Download Print this page

Keysight Technologies PNA-L N5230A Configuration Manual page 31

Pna series microwave network analyzers

Advertisement

For devices with Type-N connectors
Mechanical calibration kits
– 85054B Standard: DC to 18 GHz.
Includes:
00909-60011
Type-N (m) fixed lowband load
00909-60012
Type-N (f) fixed lowband load
85054-60025
Type-N (m) short
85054-60026
Type-N (f) short
85054-60027
Type-N (m) open
85054-60028
Type-N (f) open
85054-60031
Type-N (f) to 7mm adapter
85054-60032
Type-N (m) to 7mm adapter
85054-60037
Type-N (f) to Type-N (f) adapter
85054-60038
Type-N (m) to Type-N (m) adapter
85054-80010
Type-N (f) sliding load
85054-80009
Type-N (m) sliding load
85054-60050
Type-N (f) connector gage
85054-60052
Type-N (f) gage master
85054-60051
Type-N (m) connector gage
85054-60053
Type-N (m) gage master
– 85054D Economy: DC to 18 GHz.
Includes:
85054-60025
Type-N (m) short
85054-60026
Type-N (f) short
85054-60027
Type-N (m) open
85054-60028
Type-N (f) open
85054-60031
Type-N (f) to 7mm adapter
85054-60032
Type-N (m) to 7mm adapter
85054-60037
Type-N (f) to Type-N (f) adapter
85054-60038
Type-N (m) to Type-N (m) adapter
85054-60046
Type-N (m) fixed load
85054-60047
Type-N (f) fixed load
1.
Limits ECal module high frequency to 7.5 GHz.
2.
Special rugged female connector specifically for connecting to the network analyzer
test port, but does not mate with a standard male connector.
Electronic calibration kits
– N4431B Microwave ECal: 300 kHz to 13.5 GHz, 4 ports.
Includes:
Option 020 module with:
N4431-60007 4 x Type-N (f) ECal module
N4431B-xxx mixed-connector options:
Connector type
Port A
option
3.5 mm (f)
101
3.5 mm (m)
102
Type-N 50 ohm
103
(f)
Type-N 50 ohm
104
(m)
1
7-16 (f)
105
1
7-16 (m)
106
– N4432A Microwave ECal: 300 kHz to 18 GHz, 4 ports.
Includes:
Option 020 module with:
N4432-60003 4 x Type-N (f) ECal module
– N4432A-xxx mixed-connector options:
Connector type
Port A
option
3.5 mm (f)
101
3.5 mm (m)
102
Type-N 50 ohm
103
(f)
Type-N 50 ohm
104
(m)
– N4690B Microwave ECal: 300 kHz to 18 GHz, 2 ports.
Includes:
Option M0F module with:
N4690-60001 Type-N (f) to Type-N (m) ECal module
Option 00M module with:
N4690-60002 Type-N (m) to Type-N (m) ECal module
Option 00F module with:
N4690-60003 Type-N (f) to Type-N (f) ECal module
Option 00A adds:
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
2
Cables
Use the test port cables recommended for devices with
7 mm connectors, and 7 mm to Type-N adapters that
are from the 85054B/D Type-N calibration kit (see 7 mm
connector section).
Port B
Port C
Port D
option
option
option
201
301
401
202
302
402
203
303
403
204
304
404
205
305
405
206
306
406
Port B
Port C
Port D
option
option
option
201
301
401
202
302
402
203
303
403
204
304
404
31