……………………………………..………………………………….. Returns …………………………………..……………………………………… Contact ……………………………………..……………………………………. General tSense for wall mounting measures indoor air carbon dioxide concentration, temperature and relative humidity in rooms. tSense is available with or without color touch display (LCD). The unit can be connected to a Direct Digital Control (DDC) system.
0 - 100%RH See label See label Table 1. Default output configurations of tSENSE Figure 1: Terminal The sensor is supplied with 0 - 10VDC linear outputs for Out(1), Out(2 and Out(3 (see Table 1). Alternative output ranges can be configured with PC software UIP (version 5 or later, see below).
Download software UIP5 Download software UIP (version 5 or higher) at www.senseair.se/products/software/uip-5/ Check for updates Run until… For more information see Help in the UIP5 program. Connection configurations...
Outputs All functions listed on pages 7-9 can be accessed directly from the touch screen. Automatically system-test A full system test is executed automatically at every power-up. Sensor probes are checked constantly during operation against failure by checking valid dynamic measurement ranges.
Error codes and action plans Bit # Error code Error description Suggested action sensor No ability to communicate Try to restart sensor by power Com. error with CO sensor module. OFF/ON. Contact local distributor. sensor measurement error, see Try Background calibration (see fig. 4 measure error Error Status at address 0x1E and 5).
Opening of housing Figure 1 Plint Figure 3 Maintenance tSense is maintenance free. Internal self-adjusting calibration function takes care of normal long term drift. To secure highest accuracy, a time interval of five years is recommended between CO calibrations, unless some special situations have occurred.
Support The quickest way to obtain technical support is via email. Please send all support inquires to support@co2meter.com. Please include a clear, concise definition of the problem and any relevant troubleshooting information or steps taken so far, so we can duplicate the problem and quickly respond to your inquiry.
Contact Us We are here to help! For information or technical support, please contact us. support@co2meter.com (386) 256-4910 ( Technical Support) (386) 872-7665 (Sales) www.co2meter.com Address: CO2Meter, Inc. 131 Business Center Drive Ormond Beach, FL 32174 This product is in accordance with the EMC 2004/108/EC, 92/31/EEG, RoHS 2011/65/EU Including amendments by the CE-marking Directive 93/68/EEC The product fulfils the following demands:...
Need help?
Do you have a question about the tSense and is the answer not in the manual?
Questions and answers