Daikin Altherma 08CA Installer's Reference Manual page 55

Hybrid heat pump
Table of Contents

Advertisement

Method
Accessing settings via the breadcrumb in the
menu structure.
Accessing settings via the code in the
overview settings.
See also:
"To access the installer settings" on page 55
"8.1.5 Menu structure: Overview installer settings" on page 78
To connect the PC cable to the switch box
Prerequisite: The EKPCCAB kit is required.
1 Connect the cable with USB connection to your PC.
2 Connect the plug of the cable to X10A on A1P of the switch box
of the indoor unit.
3 Pay special attention to the position of the plug!
2
To access the most used commands
To access the installer settings
1 Set the user permission level to Installer.
2 Go to [A]:
> Installer settings.
To access the overview settings
1 Set the user permission level to Installer.
2 Go to [A.8]:
> Installer settings > Overview settings.
To set the user permission level to Installer
1 Set the user permission level to Adv. end user.
2 Go to [6.4]:
> Information > User permission level.
3 Press
for more than 4 seconds.
Result:
is displayed on the home pages.
4 If you do NOT press any button for more than 1 hour or press
again for more than 4 seconds, the installer permission level
switches back to End user.
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1C – 2018.06
Column in tables
#
Code
3
4
5
To set the user permission level to Advanced end user
1 Go to the main menu or any of its submenus:
2 Press
for more than 4 seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set
otherwise.
To set the user permission level to End user
1 Press
for more than 4 seconds.
Result: The user permission level switches to End user. The user
interface will return to the default home screen.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
1 Go to [A.8]:
> Installer settings > Overview settings.
2 Go to the corresponding screen of the first part of the setting by
using the
and
button.
INFORMATION
An additional 0-digit is added to the first part of the setting
when you access the codes in the overview settings.
Example: [1‑01]: "1" will result in "01".
Overview settings
01
00
00
01
15
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
3 Go to the corresponding second part of the setting by using the
and
button.
Overview settings
01
00
00
01
15
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
Result: The value to be modified is now highlighted.
4 Modify the value by using the
Overview settings
01
00
00
01
20
02
00
04
05
06
08
09
0a
0c
0d
0e
Confirm
Adjust
Scroll
5 Repeat previous steps if you have to modify other settings.
6 Push
to confirm the modification of the parameter.
7 At installer settings menu, press
Installer settings
The system will restart.
OK
Cancel
Confirm
Adjust
Result: The system will restart.
8 Configuration
.
03
00
07
0b
0f
03
00
07
0b
0f
and
button.
03
00
07
0b
0f
to confirm the settings.
Installer reference guide
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma evlq05

Table of Contents