Ordering; Language Combinations - ABB REF 541 Product Manual

Feeder terminal
Hide thumbs Also See for REF 541:
Table of Contents

Advertisement

Ordering

Feeder Terminal
The following is to be specified when order-
ing REF 54_ terminals: order number, display
language combination and quantity of feeder
terminals.
Each REF 54_ feeder terminal has a specific
order number that identifies the feeder termi-
REF54_KC127AAAA
A = fixed display, B = external display module
A = without sensor, B = with sensor
Reserved for future use
Auxiliary voltage range of a power supply module and
voltage range of digital inputs
A: power supply: PS1/240 V (Medium) or PS2/240 V
B: power supply: PS1/240 V (High) or PS2/240 V
C: power supply: PS1/48 V (Low) or PS2/48 V
Hardware number: 115, 118, 127, 129, 133
Functionality level: C = Control, B = Basic, M = Multi
Software revision: A, B, C, D, E, F, G, H, K
Feeder terminal type: REF 541, REF 543, REF 545
The functionality level (C) determines the
extent of the selection of function blocks
available for the feeder terminal. For more
detailed information on the separate function
Functionality
Selection of function blocks
level
C (Control)
All control, condition monitoring and measurement functions
All control, condition monitoring and measurement functions, 
B (Basic)
basic protection functions
All control, condition monitoring, measurement and 
M (Multi)
protection functions
In addition, optional functions, such as fault
locator, power quality, capacitor bank protec-
tion and power factor control functions are
available.

Language combinations

Suffix
Language combination
001
English-German
002
English-Swedish
003
English-Finnish
007
English-Portuguese
008
English-Polish
009
English-Russian
010
English-Spanish
012
English-Czech
nal type as well as the hardware and the soft-
ware as described below.
The order number is labelled on the marking
strip on the front panel of the feeder terminal
delivered, e.g. Order No:
REF543KC127AAAA.
U r = 110/120/220/240 V ac;
110/125/220 V dc
digital inputs: U r = 110/125/220 V dc
threshold voltage: U t = 80 V dc
U r = 110/120/220/240 V ac;
110/125/220 V dc
digital inputs: U r = 220 V dc
threshold voltage: U t = 155 V dc
U r = 24/48/60 V dc
digital inputs: U r = 24/48/60/110/125/220 V dc
threshold voltage: U t = 18 V dc
blocks included in each selection, please see
the table Functionality levels, protection
functions on the next page or consult your
relay supplier.
The display language combination (see table
below) is identified by a three-digit suffix in
the software number labelled on the front
panel of the feeder terminal, e.g. Software
1MRS110028-0__.
REF 541, REF 543, REF 545.
1MRS750443-MBG
A050601
43