3. Configuration
Environmental conditions
Space requirement (L x W x H) 51 x 35 x 30 cm minimum
Inclination along the direct
axis
Inclination along the
quadrature axis
Operating temperature
Start temperature
Storage temperature
Instrumentation
Operation
Electrical interface
Fuse
Fuel Cartridge
Volume
Weight
Dimensions (L x W x H)
continual:
temporary (<10 min):
continual:
-20 to +40 °C
+5 to +40 °C
+1 to +45 °C
via remote control with four buttons and multilingual display
MNL 4-prong plug
Type Tyco Electronics AMP Universal Mate-N-Lok (Mfr. No.
350779)
G fuse 250V 8.0A M, 5 x 20 mm
M5
5 liter
4.3 kg
19.0 x 14.5 x 28.3 cm
16
35°
45°
20°
M10
10 liter
8.4 kg
23.0 x 19.3 x 31.8 cm