D. Tools And Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
Reciprocating saw
Pliers
Hammer
Phillips screwdriver
Flat blade screwdriver
Plumb line
Level
Misc. screws and nails
1/2-3/4 in. length, #6 or #8 self-drilling screws
E. Inspection of Appliance and Components
Remove appliance and components from packaging
and inspect for damage.
Report to your dealer any parts damaged in shipment.
Read all the instructions before starting the installation.
Follow these instructions carefully during the installation
to ensure maximum safety and benefit.
WARNING
Fire Risk.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
www.heatilator.com
Framing material
High temp caulking material
Gloves
Framing square
Electric drill and bits
Safety glasses
Tape measure
7/16 socket or wrench
7056-153F • 20 August, 2018
F. Draft
Draft is the pressure difference needed to vent appliances
successfully. When a appliance is drafting successfully, all
combustion by products are exiting the home through the
chimney.
Considerations for successful draft include:
Preventing negative pressure
Location of appliance and chimney
To be sure that your appliance burns properly:
During a low burn, the chimney draft (static pressure)
should be approximately -.04 inch water column (W.C.)
During a high burn the chimney draft should be
approximately -.10 inch (W.C.)
Measure the W.C at 6 inches (152mm) above the top
of the appliance after one hour of operation at each
burn setting.