4. Installation
1 cm
warm air
electrical connection
Remove the cap from the exhaust port. Retain the
cap for winter storage or for possible returns.
Attach the exhaust hose (included) to the exhaust
port.
Route the hose to the exterior and use a suitable
sealant to seal the opening. The hose may be
shortened as needed. The opening must be10 mm
in diameter.
Make sure the exhaust hose has no kinks or
blockage and that exhaust can escape freely.
4.7
Installing the fuel-cartridge holder
Keep fuel cartridge and all reserve cartridges away
from children. Keep cartridges away from heat and
out of direct sunshine.
Secure fuel cartridge and all reserve cartridges so
that they can not shift.
Make sure that the fuel-cartridge connecting hose is
neither crushed nor kinked.
Do not place fuel cartridges or reserve cartridges in
front of the air intake or outlet!
Place fuel cartridges next to or in front of the unit as
illustrated.
Do not place objects such as reserve fuel cartridges in
front of the air intake or outlet.
23