1- Varistor 4- Wire nuts 5- M5 x 12 mm screws 1. Description Camden CX-ED1079L/DL Grade 1 ANSI strikes for cylindrical UL 294 Performance Levels locksets offer the very best strike quality and performance, - Line Security = Level I with three stainless steel faceplates provided.
Page 2
CX-ED1079L/DL ‘Universal’ Electric Strike 4. Installation 1. Prepare the door jamb as per the appropriate drawing. bracket & the lip bracket. Make sure the clearance hole in the spacer aligns with the hole in mounting bracket. 2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts.