B101

12 Volts DC Connection

All refrigerator models require a 12
volt DC supply (even though 2-Way
models are designed to operate on
120 volts AC and gas, a 12 volt DC
control is required to perform control
functions in Gas and AC Modes. The
DC lead connections (1/4" male quick
connects) are at terminals located on
the Power Supply at the rear of the
refrigerator.
One
connection
marked positive (+ ) and the other
negative (-). Correct polarity must be
observed when connecting to the DC
supply. Connect two wires at the re-
frigerator and route to the DC supply.
The distance the current must travel
from the battery to the refrigerator
dictates the AWG wire size to be
used. Should the wire be too small
for the distance, a voltage drop will
result. In the case of 3-Way models,
the voltage drop affects the wattage
output of the system heater and re-
sultant refrigerator performance.
See the wire and fuse chart (Table
1) for the correct wire and fuse size.
Electrical Connection
120 Volts AC
The refrigerator is equipped with a
three-prong
plug for protection
against shock hazard and must be
connected into a recognized three-
prong attachment receptacle. The
free length of cord is 24" and there-
fore is recommended that the re-
ceptacle be located to the left side
of the refrigerator (viewed from rear)
and approximately 12" from the
floor. This allows easy accessibility
through the vent door. The cord
must be routed so as not to come in
contact with the Burner cover, flue
pipe, or any other component that
could damage the cord insulation.
WARNING
DO
NOT
REMOVE
GROUNDING PRONG FROM THE
REFRIGERATOR
AC
CORD.
REMOVAL
OF
PRONG CAN RESULT IN A SEVERE ELECTRICAL SHOCK, AS WELL AS,
VOIDING THE REFRIGERATOR ELECTRICAL CERTIFICATION AND WAR-
RANTY. EXTENSION CORDS ARE NOT RECOMMENDED.
Convertor
is
To Refrigerator
Figure 11.1
0-20'
over 20'
0-20'
over 20'
(CUT)
POWER
Figure 11.2
THIS
Appliance
Connection

Recommended 12 Volt Supply Connection

652, 6052
min. wire
max. fuse
size
size
18 AWG
5 Amp
18 AWG
5 Amp
662, 682, 6062, 6082, 6162,
6182
min. wire
max. fuse
size
size
18 AWG
5 Amp
18 AWG
5 Amp
Green
Ground
Plug
1
12 volt
RV battery
653, 6053
min. wire
max. fuse
size
size
12 AWG
20 Amp
10 AWG
30 Amp
663, 683, 6063, 6083, 6163,
6183
min. wire
max. fuse
size
size
10 AWG
30 Amp
8 AWG
40 Amp
Three
Prong
Plug
This end of the AC
power cord connects to
terminal J-9 neutral and
J-10 hot and the green
ground wire attaches to
the chassis ground.