOTE: No Field Service is applicable to the Laser Module or Laser Applicators. All Laser Modules and Applicators suspected to require service or calibration must be sent to the factory.
  • Page 33: 9, 13, And 19 Diode Applicators

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.6 LASER APPLICATOR SPECIFICATIONS VECTRA GENISYS AND INTELECT VET (CONTINUED) B. 9, 13, and 19 Diode Applicators NOTE: No Field Service is applicable to the Laser Module or Laser Applicators. All Laser Applicators suspected to require service or calibration must be sent to the factory.
  • Page 34: 33 Diode Applicators

    4 SPECIFICATIONS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 4.6 LASER APPLICATOR SPECIFICATIONS VECTRA GENISYS AND INTELECT VET (CONTINUED) C. 33 Diode Applicators NOTE: No Field Service is applicable to the Laser Module or Laser Applicators. All Laser Applicators suspected to require service or calibration must be sent to the factory.
  • Page 35: 5 Troubleshooting

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES A. The information provided below is intended to Error messages in the range of 100 to 199 are aid in defining the Software Error Messages of the...
  • Page 36 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) Code Type Probable Cause Possible Remedies Number Message Warning Attempting to save additional User Protocols or Sequences after Delete some User Protocols or Sequences. Refer to appropriate section of the Therapy system memory has reached the maximum allowed (200).
  • Page 37 Number Message Warning Control Board Software upgrade warning. Upgrade Control Board Software to latest version. Contact dealer or Chattanooga Group for latest software upgrade and instructions. Warning Stim Board Main Software upgrade warning. Upgrade Stim Board Software to latest version. Contact dealer or Chattanooga Group for latest software upgrade and instructions.
  • Page 38 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) ERROR MESSAGES REQUIRING TECHNICAL ASSISTANCE 200299 Code Type Probable Cause Possible Remedies Number Message Error Error reading the system Real Time Clock (RTC) Replace Control Board Error Internal List Box Memory Error.
  • Page 39 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) ERROR MESSAGES REQUIRING TECHNICAL ASSISTANCE 200299 Code Type Probable Cause Possible Remedies Number Message Error Error while performing a Software upgrade. A. Turn Therapy System Off and back On. Reattempt upgrade.
  • Page 40 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) CRITICAL ERRORS DEMANDING TECHNICAL SERVICE 300399 Code Type Probable Cause Possible Remedies Number Message Critical Error Stim Board not found on Power up. A. On Therapy System, make certain internal Ribbon Cable is seated on Stim PC Board and Control Board.
  • Page 41 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) CRITICAL ERRORS DEMANDING TECHNICAL SERVICE 300399 Code Type Probable Cause Possible Remedies Number Message Critical Error Error reading from Stim Board. A. On Therapy System, make certain internal Ribbon Cable is seated on Stim PC Board and Control Board.
  • Page 42 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.1 THERAPY SYSTEM ERROR MESSAGES (CONTINUED) B. The information provided below is intended to NOTE: aid in additional troubleshooting of the Vectra No Field Service is applicable to the Laser Module Genisys, Intelect Legend XT or Intelect Vet or Laser Applicators.
  • Page 43: Therapy System Testing

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.2 THERAPY SYSTEM TESTING A. General Ultrasound Applicators (Accessories) Dielectric Withstand (Hi-Pot) and ground The following information is intended to aid resistance tester in troubleshooting the major components of the Vectra Genisys, Intelect Legend XT NOTE: and Intelect Vet Therapy Systems to “Board...
  • Page 44: Visual Inspection

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.3 VISUAL INSPECTION Visually inspect the Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy Systems. A visual inspection can, to an experienced technician, indicate possible abuse of the unit and internal problems.
  • Page 45: Stimulator Test System Setup

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.6 STIMULATOR TEST SYSTEM SETUP The following tests for Stimulator Outputs will be performed on Channels 1 and 2. The performance of these same tests will apply to the Channel 3 and 4 Electrotherapy Module for four channel therapy systems.
  • Page 46: Vms™ Mode Test

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5 TROUBLESHOOTING 5.7 VMS™ MODE TEST A. VMS™ Mode Test Procedures Set Scope; Time- 100 μS, Channel- 50 V, and Trigger- DC Press Electrotherapy Button. Press VMS Button and then press Edit Button.
  • Page 47: Interferential Mode Test

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5 TROUBLESHOOTING 5.8 INTERFERENTIAL MODE TEST It is assumed that the unit is ready for tests as described in 5.6 parts A and B. If not, Set up Unit per 5.6 parts A and B prior to performing tests.
  • Page 48: Premodulated Mode Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.9 PREMODULATED MODE TEST Set up System per 5.6 parts A and B prior to performing test. A. Premodulated Mode Test Procedures Set Scope; Time- 2.50 mS, Channel- 20 V, and Trigger- DC.
  • Page 49: Russian Mode Test

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5 TROUBLESHOOTING 5.10 RUSSIAN MODE TEST Set up System per 5.6 parts A and B prior to performing test. A. Russian Mode Test Procedures Set Scope; Time- 5 mS, Channel- 50 V, and Trigger- DC.
  • Page 50: Microcurrent Mode Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.11 MICROCURRENT MODE TEST NOTE: This test does not apply to the Intelect Vet Therapy System. LOAD SWITCH TO 10K MICRO Set up System per 5.6 parts A and B prior to performing test.
  • Page 51: High Voltage Pulsed Current Hvpc Mode Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.12 HIGH VOLTAGE PULSED CURRENT HVPC MODE TEST PROPER NEGATIVE HIGH VOLT WAVEFORM Set up Unit per 5.6 parts A and B prior to performing tests. A. High Voltage Pulsed Current (HVPC) Mode Test Procedures Set Scope;...
  • Page 52: Microcurrent Probe Mode Test

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5 TROUBLESHOOTING 5.13 MICROCURRENT PROBE MODE TEST NOTE: This test does not apply to the Intelect Vet Therapy System. Set up Unit per 5.6 parts A and B prior to performing tests.
  • Page 53 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.13 MICROCURRENT PROBE MODE TEST (CONTINUED) B. MicroCurrent Probe Mode Test Results Unit performs as described in steps 5-7 and 10. Unit passed test. No Search Mode Beep. Unit failed test. Try a known good Microcurrent Probe and repeat test.
  • Page 54: Ultrasound Tests

    Ultrasound Applicator. 5.15 ULTRASOUND APPLICATOR IDENTIFICATION TEST NOTE: FIGURE 5.18 Use any Vectra Genisys, Intelect Legend XT or Intelect Vet Ultrasound Applicator for this test. A. Ultrasound Applicator Identification Test Procedures Without Applicator installed, turn unit on. Look at the “Ultrasound” channel icon at the lower Left Hand corner of screen.
  • Page 55: Ultrasound Applicator Output Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.16 ULTRASOUND APPLICATOR OUTPUT TEST Perform this test using all available Vectra Genisys, Intelect Legend XT or Intelect Vet Applicators for the System being tested. A. Ultrasound Applicator Output Test...
  • Page 56: Ultrasound Duty Cycle Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.17 ULTRASOUND DUTY CYCLE TEST This test is performed using only the 5 cm Vectra Genisys, Intelect Legend XT or Intelect Vet Applicator. A. Ultrasound Duty Cycle Test Procedures Set up Ohmic Instruments UPM DT 10 or DT 100 Ultrasound Power Meter per Operator’s Instructions and fill test...
  • Page 57: Combo Operation Test

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.18 COMBO OPERATION TEST This test is performed using the 5 cm Applicator. Select Channel 2 and set up System per 5.6 parts A and B prior to performing tests.
  • Page 58: Semg And Semg + Electrical Stimulation Tests

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.19 SEMG AND SEMG + ELECTRICAL STIMULATION TESTS ATTENUATOR SCHEMATIC NOTE: This test is for only the Vectra Genisys Therapy 100K 1% System with properly installed sEMG. Perform this test on all Channels with sEMG. However, 49.9 OHM 1%...
  • Page 59 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.19 SEMG AND SEMG + ELECTRICAL STIMULATION TESTS (CONTINUED) If icons are present, connect known good sEMG Lead Wire to Channels 1 and 2. See Figure 5.31. NOTE: Only one Channel at a time can be tested for sEMG.
  • Page 60 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.19 SEMG AND SEMG + ELECTRICAL STIMULATION TESTS (CONTINUED) 7. Make certain the Audio Signal Generator is set up per 5.19, part B, steps 1, a) through 1, g). Connect the Audio Signal...
  • Page 61 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.19 SEMG AND SEMG + ELECTRICAL STIMULATION TESTS (CONTINUED) D. sEMG + STIM Tests To Check Stim Output, conduct the Electrical Stimulator Tests as explained in 5.6 through 5.13. Set up Signal Generator and Attenuator as described in 5.19, part B.
  • Page 62: Nimh Battery Module Checks

    5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.20 NIMH BATTERY MODULE CHECKS The following checks for the NiMH Battery Module are to check for possible damage to the Battery Cells and proper connections within the module and module to System connection.
  • Page 63 5 TROUBLESHOOTING Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 5.20 NIMH BATTERY MODULE CHECKS CONTINUED Using the Flat Blade Screwdriver, carefully release the tabs retaining the top plate in position. It will be necessary to lift with one hand while releasing the tabs with the Screwdriver.
  • Page 64: 6 Removal/Replacement

    The following procedures apply to all Channel 3/4 REMOVE FRONT ACCESS Electrotherapy, NiMH Battery, and Laser Modules PANEL AND DISCONNECT (Vectra Genisys and Intelect Vet) that mount to the ALL CABLES base of a Therapy System. B. Module Installation Disconnect Therapy System from the power source.
  • Page 65 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.1 CHANNEL 3/4 ELECTROTHERAPY, NIMH BLUE STRIP BATTERY, AND LASER MODULE INSTALLATION AND REMOVAL CONTINUED DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE,...
  • Page 66 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.1 CHANNEL 3/4 ELECTROTHERAPY, NIMH BATTERY, AND LASER MODULE INSTALLATION AND REMOVAL CONTINUED DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE,...
  • Page 67 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.1 CHANNEL 3/4 ELECTROTHERAPY, NIMH BATTERY, AND LASER MODULE INSTALLATION AND REMOVAL CONTINUED Install all cables, Lead Wires, etc. to the Therapy System and Module where applicable. Refer to page 14 for Symbol Definitions.
  • Page 68: Semg Module Installation And Removal

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems EMG MODULE INSTALLATION AND NOTE: REMOVAL VECTRA GENISYS ONLY Twist the Screwdriver to break tabs free. Carefully remove tabs so as not to cause any damage to the PC Board Contacts below the tabs.
  • Page 69 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems EMG MODULE INSTALLATION AND REMOVAL VECTRA GENISYS ONLY CONTINUED DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 70 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems EMG MODULE INSTALLATION AND REMOVAL VECTRA GENISYS ONLY CONTINUED Turn the System On using the On/Off Switch. The system will automatically recognize the added module and display a configuration change message. See Figure 6.16.
  • Page 71: Therapy System Separating Top & Bottom

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.3 THERAPY SYSTEM SEPARATING REMOVE 4 SCREWS TOP & BOTTOM DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 72 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.3 THERAPY SYSTEM SEPARATING TOP & BOTTOM CONTINUED DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 73: Therapy System Fan

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6 REMOVAL/REPLACEMENT 6.4 THERAPY SYSTEM FAN DISCONNECT THE SYSTEM FROM THE POWER REMOVE SOURCE (OUTLET OR REMOVE BATTERY MODULE IF SCREWS INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 74: Therapy System Control Board Assembly

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.5 THERAPY SYSTEM CONTROL BOARD POWER ASSEMBLY DISTRIBUTION BOARD DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 75: Therapy System Keymat Assembly

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.6 THERAPY SYSTEM KEYMAT ASSEMBLY DISCONNECT THE SYSTEM FROM THE POWER REMOVE SOURCE (OUTLET OR REMOVE BATTERY MODULE IF RETAINING INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, SCREWS INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 76: Therapy System Connector Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6 REMOVAL/REPLACEMENT 6.7 THERAPY SYSTEM CONNECTOR BOARD DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 77: Therapy System Ultrasound Board Combination Systems Only

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6 REMOVAL/REPLACEMENT 6.8 THERAPY SYSTEM ULTRASOUND BOARD COMBINATION SYSTEMS ONLY DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 78: Therapy System Stim Board Channels 1/2

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.9 THERAPY SYSTEM STIM BOARD CHANNELS 1/2 SLOT 90° TO LOCKED INDICATOR DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE,...
  • Page 79: Therapy System Power Supplies

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6 REMOVAL/REPLACEMENT 6.10 THERAPY SYSTEM POWER SUPPLIES NOTE: The Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy Systems incorporate two different Power Supply configurations: Combination Therapy System- Two Power Supplies, one 75 Watt for Ultrasound Power and one 100 Watt to power the rest of the system.
  • Page 80 6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.10 THERAPY SYSTEM POWER SUPPLIES CONTINUED MAINS WIRING HARNESS DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, PLIERS NOT INSTALLATION, REMOVAL, OR REPLACEMENT...
  • Page 81: Channel 3/4 Electrotherapy Module

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.11 CHANNEL 3/4 ELECTROTHERAPY MODULE CONNECTOR BOARD DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 82: Channel 3/4 Electrotherapy Module Stim Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6 REMOVAL/REPLACEMENT 6.12 CHANNEL 3/4 ELECTROTHERAPY MODULE STIM BOARD DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 83: Mounting And Dismounting Therapy System And Therapy System Cart

    6 REMOVAL/REPLACEMENT Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 6.13 MOUNTING AND DISMOUNTING THERAPY SYSTEM AND THERAPY SYSTEM CART DISCONNECT THE SYSTEM FROM THE POWER SOURCE (OUTLET OR REMOVE BATTERY MODULE IF INSTALLED) BEFORE ATTEMPTING ANY MAINTENANCE, INSTALLATION, REMOVAL, OR REPLACEMENT PROCEDURES TO PREVENT ELECTRICAL SHOCK AND POSSIBLE DAMAGE TO SYSTEM.
  • Page 84: 7 General Maintenance

    7 GENERAL MAINTENANCE Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 7.2 CALIBRATION REQUIREMENTS A. Ultrasound Applicators: Annual factory calibration is required for all DISCONNECT THE SYSTEM FROM THE POWER Ultrasound Applicators. Only the Applicators SOURCE (OUTLET OR REMOVE BATTERY MODULE IF...
  • Page 85: 8 Ultrasound Calibration

    8 ULTRASOUND CALIBRATION Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 8.1 GENERAL A. Tools and Equipment Required THERAPY SYSTEMS WITH Vectra Genisys, Intelect Legend XT and the SOFTWARE VERSION 2.0 OR Intelect Vet Combination Therapy System ABOVE and all Vectra Genisys, Intelect Legend XT and the Intelect Vet Ultrasound Applicators associated with the System being serviced.
  • Page 86: 9 Parts

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems TOP TO BOTTOM ASSEMBLY TOP ASSEMBLY SEE PAGE 84 BOTTOM ASSEMBLY SEE PAGE 82 ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27159 Bottom Assembly to Top Assembly Ribbon Cable 27306 Rear Access Panel...
  • Page 87: Combination System Base Assembly

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems COMBINATION SYSTEM BASE ASSEMBLY STIM & ULTRASOUND BOARD ASSEMBLY SEE PAGE 83 ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27022 Mains Harness Clip 27276 Main Power Switch 27277 Mains Power Input Connector...
  • Page 88: Combination Stim & Ultrasound Pc Board Assembly

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems COMBINATION STIM & ULTRASOUND PC BOARD ASSEMBLY ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27055 Ultrasound PC Board 27161 Ultrasound to Stim Header 27160 PC Board Stand Off 27057 Stim PC Board...
  • Page 89: Top Housing Assembly

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems TOP HOUSING ASSEMBLY 1, 1A and 1B 7  7A 2  2A 3  3A 6  6A CONTROL BOARD ASSEMBLY SEE PAGE 85 AND 86 ITEM PART DESCRIPTION...
  • Page 90: Vectra Genisys And Intelect Vet

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems VECTRA GENISYS AND INTELECT VET CONTROL BOARD ASSEMBLY ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27093 Color Display Mounting Bracket/Spacer 27162 Color Display 27012 Contrast Knob (Not Functional) 27053 Color Control PC Board...
  • Page 91: Intelect Legend Xt Control Board Assembly

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems INTELECT LEGEND XT CONTROL BOARD ASSEMBLY ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27512 Screw, M3 x 4 mm 27180 Monochromatic LCD 27145 Stand Off, M3 x 10 mm 27012 Contrast Knob (Functional)
  • Page 92: Channel 3/4 Electrotherapy Module Assembly

    9 PARTS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems CHANNEL 3/4 ELECTROTHERAPY MODULE ASSEMBLY ITEM PART DESCRIPTION NUMBER NUMBER REQ'D 27015 Module Top 27353 Stim Board to Ribbon Cable Header 27057 Stim PC Board 27016 Module Bottom Housing 27150...
  • Page 93: 10 Schematics

    10 SCHEMATICS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems...
  • Page 94 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 95 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 96: Therapy System-Ultrasound Pc Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 97 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 98 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 99: Intelect Vet Therapy System- Stim Board

    10 SCHEMATICS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems...
  • Page 100 10 SCHEMATICS Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems...
  • Page 101 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 102 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 103 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 104 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 105 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 106 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 107 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 108 Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 109: Intelect Vet Therapy System- Connector Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 110: Connector Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 111: Therapy System- Power Supplies

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 112: System- Laser Module Board

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems 10 SCHEMATICS...
  • Page 113: 11 Warranty

    Vectra Genisys®/Intelect Legend XT®/ Intelect® Vet Therapy Systems VECTRA GENISYS, INTELECT LEGEND XT AND INTELECT VET Chattanooga Group, a division of Encore Medical, L.P. ("Company") warrants that the Vectra Genisys, Intelect Legend XT and Intelect Vet Therapy Systems, Channel 3/4 Electrotherapy Module, Laser Module, and sEMG Module ("Products") are free of defects in material and workmanship.
  • Page 114 Moving Rehabilitation Forward™ ISO 13485 CERTIFIED 4717 Adams Road P.O. Box 489 Hixson, TN 37343 U.S.A. 1-423-870-2281 U.S.A. 1-800-592-7329 U.S.A. 1-423-875-5497 U.S.A. FAX chattgroup.com *28047* 28047D © 2008 Encore Medical, L.P.

This manual is also suitable for:

Intelect vetIntelect legend xt

Table of Contents