General Information And Specification - Norcold 600 Repair Manual

Power control circuit
Hide thumbs Also See for 600:
Table of Contents

Advertisement

B101
OPERATING LIMITS - ALL
MODELS
AC Mode: 132 VAC Max., 108
VAC Min.
15.4 VDC Max., 10.5
VDC Min.
DC Mode: 15.4 VDC Max., 11.5
VDC Min.
Gas Mode: 11" W.C.
15.4 VDC Max., 10.5
VDC Min.
MODELS 652, 653, 6052,
6053 RATINGS
1200 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP14 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 200 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
MODELS 662, 663, 6062,
6063, 6162, 6163 RAT-
INGS
1450 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC

General Information and Specification

MODELS 682, 683, 6082, 6083, 6182, 6183 RATINGS
1500 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
CURRENT DRAWS - 652, 653, 6052, 6053
Automatic Ignition - Less than 500 milliamps or .50 amps
AC Heating Element - 1.5 amps at 110 Volts AC
DC Heating Element - 9.2 amps at 12 Volts DC
CURRENT DRAWS - 662, 663, 682, 683, 6062, 6063, 6082,
Automatic Ignition - Less than 500 milliamps or .50 amps
Interior Light (when equipped) - 300 milliamps (.3 amps)
Humidity Heater - 240 milliamps (.24 amps)
AC Heating Element - 2.7 amps at 110 Volts AC
DC Heating Element - 13.8 amps at 12 Volts DC
1.7 amps at 120 Volts AC
10.7 amps at 14 Volts DC
6083, 6162, 6163, 6182, 6183
2.9 amps at 120 Volts AC
16.1 amps at 14 Volts DC