Description Of Menus - ABB PST30 Installation And Maintenance Manual

Pst series; pstb series
Hide thumbs Also See for PST30:
Table of Contents

Advertisement

U=†††0%
†I=0.0A
Menu
Uin †
Change Password
Select
Back
Keypad is
Active
Motor Temp
Lock
Back
2003-01-30
11:08
SCR Temp
Back
In=0000 Out = 0000
Back
Figure 1: Top level display loop
Figure 2: Top level (start position)
2003-02-05
10:33
Back
Figure 3: Real time clock
Uin
Back
Figure 4: U
status
in
Motor Temp
Back
Figure 5: Motor temperature
7
In = 0000 Out = 0000
Back
Figure 6: Input/outputs
SCR Temp
Back
Figure 7: SCR temperature
Keypad is
Active
Back
Figure 8: Keypad status
Change Password
Select
Back
Figure 9: Change Password
7.8
1SXU 132 021 M0201
Chapter 7
Settings and configuration

7:2 Description of menus

For detailed description of each function, see Chapter 10 " Functions" .
OK
7:2.1 Top level
Back
This level contains information about output voltage, current, heat sink temperature, real time clock
0%
and more. From this menu, the keypad can be locked/unlocked and a password can be set. It is
Back
also possible to enter all top level menus.
60%
Back
Display at start up
When switching on the control voltage, the LCD will first display the text "Hello", and after a few
seconds switch to the Top Level start position, Figure 2.
Real time clock
The real time clock displays the present date and time. To set date, time and display types, see
"Presentation Settings."
U
status
OK
in
The softstarter checks and displays the status of the input voltage (line side).
Motor temperature
0%
The consumed thermal capacity of the motor is displayed. 0% means that the motor is in cold state.
50% means that half the capacity is consumed, etc.
Status of inputs/outputs
The status of the Programmable inputs and outputs is displayed with "0" for not activated or "1" for
activated. The figures have the following functions:
In=0100
In=1000
In=0010
In=0001
Out=1000
Out=0100
Out=0010
Out=0001
SCR Temperature
60%
The temperature of the SCRs in the softstarter is displayed as a percentage of the maximum value.
Keypad status
Information on whether the keypad is locked or unlocked. How to operate, see Chapter 6 "Human-
Machine Interface (HMI)".
Change Password
Menu for changing the password, How to operate, see Chapter 6 "Human-Machine Interface (HMI)".
Start signal high
Stop signal high
In0 high
In1 high
Relay K4 activated
Relay K5 activated
Relay K6 activated
SW V7 activated