E.2

Wiring diagram

Applicability: VUW 346/7-2 (H-GB)
2
1
X40
X51
X32
X90
1
Main PCB
2
Interface PCB
3
Safety thermostat for underfloor heating
4
24 V DC room thermostat
5
Bus connection (digital room thermostat/controller)
6
Outside temperature sensor, wired
7
Temperature sensor in the heating return
8
Temperature sensor in the heating flow
9
Fan
42
X51
X51
X51
X35
Burner
+
24V=
off
RT
BUS
X2
X20
X30
X21
L
N
X12
RT
230Vac
Burner off
RT 24V
X106
eBUS
1
2
3
X41
4
5
6
13
6
5
10
X20
11
4
1
8
15
2
7
3
4
6
16
5
5
1
9
8
17
7
18
14
11
13
X2
3
6
2
20
10
19
14
1
4
X21
3
2
L
X12
N
L
X14
N
RT 230Vac
L
X1
17
N
N
L
L
10
Gas valve
11
Diverter valve
12
Pressure sensor
13
Mass flow-
14
External ignition device
15
Ionisation and ignition electrode
16
Heating pump
17
Main power supply
Installation and maintenance instructions ecoTEC sustain 0020253094_01
3
4
5
6
1
7
2
1
8
2
9
1
M
2
3
4
10
3
1
11
6
M
4
3
1
12
1
4
3
1
13
3
2
3
2
1
15
24V
230V~
16

Hide quick links: