A desirable installation will produce a total system wiring voltage drop of 3% or less. The lengths shown in Table 3 are one way from the PV modules to
the battery with the 3000i located along the path. Length can be increased inversely proportional to actual PV I
wire lengths could be doubled and still provide the same 3% voltage drop. For 60 cell modules use two wire sizes larger than shown (e.g., 8awg rather
than 12awg) for the wire section between the 3000i and the battery.
WIRE GAUGE
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
➢ CAUTION: Battery and PV compression terminals accept #16 #8 AWG wire and are to be tightened to 15.9 in-
lb (1.80 nm). Temperature Sensor and IPN Network compression terminals accept #2616 AWG wire and are to
be tightened to 2.1 in-lb (0.24 nm). Take care to route wires in a manner that does not place undue strain on the