VOYAGEUR GRAND AU
10. Replace the strain relief on the power cord in the same
position as before. Locate the indentation on the cord
made by the strain relief. Once replaced, push the
strain relief back into the control plate.
Fiber
Wrapped
Wire
11. Connect the white wire on the power cord into the
fiber wrapped wire on the wire harness. Connect the
black wire on the power cord to the white wire on the
rheostat. Re-attach the green ground terminal to the
control plate.
24
Strain Relief
White Wire
Black Wire
Green
Grounding
Wire
12. Insert the control plate assembly back into the
appliance as shown. Tilt the assembly forward and
then lift up and rotate the bottom towards the front of
the appliance at the same time ensure that the snap
disc holder is properly seated. Secure plate to the
appliance.
Route Wires through Retainer Clip
Replace Screws in Hold Down Bracket
13. Push in the blower and hold down bracket into
appliance matching up the tab on the bracket and
placement slot on the appliance. Secure bracket and
reconnect blower wires (no polarity to worry about)
routing wires through the retainer clip.