4. Installation
Power lead
Sensor lead
The charging lines consists of four leads that must be
connected to the battery as follows:
Power lead:
This lead carries current from the fuel cell to the
battery.
Sensor lead:
This lead measures battery voltage.
To minimize current loss in the leads, the following
cross section is recommended, should the battery
charging cable be insufficient:
Length [m]
min. cross section
< 5 m
2.5 mm²
5 – 10 m
4 mm²
10 – 15 m
6 mm²
Option:
Extension sense line 8 m (Art. No. 151 906 005)
Extension Power line 8 m (Art. No. 151 906 006)
Two kinds of electrical connection are possible:
via the central electrical box (Chapter 4.8.1)
directly to the battery (Chapter 4.8.2)