Start Up Instructions - Auto Mode

Note:
Double door models only - switch Humidity/Storage switch (on Eyebrow panel) must be in NORMAL operation or
HIGH HUMIDITY position for refrigerator to operate.
Figure 11.5
Electric Operation
1. Move Thermostat to COLDEST position. Set AUTO - OFF - GAS switch to AUTO. Set DC OFF/DC ON to DC OFF.
2. If 120 volts is active, Eyebrow panel will display AC, indicating refrigerator is operating in 120 volt AC Mode
3. If 120 volts AC is inactive (power failure, disconnected, etc.), Eyebrow panel will display LP, indicating refrigerator
has automatically switched to LP gas mode.
4. If Eyebrow panel displays LP and a red X continuously, the refrigerator has failed to ignite Burner on gas mode.
Restart gas operation by moving AUTO - OFF - GAS switch to OFF and back to AUTO (See steps 3, 4 and 5 under
Gas Mode.). Note: Unit will automatically return to AC when 120 volts AC is restored, even if the unit is locked out
on GAS operation.
5. Move Thermostat to desired setting, usually a mid-setting.

Start Up Instructions - Gas Mode

Note:
Double door models only - Humidity/Storage switch (on Eyebrow panel) must be in NORMAL operation or HIGH HU-
MIDITY position for refrigerator to operate.
Figure 11.6

Gas Operation

1. Move Thermostat to COLDEST. Set AUTO - OFF - GAS switch to GAS. Set DC OFF/DC ON to DC OFF.
2. Eyebrow panel will display LP, indicating LP gas mode. (If LP is not displayed, check for loss of DC supply volt-
age.) Initially, the red X will be displayed for about 5 seconds; after which, sparking will start at the burner and the
red X will shut off.
3. After 10 seconds, the burner should be ignited and operating normally.
4. On the initial refrigerator start-up, it may take longer than 10 seconds to allow air to be purged from the gas line. If
gas does not ignite within 10 seconds, valve will automatically shut off and the red X will be displayed at the
CHECK position.
5. To restart when the X is displayed, move AUTO-OFF-GAS switch to OFF position, then return switch to the GAS
position.
CAUTION
DO NOT CONTINUE TO RESET GAS SWITCH IF THE CHECK INDICATION CONTINUES TO DISPLAY AFTER SEV-
ERAL TRIES. A GAS BUILD-UP MAY OCCUR IN THE BURNER AREA AND RESULT IN A FLASH BACK WHICH MAY
CAUSE PERSONAL INJURY.