Download Print this page

Specifications - Nonin NoninConnect 3245 Instructions For Use

Pulse oximeter with bluetooth smart technology

Advertisement

NoninConnect
Model 3245 with
NoninConnect App:
The NoninConnect Model 3245 Bluetooth pulse oximeter is
designed to be used with the NoninConnect app, a free download
from the Apple iTunes® store, and is compatible with the following
Apple devices (running iOS 8.1 or later):
• iPhone® 4S and newer
• iPad® 3 and newer, all iPad Air®, and all iPad mini™
th
• iPod® Touch 5
edition and newer
The NoninConnect iOS app is not compatible with Windows® or
Android® devices and operating systems.
Integrators, Software Developers, and Telehealth System
Providers: If you want to collect or save data from the
NoninConnect Model 3245 to your medical system or custom-
made software, contact Nonin Medical, Inc. at oem@nonin.com.
You may qualify for direct pricing advantages depending on
volume.
Integration and telehealth support is only available through
Nonin; therefore, register with Nonin as soon as possible to receive
support and important service notifications (e.g., product changes,
common operating system connectivity information).
Contact Nonin for Support: oem@nonin.com or nonin.com/
eHealth.
Warranty
Nonin warrants to the purchaser, for a period of 2 years from the
date of purchase, each NoninConnect Model 3245 exclusive of the
batteries and spring. Nonin shall repair or replace any
NoninConnect found to be defective in accordance with this
warranty, free of charge, for which Nonin has been notified by the
purchaser by serial number that there is a defect, provided
notification occurs within the applicable warranty period. If unable
to repair, Nonin shall replace with a NoninConnect or a comparable
product.
This warranty excludes cost of delivery to and from Nonin. Nonin
reserves the right to charge a fee for a warranty repair request on
any NoninConnect found to be within specifications. This product
is a precision electronic instrument and must be repaired by Nonin
Technical Service. Any sign or evidence of opening the
NoninConnect, field service by non-Nonin personnel, tampering,
or any kind of misuse of the product, shall void the warranty. The
NoninConnect is warranted for consumer use only. All non-
warranty work shall be done at Nonin's standard rates and charges
in effect at the time of delivery to Nonin.
Nonin Medical, Inc.
13700 1st Avenue North
Plymouth, MN 55441-5443, USA
+1 (763) 553-9968
(800) 356-8874 (US and Canada)
Fax: +1 (763) 553-7807
E-mail: info@nonin.com
nonin.com
Download the NoninConnect mobile app from the iTunes

Specifications

Oxygen Saturation Display Range: 0% to 100% SpO
Oxygen Saturation Declared Accuracy: 70% to 100% SpO
Pulse Rate Display Range: 18 to 321 beats per minute (BPM)
Pulse Rate Declared Accuracy Range (A
Low Perfusion Pulse Rate Declared Accuracy Range (A
Temperature:
Operating:
Storage/Transportation: -40 °C to 70 °C / -40 °F to 158 °F
Humidity:
Operating:
Storage/Transportation: 10% to 95% non-condensing
Altitude:
Operating:
Hyperbaric Pressure:
Battery Life:
Operating:
Storage:
Bluetooth Wireless Technology
Information
Bluetooth Compliance: Version 4.0 single mode low energy
Operating Frequency: 2.4 to 2.4835 GHz
Output Power:
Operating Range:
Network Topology: Star - bus
Operation:
Antenna Type:
Modulation Type:
Data Rate:
Data Latency:
Data Integrity:
Data Format:
Quality of Service: NoninConnect uses Bluetooth Smart technology for
Bluetooth Profiles Supported: GATT-based proprietary Nonin profile
Authentication and Encryption: Supported
Encryption Key Size: 128 bits AES (advanced encryption standard)
The Bluetooth® word mark and logo are registered trademarks
owned by Bluetooth SIG, Inc.
Nonin, NoninConnect, and CorrectCheck are trademarks of Nonin
Medical, Inc.
U.S. Patents 5,490,523; 5,792,052; other patents pending.
2
): 20 to 250 BPM ±3 digits
rms
40 to 240 BPM ±3 digits
-5 °C to 40 °C / 23 °F to 104 °F
10% to 95% non-condensing
Up to 10,000 meters / 32,808 feet
Up to 4 atmospheres
Approximately 2,200 spot checks (25 sec. per spot-
check), within 10 meters/32 feet of collector with
streaming data
1 month, with batteries installed.
CAUTION: Remove batteries if the NoninConnect
will be stored for more than 30 days.
TX: +3 dBM
10 meter radius (line of sight)
Slave
NoninConnect
Integrated chip type antenna
Frequency Hopping Spread Spectrum
1 Mbit/second
6 ms
Adaptive Frequency Hopping
24-bit CRC (cyclic redundancy check)
32-bit message integrity check
Sends data packets once per second. Includes a second
counter that allows the host to detect if packets are
missing and the NoninConnect to retransmit.
wireless communications, which allows for reliable
communications in electrically noisy environments,
and transmits physiological data once per second. If
data is lost, NoninConnect will transmit data again
one second later. If the connection is lost,
NoninConnect will change the Bluetooth symbol
from green to white and become available for a
connection in a few seconds.
©2015 Nonin Medical, Inc.
®
store.
±2 digits
2
):
rms
10889-000-01

Advertisement