Feeder Terminal
Table 6: Protection functions
Function
ANSI
IEC
device no.
symbol
AR5Func
79
O-->I
2)
CUB1Cap
51NC-1
dI>C
3)
CUB3Cap
51NC-2
3dI>C
CUB3Low
46
Iub>
DEF2Low
67N-1
Io>-->
DEF2High
67N-2
Io>>-->
DEF2Inst
67N-3
Io>>>-->
1)
DOC6Low
67-1
3I>-->
1)
DOC6High
67-2
3I>>-->
1)
DOC6Inst
67-3
3I>>>-->
4)
FLOC
21FL
FLOC
1)
Freq1St1
81-1
f1
1)
Freq1St2
81-2
f2
1)
Freq1St3
81-3
f3
1)
Freq1St4
81-4
f4
1)
Freq1St5
81-5
f5
3)
FuseFail
60
FUSEF
Inrush3
68
3I2f>
2)
MotStart
48
Is2t n<
NEF1Low
51N-1
Io>
NEF1High
51N-2
Io>>
NEF1Inst
51N-3
Io>>>
NOC3Low
51-1
3I>
NOC3High
51-2
3I>>
NOC3Inst
51-3
3I>>>
2)
OL3Cap
51C
3I>3I<
OV3Low
59-1
3U>
OV3High
59-2
3U>>
2)
PSV3St1
47-1
U1U2<>_1 Phase-sequence voltage protection, stage 1
2)
PSV3St2
47-2
U1U2<>_2 Phase-sequence voltage protection, stage 2
ROV1Low
59N-1
Uo>
ROV1High
59N-2
Uo>>
ROV1Inst
59N-3
Uo>>>
1)
SCVCSt1
25-1
SYNC1
1)
SCVCSt2
25-2
SYNC2
1)
TOL3Cab
49F
3Ith>
2)
TOL3Dev
49M/G/T
3Ithdev>
UV3Low
27-1
3U<
UV3High
27-2
3U<<
1)
These functions are only supported in the feeder termi-
nal revisions of Release 1.5 or later.
2)
These functions are only supported in the feeder termi-
nal revisions of Release 2.0 or later.
REF 541, REF 543, REF 545.
Description
Auto-reclose function (5 shots)
Current unbalance protection for shunt capacitor banks
Three-phase current unbalance protection for H-bridge connected
shunt capacitor
Phase discontinuity protection
Directional earth-fault protection, low-set stage
Directional earth-fault protection, high-set stage
Directional earth-fault protection, instantaneous stage
Three-phase directional overcurrent protection, low-set stage
Three-phase directional overcurrent protection, high-set stage
Three-phase directional overcurrent protection, instantaneous
stage
Fault locator
Underfrequency or overfrequency protection, stage 1
Underfrequency or overfrequency protection, stage 2
Underfrequency or overfrequency protection, stage 3
Underfrequency or overfrequency protection, stage 4
Underfrequency or overfrequency protection, stage 5
Fuse failure supervision
Three-phase transformer inrush and motor start-up current detector
Three-phase start-up supervision for motors
Non-directional earth-fault protection, low-set stage
Non-directional earth-fault protection, high-set stage
Non-directional earth-fault protection, instantaneous stage
Three-phase non-directional overcurrent protection, low-set stage
Three-phase non-directional overcurrent protection, high-set stage
Three-phase non-directional overcurrent protection, instantaneous
stage
Three-phase overload protection for shunt capacitor banks
Three-phase overvoltage protection, low-set stage
Three-phase overvoltage protection, high-set stage
Residual overvoltage protection, low-set stage
Residual overvoltage protection, high-set stage
Residual overvoltage protection, instantaneous stage
Synchro-check / voltage-check function, stage 1
Synchro-check / voltage-check function, stage 2
Three-phase thermal overload protection for cables
Three-phase thermal overload protection for devices
Three-phase undervoltage protection, low-set stage
Three-phase undervoltage protection, high-set stage
3)
These functions are only supported in the feeder termi-
nal revisions of Release 2.5 or later.
4)
This function is only supported in the feeder terminal
revisions of Release 3.5 or later.