Automatic Operation - EFOY 1600 User Manual

Automatic charge control
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

5. Operation
Automatic
Charging mode
Automatic
Start phase
Automatic
Standby
Automatic
Please change fuel cartridge
5.2

Automatic Operation

Before connecting to the electrical system, make sure
the unit has been positioned properly and that the
electrical system is protected by fuses (as described
in Chapter 3.4)
Do not operate at temperatures above 40° C or below
- 20° C. If device has been exposed to temperatures
under 0° C without being connected to a battery or with
insufficiently filled fuel cartridge (antifreeze), it must
stand at room temperature for 24 hours before
operating.
Make sure that a full fuel cartridge has been connected.
Automatic operation will begin the moment that you
connect the unit to a battery. The unit will monitor
battery voltage by itself.
The unit charges the battery as needed or assists the
battery in providing output. The second line of the
display will indicate "charging mode" as long as the unit
is providing voltage to the electrical system.
The device goes through a cold start phase of about 20
minutes before reaching its full rated output.
If the battery is sufficiently charged and the unit is not
providing input, the unit will remain in the standby
mode.
Should the device detect a malfunction such as an
empty fuel cartridge, it will shut down and advise you
how to correct the situation. ("Please change fuel
cartridge".) Resume automatic operation using the
reset button after the error has been corrected. (See
also Chapter 7 Troubleshooting).