Siemens SINAMICS G120 Hardware Installation Manual page 73

Power module
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

• Category C3
Table A-1
Model
Category C1 - First Environment
--
Category C2 - First Environment - Professional Use
Filtered Variants
6SL3224-0BE**-*A*0
Category C3 - Second Environment
Unfiltered Variants
6SL3224-0BE**-*U*0
Note
All drives should be installed and commissioned in accordance with the manufacturer's
guidelines and in accordance with good EMC practices.
For further information refer to SIEMENS application note "EMC Design Guidelines".
Power Modules PM240
Hardware Installation Manual, 2006-04-04, A5E00807525B AA
Power Drive System (PDS) of rated voltage less than 1000 V intended for use in the
Second (Industrial) Environment and not intended for use within the First (Domestic)
Environment.
Compliance Table
Remarks
The SINAMICS G120 drives are not intended for use within the Category
C1 Environment.
Drives FSB ... FSF (400 V, 2.2 kW ... 90 kW)
All units (except FSA) with integral filter.
Class A: 25 m screened cable type CY
The FSA power variant (400 V, 370 W ... 1.5 kW) requires either a
footprint filter option (6SE6400-2FA00-6AD0) or additional power-line
filtering at the "system level".
When used in the First (Domestic) Environment this product may cause
radio interference in which case mitigation measures may be required.
All units are available as unfiltered variants.
Drives FSA ... FSF (400 V, 370 W ... 90 kW)
The use of unfiltered drives within an industrial installation is only possible
if it forms part of a system which includes additional power-line filtering at
the "system level" or, alternatively, the use of filtered variants.
A.2 Definition of the EMC Environment and Categories
Appendix
A-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm240