Illustrations Showing Normal and Abnormal Conditions of the Mode Selector
Normal Condition
Figure 11.62
Electric Operation
Mode Selector set to AUTO; AC indicated. Refrigerator operating on AC.
Normal Condition
Figure 11.63
Gas Operation
Mode Selector set to AUTO; LP indicated. Refrigerator operating on GAS. 120 volts AC is not supplied to the refrig-
erator.
Normal Condition - Refrigerator off
Figure 11.64
Gas Operation
Mode Selector set to AUTO; CHECK and LP indicated. 120 volts AC is not supplied to the refrigerator and a trial for
ignition failed. The check light will turn on then off and on again during the process.
Normal Condition
Figure 11.65
Gas Operation
Mode Selector set to GAS; LP indicated. Refrigerator operating on GAS.
Normal Condition - Refrigerator off
Figure 11.66
Gas Operation
Mode Selector set to GAS. CHECK and LP indicated a trial for ignition failed. The check light will turn on, then off, and
on again during the process.