If the unit is being lifted by two persons, ensure your
movements are coordinated during lifting.
If required, get somebody to assist you in this.
4.2

Unpacking the product

1.
Remove the product from its box.
2.
Remove the protective film from all parts of the product.
4.3

Checking the scope of delivery

Check that the scope of delivery is complete and intact.
4.3.1
Scope of delivery
Quant-
Description
ity
Heat generator
1
Bag with accessories:
Hanging bracket
Bag with seals
1
Bag with bolts and rawl plugs
Installation template
Flexible condensate drain pipework
Bag containing the hydraulic connections
Enclosed documentation
1
0020253094_01 ecoTEC sustain Installation and maintenance instructions
4.4

Dimensions

2
3
1
123
65
123
183
11
12
1
Condensate siphon
(condensate discharge
connection, 21.5 mm
diameter)
2
Heating flow connec-
tion, G3/4
3
Heating expansion relief
valve drain pipework
connection, 15 mm
diameter
Set-up 4
4
5
6
7
58 58
8
123
440
9
10
2
4
5
6
7
10
65
123
4
Hot water connection,
G3/4
5
Gas connection, G1/2
6
Cold water connection,
G3/4
7
Heating return connec-
tion, G3/4
8
Drain cock
9

Hide quick links: