Eyebrow Removal; Eyebrow Board Removal; Control Voltage Check - Norcold 600 Repair Manual

Power control circuit
Hide thumbs Also See for 600:
Table of Contents

Advertisement

15. If 10 Volts DC is present in the
preceding step, continue by
removing the Eyebrow assem-
bly from the refrigerator by re-
moving the 3 screws as shown
in Figure 11.28.
16. Remove the Eyebrow board
from the Eyebrow assembly
as shown in Figure 11.29.
Do not disconnect the cable
or thermistor from the Eye-
brow board.
17. Set the volt-ohm-meter to
measure + 12 volts DC and
check for 10 volts at R22
and D11 (R23 and D11 for 2-
Way models) as shown in
Figure 11.30.
A. If you do not have 10 volts
the cable is defective.
B. If you have 10 volts and
the AC light is not illumi-
nated the Eyebrow board
is defective.
18. Set the Mode Selector swit-
ches to OFF.
Figure 11.28

Eyebrow Removal

Figure 11.29

Eyebrow Board Removal

Figure 11.30

Control Voltage Check

1
Cable and Thermistor
power connected but
not shown.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

61006000

Table of Contents