Feeder Terminal
Application selection tables for REF 541, REF 543 and REF 545
functions
.
Table 20: Protection functions
Function
ANSI
device no.
AR5Func
79
2)
CUB1Cap
51NC-1
3)
CUB3Cap
51NC-2
CUB3Low
46
DEF2Low
67N-1
DEF2High
67N-2
DEF2Inst
67N-3
1)
DOC6Low
67-1
1)
DOC6High
67-2
1)
DOC6Inst
67-3
4)
FLOC
21FL
1)
Freq1St1
81-1
1)
Freq1St2
81-2
1)
Freq1St3
81-3
1)
Freq1St4
81-4
1)
Freq1St5
81-5
3)
FuseFail
60
Inrush3
68
2)
MotStart
48
NEF1Low
51N-1
NEF1High
51N-2
NEF1Inst
51N-3
NOC3Low
51-1
NOC3High
51-2
NOC3Inst
51-3
2)
OL3Cap
51C
OV3Low
59-1
OV3High
59-2
2)
PSV3St1
47-1
2)
PSV3St2
47-2
ROV1Low
59N-1
ROV1High
59N-2
ROV1Inst
59N-3
1)
SCVCSt1
25-1
1)
SCVCSt2
25-2
1)
TOL3Cab
49F
2)
TOL3Dev
49M/G/T
UV3Low
27-1
UV3High
27-2
1)
These functions are only supported in the feeder termi-
nal revisions of Release 1.5 or later.
2)
These functions are only supported in the feeder termi-
nal revisions of Release 2.0 or later
.
IEC symbol Description
O-->I
Auto-reclose function (5 shots)
dI>C
Current unbalance protection for shunt capacitor banks
3dI>C
Three-phase current unbalance protection for H-bridge
connected shunt capacitor
Iub>
Phase discontinuity protection
Io>-->
Directional earth-fault protection, low-set stage
Io>>-->
Directional earth-fault protection, high-set stage
Io>>>-->
Directional earth-fault protection, instantaneous stage
3I>-->
Three-phase directional overcurrent protection, low-set stage
3I>>-->
Three-phase directional overcurrent protection, high-set stage
3I>>>-->
Three-phase directional overcurrent protection, instantaneous
stage
FLOC
Fault locator
f1
Underfrequency or overfrequency protection, stage 1
f2
Underfrequency or overfrequency protection, stage 2
f3
Underfrequency or overfrequency protection, stage 3
f4
Underfrequency or overfrequency protection, stage 4
f5
Underfrequency or overfrequency protection, stage 5
FUSEF
Fuse failure supervision
3I2f>
Three-phase transformer inrush and motor start-up current
detector
Is2t n<
Three-phase start-up supervision for motors
Io>
Non-directional earth-fault protection, low-set stage
Io>>
Non-directional earth-fault protection, high-set stage
Io>>>
Non-directional earth-fault protection, instantaneous stage
3I>
Three-phase non-directional overcurrent protection, low-set
stage
I>>
Three-phase non-directional overcurrent protection, high-set
stage
3I>>>
Three-phase non-directional overcurrent protection,
instantaneous stage
3I>3I<
Three-phase overload protection for shunt capacitor banks
3U>
Three-phase overvoltage protection, low-set stage
3U>>
Three-phase overvoltage protection, high-set stage
U1U2<>_1
Phase-sequence voltage protection, stage 1
U1U2<>_2
Phase-sequence voltage protection, stage 2
Uo>
Residual overvoltage protection, low-set stage
Uo>>
Residual overvoltage protection, high-set stage
Uo>>>
Residual overvoltage protection, instantaneous stage
SYNC1
Synchro-check / voltage-check function, stage 1
SYNC2
Synchro-check / voltage-check function, stage 2
3Ith>
Three-phase thermal overload protection for cables
3Ithdev>
Three-phase thermal overload protection for devices
3U<
Three-phase undervoltage protection, low-set stage
3U<<
Three-phase undervoltage protection, high-set stage
3)
4)
REF 541, REF 543, REF 545.
1MRS750443-MBG
These functions are only supported in the feeder termi-
nal revisions of Release 2.5 or later.
This function is only supported in the feeder terminal
revisions of Release 3.5 or later.