Keysight Technologies PNA-L N5230A Configuration Manual page 6

Pna series microwave network analyzers

Advertisement

PNA-X Network Analyzers N5242A, 10 MHz to 26.5 GHz, 2 or 4 Ports
Options
To add options to a product, order the corresponding item number.
Description
Test set
Option 200
2 ports, single source
Option 224
2 ports, add internal 2nd source, combiner and mechanical
switches
Option 400
4 ports, dual source
Option 423
4 ports, add internal combiner and mechanical switches
Power configuration
Option 219
2 ports, extended power range and bias-tees
Option 419
4 ports, extended power range and bias-tees
Option H85
High-power configuration
Measurement applications
Option 010
Time-domain measurements
1
Option 029
Fully-corrected noise figure measurements
Option 080
Frequency offset
2
Option 082
Scalar-calibrated converter measurements
2
Option 083
Vector- and scalar-calibrated converter measurements
Option 084
Embedded LO measurements
Option 086
Gain compression application
3
Option 551
N-port capabilities
Pulse, antenna, mm-wave
Option H08
Pulse measurements
Option 020
Add IF inputs for antenna and mm-wave
Option 021
Add pulse modulator to internal 1st source
Option 022
Add pulse modulator to internal 2nd source
Option 025
Add four internal pulse generators
Accessories
Option 1CM
Rack mount kit for use without handles
N1966A
Pulse I/O adapter
N4688A
USB CD R/W drive
N4689A
USB Hub
Calibration Software
4
Option 897
Perpetual license for built-in performance test software for
Keysight inclusive calibration
Option 898
4
Perpetual license for built-in performance test software for
standards compliant calibration
Calibration documentation
Option 1A7
ISO 17025 compliant calibration
Option UK6
Commercial calibration certificate with test data
Option A6J
ANSI Z540 compliant calibration
1.
In addition to the list of required PNA-X options, Option 029 requires an N4691B ECal module for use as an impedance tuner, and a Keysight 346 series noise source for calibration.
2.
Option 082 is a subset of Option 083, and therefore, they can not be ordered together.
3.
When configured as a multiport analyzer with Option 551, the combiner feature of Option 224 or 423 is not available.
When configured as a standalone analyzer, the combiner feature is available.
4.
Additional hardware required. Please refer to chapter 2 of the Service Guide for required service test equipment.
6
For N5242A
Additional information
N5242A-200
N5242A-224
Requires Options 200, 219 and 080
N5242A-400
Recommends Option 080
N5242A-423
Requires Options 400, 419, and 080
N5242A-219
Requires Option 200
N5242A-419
Requires Option 400
N5242AH85
N5242A-010
N5242A-029
Requires one of these options: 219,
224, 419 or 423
N5242A-080
N5242A-082
Requires Option 080
N5242A-083
Requires Option 080
N5242A-084
Requires Options 080 and 083,
requires firmware A.07.50 and above
N5242A-086
Recommend Options 219 or 419,
requires firmware A.08.00 and above
N5242A-551
N5242A-H08
Requires Option 025
N5242A-020
N5242A-021
N5242A-022
Requires Options 224 or 400
N5242A-025
N5242A-1CM
N1966A
N4688A
N4689A
N5242A-897
N5242A-898
N5242A-1A7
N5242A-UK6
N5242A-A6J