8.2.2
Resetting the remaining burner anti-cycling
time
Press and hold the
button for more than three
seconds.
All symbols are shown in the display.
8.3

Setting the maximum heating output

The product's maximum heating output is set to automatic
mode at the factory. If you want to set your own fixed max-
imum heating output, however, you can specify a value un-
der d.00 which equates to the product output in kW.
8.4

Setting the maintenance interval

If you set the maintenance interval, after a configurable num-
ber of burner operating hours, the message that the product
must be serviced appears in the display, together with the
maintenance symbol
.
Use diagnostics code d.84 to set the number of operating
hours until the next maintenance is due (number of op-
erating hours = display value x 10). Guideline values can
be found in the following table.
Guideline value for burner
operating hours until the
Number
next inspection/maintenance
Heat de-
of per-
work is due for an average
mand
sons
operating time of one year
(dependent upon the system
type)
1 ‑ 2
1050 h
5.0 kW
2 ‑ 3
1150 h
1 ‑ 2
1500 h
10.0 kW
2 ‑ 3
1600 h
2 ‑ 3
1800 h
15.0 kW
3 ‑ 4
1900 h
3 ‑ 4
2600 h
20.0 kW
4 ‑ 5
2700 h
3 ‑ 4
2800 h
25.0 kW
4 ‑ 6
2900 h
3 ‑ 4
3000 h
> 27.0 kW
4 ‑ 6
3000 h
The values stated correspond to an average operating time
of one year.
If you do not set a numerical value but do set the symbol
"– – –", the function is not active.
Note
On completion of the set operating hours, you
must set the maintenance interval again.
0020253094_01 ecoTEC sustain Installation and maintenance instructions
Adapting the unit to the installation 8
8.5

Setting the pump output

Applicability: VUW 246/7-2 (H-GB)
OR VUW 286/7-2 (H-GB)
OR VUW 346/7-2 (H-GB)
Conditions: Modulating pump
The product is equipped with a speed-regulated high-effi-
ciency pump, which adjusts independently to the hydraulic
conditions of the heating installation.
If you have installed a low loss header in the heating install-
ation, we recommend switching off the speed regulation and
setting the pump output to a fixed value.
If required, use diagnostics code d.14 to adjust the set-
ting for the operating-mode-dependent pump speed.
Set a diagnostics code. (→ Page 17)
Remaining feed head of the pump
Pump curve
Applicability: VUW 246/7-2 (H-GB)
OR VUW 286/7-2 (H-GB)
B
1
2
40
35
30
25
20
15
10
5
0
0
500
1
PWM 65%
2
PWM 73%
3
PWM 80%
4
PWM 88%
5
PWM 95 to 100%
Pump characteristic line
Applicability: VUW 346/7-2 (H-GB)
B
1
2
3
40
35
30
25
20
15
10
5
0
0
500
1
PWM 65%
2
PWM 73%
3
PWM 80%
3
4
5
6
7
1000
1300
6
Saturation 25 kPa
7
Saturation 17 kPa
A
Throughput in circuit
(l/h)
B
Available pressure
(kPa)
4
5
6
7
1000
1400
4
PWM 88%
5
PWM 95 to 100%
6
Saturation 25 kPa
A
A
23