4 Set-up
9
Flue pipe wall duct
A = see installation
template (60/100 mm
diameter air/flue pipe)
A = 235 mm
(80/125 mm diameter
air/flue pipe)
Consult the installation template that is supplied to find the
dimension A.
4.5

Minimum clearances

C
C
A
165 mm: Flue pipe, 60/100 mm diameter
275 mm: Flue pipe, 80/125 mm diameter
B
180 mm; optimum approx. 250 mm
C
5 mm; optimum approx. 50 mm
D
500 mm clearance in front of the heat generator
to enable easy access for maintenance work (the
same as a door opening).
4.6

Clearance from combustible components

It is not necessary to maintain a clearance between the
product and components made of combustible materials that
go beyond the minimum clearances (see page).
4.7

Using the installation template

Use the installation template to ascertain the locations at
which you need to drill holes and make breakthroughs.
10
10
Product holder
11
R1 tundish/condensate
siphon connection
12
Flue pipe connection
D
Minimum clearance
4.8

Wall-mounting the product

1.
Check whether the wall has sufficient load-bearing ca-
pacity to bear the operational weight of the product.
2.
Check if the supplied fixing material may be used for
the wall.
Conditions: The load-bearing capacity of the wall is sufficient, The fixing
material may be used for the wall
Wall-mount the product as described.
Install the hanging bracket (1) on the wall.
Hang the product on the product bracket from above
using the suspension bracket.
Conditions: The load-bearing capacity of the wall is not sufficient
Ensure that wall-mounting apparatus on-site has a suf-
ficient load-bearing capacity. Use individual stands or
primary walling, for example.
Do not wall-mount the product if you cannot provide
wall-mounting apparatus with a sufficient load-bearing
capacity.
Conditions: The fixing material may not be used for the wall
Wall-mount the product as described using the adapted
fixing material provided on-site.